    1/2 HP SUBMERSIBLE PUMP (TRASH W A TER TYPE) ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .harborfreight.com Copyright © 2005 by Harbor F reight T ools ® . All rights reser ved. No por tion of this manual or any artwor k contained herein ma y be reproduced in any shape or ...

  • Chicago Electric 92481 - page 2

    PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the saf ety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. K eep y our inv oice with this manual. Write the inv oice number on the inside of the front cov er . K eep this manual and in voice ...

  • Chicago Electric 92481 - page 3

    3. Keep bystanders, children, and visitors away while operating the Sump Pump. Distractions can cause you to lose control. ELECTRICAL SAFETY 1. Grounded tools must be plugged into a GFCI (Ground Fault Circuit Interrupter) outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify t ...

  • Chicago Electric 92481 - page 4

    3. A v oid accidental starting. Be sure the circuit suppl ying electrical power is off before plugging in. Plugging in a Sump Pump with the electrical circuit on invites accidents. 4. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the Sump Pump in unexpected situations. 5. Alwa y ...

  • Chicago Electric 92481 - page 5

    SER VICE 1. Sump Pump service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injur y . 2. When servicing the Sump Pump, use only identical replacement parts. Follo w instructions in the “Inspection, Maintenance , And Cleaning” section of this manual. Use ...

  • Chicago Electric 92481 - page 6

    SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 6 V ~ A no xxxx/min. No Load Revolutions per Minute (RPM) Amperes V olts Alternating Current Underwriters Laboratories, Inc. Canadian Standards Association Double Insulated SYMBOLOGY FIGURE B FIGURE A 3-PRONG PLUG 120 V OL T , GROUNDED, ELECTRICAL OUTLET SPECIFIC SAFETY RULES 1. ...

  • Chicago Electric 92481 - page 7

    SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 7 wear nonskid rubber boots when water is on the floor and you must unplug the Sump Pump . Ne v er allo w the Motor to get wet. Make sure the electrical pow er source is a separately fused, grounded, 3-wire type GFCI outlet of 15 AMP capacity . DO NO T REMO VE THE GR OUND PR ONG ...

  • Chicago Electric 92481 - page 8

    SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 8 10. In cold weather , when the Sump Pump is not in use , protect the interior of the Pump from freezing by draining the liquid and pumping a permanent type automobile antifreeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to ...

  • Chicago Electric 92481 - page 9

    SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 9 6. Set the Sump Pump in place, using the accessory Rope (41). Do not raise or lower the Sump Pump by its Power Cord or by its Discharge Hose. (See Figure D.) 4 . Connect the Discharge Hose to the Connector Plug (39) of the Sump Pump , using the Discharge Hose Clamp (40) to secur ...

  • Chicago Electric 92481 - page 10

    SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 10 9 . The Sump Pump will now star t and run continuously until electrical power to the Pump is shut off . 10. When shutting off power to the Sump Pump, always shut off the electrical power to the GFCI outlet fir st. Then, disconnect the Sump Pump’ s P ower Plug from the GFCI o ...

  • Chicago Electric 92481 - page 11

    SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 11 4. Pump Motor runs, but deliver s small amount of water . A. V er tical lift is approaching Sump Pump’ s maximum lift capability . Maximum lift capability is 36 feet. Reduce height of vertical lift. B. Inlet is partially blocked. Check to make sure inlet is clear of debris. ...

  • Chicago Electric 92481 - page 12

    SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 12 with water is recommended. Be sure to flush the system with a neutralizing liquid prior to reuse of the unit. 7. Every two year s: Change the oil in the Sump Pump . The Pump holds approximately 4-3/4 ounces of oil. Always use a quality grade pump oil (i.e., Castrol Magna GC32). ...

  • Chicago Electric 92481 - page 13

    P ARTS LIST SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 13 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts. Part # Description Qt y . Part # Description Qt y . 1 Power Cord/Plug 1 22 Flange 1 2 Screw 2 23 Screw 3 3 Screw 2 24 Oil Seal 1 4 Sprin ...

  • Chicago Electric 92481 - page 14

    ASSEMBL Y DIA GRAM SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 14 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts. 41: ROPE NOT SHOWN. ...

Manufacturer Chicago Electric Category Septic System

Documents that we receive from a manufacturer of a Chicago Electric 92481 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 92481 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 92481
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 92481.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 92481, service manual, brief instructions and user manuals Chicago Electric 92481. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 92481.

A complete manual for the device Chicago Electric 92481, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 92481 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 92481.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 92481 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 92481, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 92481, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 92481 - which should help us in our first steps of using Chicago Electric 92481
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 92481
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 92481 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 92481?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 92481, ask a question using the form below. If a user had a similar problem with Chicago Electric 92481 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)