  • Wasp WLP 4170 CCD - page 1

    Wasp WLP 4170 CCD Programming Guide Please Read Note: The W asp WLP 4170 CCD Scanner is ready to scan the most popular bar codes out of the box. This manual should only be used to make changes in the configuration of the scanner for specific applications. This scanner does not require software or drivers to operate . The scanner enters data as k e ...

  • Wasp WLP 4170 CCD - page 2

    © Copyright W asp T echnologies 2002. All rights reser v ed. V ersion 1.0 No part of this publication may be reproduced or transmitted in any for m or by any means without the written permission of W asp T echnologies . The information contained in this document is subject to change without notice . W asp is a trademark of W asp T echnologies . Al ...

  • Wasp WLP 4170 CCD - page 3

    T able of Contents Chapter 1. Introduction.............................................................................. 1 Chapter 2. Installation................................................................................ 2 Chapter 3. Quick Star t ..............................................................................3 Chapter 4. Bar Co ...

  • Wasp WLP 4170 CCD - page 4

    1 Chapter 1 Introduction Bar coding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity , accuracy, and efficiency in the workplace . Virtually ev ery type of industry is using bar codes to replace k eyboard data entr y . Studies ha ve shown that a proficie ...

  • Wasp WLP 4170 CCD - page 5

    2 1. T urn off your computer . 2. Unplug your PC k e yboard cable and plug the male end (Din 5) of the Wasp WLP 4170 CCD Scanner directly into your PC k e yboard port. Plug your k e yboard cable into the other end (female Din 5) of the the W asp WLP 4170 CCD Scanner. If your ke yboard and PC support a Din 6 connection, use the enclosed Din 5 to Din ...

  • Wasp WLP 4170 CCD - page 6

    3 Y our W asp WLP 4170 CCD Scanner is ready to go . The default settings of the W asp WLP 4170 CCD Scanner ha v e been pre-prog r ammed for the most common bar code configurations . Use the "Setup & Configuration" sections only to customize the Wasp settings. Tip: Use the pre-printed "Bar Code T est Symbols" in Appendix A on ...

  • Wasp WLP 4170 CCD - page 7

    4 Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products . The bars and spaces in each symbol are grouped in such a w a y to represent a specific ASCII character or function. The interpretation of these groups is based on a particular set of rules called symb ...

  • Wasp WLP 4170 CCD - page 8

    5 In order to configure W asp WLP 4170 CCD Scanner, you must familiariz e y ourself with the setup procedures on the following pages . The default settings of W asp WLP 4170 CCD Scanner are identified on each page and clearly mar k ed using an asterisk (*). The default settings have been preprogrammed f or the most common bar code configurations. U ...

  • Wasp WLP 4170 CCD - page 9

    NOTE: Scanning these bar codes returns the scanner to the factory default settings 1. Scan “Begin ” 2. Scan “Default” to restore scanner to default settings 6 Tip: Use this configuration to restore the factory default settings if you are unsure how your scanner has been configured. The 'Factory Default' configuration is very usefu ...

  • Wasp WLP 4170 CCD - page 10

    7 Setup & Configuration —Beep and Dela y Beep V olume Settings 00 None 01 Lowest 02 Low 03 Medium (Default) 04 Medium-High 05 High 06 High-Medium 07 Highest The 'Beep V olume' configuration changes the volume of the audible indicator of the WLP 4170 CCD Scanner . NOTE: For help in configuring these settings, consult the programming ...

  • Wasp WLP 4170 CCD - page 11

    8 Setup & Configuration —Interc haracter Dela y Inter character Delay Settings 00 Slo w est 01 Slo w 02 Default 50 Medium 75 F ast 99 F astest The 'Intercharacter Delay' configuration sets the speed at which the WLP 4170 CCD Scanner sends data. The intercharacter delay should be changed only if the transfer rate cannot be maintained ...

  • Wasp WLP 4170 CCD - page 12

    9 Setup & Configuration —Ke yboard W edg e 00 K eyboard Present* 01 Laptop/No k e yboard The 'Ke yboard W edge' configuration supports options related to managing ke yboard operations . The 'Function Code' option enables/disables support for your ke yboard function k eys. The 'Caps Lock' option toggles the case s ...

  • Wasp WLP 4170 CCD - page 13

    *Default 00 Default* 04 Continuous 10 Setup & Configuration —Scanning Modes Begin Set Scanning Mode Exit The 'Scanning Mode' option controls the trigger and LED settings for the WLP 4170 CCD Scanner. NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Continuous Mode * T rig g er with 10 Sec. Dela ...

  • Wasp WLP 4170 CCD - page 14

    Preamble Data P ostamble 11 Setup & Configuration —Preamble and Postamble *Default The 'Preamble' and 'Postamble' options are used to add prefix and suffix characters to the bar code value . Up to 22 characters may be added for each option separately . Note: T his e xa m pl e i ll ustr ates h ow d at a w il l be f o r m at ...

  • Wasp WLP 4170 CCD - page 15

    12 Setup & Configuration —Code 39 Co de 39 i s v a ri a b le leng t h a n d i s th e most fr equ e n tly use d s ymb olog y in indus t r i a l ba r co d e sys tem s toda y and is e x t e n s i v el y use d wit hi n t he Dep ar tme nt o f D ef e n s e ( D O D ) . T h e p rinci pal f eatur e i s to en cod e m e ssa g es usin g th e full a lp ha ...

  • Wasp WLP 4170 CCD - page 16

    13 Setup & Configuration —Code 39 (cont.) St andar d Co d e 3 9 co n t a i n s o nly 4 3 cha ra ct ers (0- 9 , A-Z , $, / , % , +, - , . , SP A C E ) a nd ca n b e e xtend ed to a 12 8 c ha r a cte r sy mbo lo gy (f u ll A S CI I) by co m bi nin g on e of th e sp e ci al chara c ters ( $, / , %, +) wi th a lette r (A- Z) to f o r m t h e ch a ...

  • Wasp WLP 4170 CCD - page 17

    14 (continued on next page) *Default Setup & Configuration —Code128 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. Co de 1 28 i s v a ri ...

  • Wasp WLP 4170 CCD - page 18

    15 Setup & Configuration —Code128 (cont.) Set Maximum Length Set Minimum Length Begin Format Exit Option Alpha/Numeric Entr y (Back Flap) 64 - Minimum 00 - 64 00* 64 - Maximum 00 - 64 00* Standard 00* UCC/EAN-128 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Co de 128 is t he mo s t f le x i b l e ...

  • Wasp WLP 4170 CCD - page 19

    16 Setup & Configuration —UPC-A On/Off V erify Check Digit Begin T r ansmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable (two digits) 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. UPC-A (Universal Product Code-A) is fixed l ...

  • Wasp WLP 4170 CCD - page 20

    17 Setup & Configuration —UPC-A (cont.) Begin Supplement Digits T r uncate Leading Zero Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The first six digits of the UPC-A bar code are assigned from the Uniform Code Council (UCC).The next five digits are assigned by the manufacturer, and the final di ...

  • Wasp WLP 4170 CCD - page 21

    18 (continued on next page) *Default Setup & Configuration —UPC-E On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. UPC-E (Universal Product ...

  • Wasp WLP 4170 CCD - page 22

    19 *Default Setup & Configuration —UPC-E (cont.) Supplement Digits T runcate Leading Zero Begin Expansion Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The printed value of the UPC-E code is a twelve digit code . The nominal height for the UPC- E bar code is one inch.The reduced size is 80% of th ...

  • Wasp WLP 4170 CCD - page 23

    20 (continued on next page) *Default Setup & Configuration —EAN-13 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-13 (Europea ...

  • Wasp WLP 4170 CCD - page 24

    21 Setup & Configuration —EAN-13 (cont.) NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a 13th digit. The nominal height for the EAN/JAN-8 bar code is one inch.The reduced ...

  • Wasp WLP 4170 CCD - page 25

    22 (continued on next page) *Default Setup & Configuration —EAN-8 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. The EAN/JAN-8 is fixed ...

  • Wasp WLP 4170 CCD - page 26

    23 *Default Setup & Configuration —EAN-8 (cont.) Supplement Digits T r uncate Leading Zero Begin Expansion Exit Option Alpha/Numeric Entr y (Back Flap) None 00* 2 digits 01 5 digits 02 2 / 5 digits 03 or None Disable 00* Enable 01 Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. Th ...

  • Wasp WLP 4170 CCD - page 27

    24 Setup & Configuration —Code 93 On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 Disable 00 Enable (two digits) 01* Disable 00* Enable 01 64 - Minimum 64 - 00 00* 00 - Maximum 00 - 64 00* NOTE: For help in configuring these setting ...

  • Wasp WLP 4170 CCD - page 28

    25 Setup & Configuration —Interleaved 2 of 5 *Default Begin On/Off V erify Check Digit T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. I n t e rl e a v ed 2 o f 5 i s a v ...

  • Wasp WLP 4170 CCD - page 29

    26 Setup & Configuration —Codabar *Default On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00* Enable 01 Disable 00* Enable 01 64 - minimum 64 - 00 00* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Cod ...

  • Wasp WLP 4170 CCD - page 30

    27 *Default Setup & Configuration —Codabar (cont.) Set Minimum Length Start/Stop T ype Begin Start/Stop T ransmission Exit Option Alpha/Numeric Entr y (Back Flap) 00 - Maximum 00 - 64 00* ABCD/ABCD 00* abcd/abcd 01 ABCD/TN*E 02 Abcd/tn*e 03 Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ...

  • Wasp WLP 4170 CCD - page 31

    28 Setup & Configuration —MSI Plesse y On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 Disable 00* Mod 10 01 Mod 10/10 02 Mod 11/10 03 Disable 00* Enable 01 64 - Minimum 64 - 00 00* 00 - Maximum 00 - 64 00* NOTE: For help in configu ...

  • Wasp WLP 4170 CCD - page 32

    29 Setup & Configuration —PDF417 On/Off Begin Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. PDF417 is a 2D variable length symbology that can encode virtually any letter, number, or character . Each character consists of 4 bars and 4 ...

  • Wasp WLP 4170 CCD - page 33

    30 Code 39* Interleav ed 2 of 5 Codabar* Code 128* MSI/Plesse y Code 93* Setup & Configuration —Bar Code T est Symbols—Appendix A Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan. Use the 'Bar Code Symbologies' configuration beginning on page 14 to enable specific sym ...

  • Wasp WLP 4170 CCD - page 34

    31 UPC-A* UPC-E* UPC-E w/5 digit supplement UPC-E w/2 digit supplement UPC-A w/2 digit supplement UPC-A w/5 digit supplement Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Default ...

  • Wasp WLP 4170 CCD - page 35

    EAN/J AN 13* EAN/J AN 13 w/2 digit supplement EAN/J AN 13 w/5 digit supplement 3 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Def ault ...

  • Wasp WLP 4170 CCD - page 36

    EAN/JAN 8* EAN/JAN 8+5 w/5 digit supplement EAN/JAN 8 w/2 digit supplement PDF417 33 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Default ...

  • Wasp WLP 4170 CCD - page 37

    34 Setup & Configuration —WLP 4170 CCD Specifications MODEL WLP 4170 OPTICAL Scanning Width 3.2 in (120 mil) Depth of Field 0 to 3 in (0 to 200 mil) Scan Rate 200 scans / second ELECTRICAL Light Source 660 nm red visible LED Sensor 2,048 pixel CCD arr a y Operating V oltage +5 VDC ± 0.25V Current Consumption Standby 100 mA @ 5 VDC / Sleep 25 ...

  • Wasp WLP 4170 CCD - page 38

    35 W asp Bar Code products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at W asp Bar Code's option, with reasonable promptness after ...

  • Wasp WLP 4170 CCD - page 39

    43 C 44 D 45 E 46 F 47 G 48 H 49 I 4A J 4B K 4C L 4D M 4E N 4F O 50 P 51 Q 52 R 53 S 54 T 55 U 56 V 57 W 58 X 59 Y 5A Z 5B [ 5C 5D ] 5E ^ 5F _ 60 ` 61 a 62 b 23 # 24 $ 25 % 26 & 27 ‘ 28 ( 29 ) 2A ★ 2B + 2C 2D - 2E . 2F / 30 0 31 1 32 2 33 3 34 4 35 5 36 6 37 7 38 8 39 9 3A : 3B ; 3C < 3D = 3E > 3F ? 40 @ 41 A 42 B 36 ASCII Code T able ...

  • Wasp WLP 4170 CCD - page 40

    0 1 2 3 4 5 6 7 8 9 A B C D E F FINISH BACK COVER BAR CODES ...

Manufacturer Wasp Category Scanner

Documents that we receive from a manufacturer of a Wasp WLP 4170 CCD can be divided into several groups. They are, among others:
- Wasp technical drawings
- WLP 4170 CCD manuals
- Wasp product data sheets
- information booklets
- or energy labels Wasp WLP 4170 CCD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Wasp WLP 4170 CCD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Wasp WLP 4170 CCD, service manual, brief instructions and user manuals Wasp WLP 4170 CCD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Wasp WLP 4170 CCD.

Similar manuals

A complete manual for the device Wasp WLP 4170 CCD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Wasp WLP 4170 CCD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Wasp WLP 4170 CCD.

A complete Wasp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Wasp WLP 4170 CCD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Wasp WLP 4170 CCD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Wasp WLP 4170 CCD, that we can find in the current document
3. Tips how to use the basic functions of the device Wasp WLP 4170 CCD - which should help us in our first steps of using Wasp WLP 4170 CCD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Wasp WLP 4170 CCD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Wasp WLP 4170 CCD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Wasp WLP 4170 CCD?

Use the form below

If you did not solve your problem by using a manual Wasp WLP 4170 CCD, ask a question using the form below. If a user had a similar problem with Wasp WLP 4170 CCD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)