    March, 1985 R ev. 3, 4/0 2 ©1989- 2002 Fl uke C orporati on. All Rights Reserv ed. P rinte d in U.S .A. All produc t nam es are tr adem arks of thei r res pectiv e compa nies Instruction Sheet 80PK-1 WARNING TO AVOID ELECTRI CAL SHOCK, DO NOT USE THIS PROBE WHEN VO LTAG ES EXCEED ING 24 V AC R MS OR 60 V DC A RE PRESEN T. THE PROBE TI P IS ELEC TR ...

  • Fluke 80PK-1 - page 2

    Output: 25 ° C (77 ° F) = 1 .00mV (ref erenc e junction at 0 ° C) Seebeck Coefficient: 25 ° C (77 ° F) = 40.50 µ V / ° C Measuremen t Time (Time Constan t): 2 s econds (for air at room temperature and one atmosphere of press ure m ovi ng with a veloc ity of 6 5 ft / sec) Maximum Vo ltage: 24V ac rms or 60V dc maximum for proper safe operati ...

  • Fluke 80PK-1 - page 3

    juncti on compens ati on. Ac c uracy of the temperature measurin g instrum ent must be considered along with the 80PK-1 acc uracy specificat ion in order to determine the overal l accuracy of the combina tion. Temperature Limitations The 260 ° C continuos temperature rati ng of t he 80PK-1 is primarily det erm i ned by the Teflon insulati on. The ...

  • Fluke 80PK-1 - page 4

    b. Use an interface agent (s uch as silicone grease) between the thermoc oupl e probe and the surface you are measuring. c. Use a thermal epoxy to attac h the thermocouple. 2. When measuring higher than ambient t emperatures, adjust the connect i on between the probe and the surfac e until you obt ai n the highes t temperat ure reading. To ensure a ...

Manufacturer Fluke Category Thermometer

Documents that we receive from a manufacturer of a Fluke 80PK-1 can be divided into several groups. They are, among others:
- Fluke technical drawings
- 80PK-1 manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 80PK-1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 80PK-1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 80PK-1, service manual, brief instructions and user manuals Fluke 80PK-1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 80PK-1.

Similar manuals

A complete manual for the device Fluke 80PK-1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 80PK-1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 80PK-1.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 80PK-1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 80PK-1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 80PK-1, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 80PK-1 - which should help us in our first steps of using Fluke 80PK-1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 80PK-1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 80PK-1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 80PK-1?

Use the form below

If you did not solve your problem by using a manual Fluke 80PK-1, ask a question using the form below. If a user had a similar problem with Fluke 80PK-1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)