  • Pentair 472645 - page 1

    Pentair Commercial Pool Heaters Ordering P/N 472645 MegaTherm™ MT — 500-5000 MBTU/h PowerMax™ PM — 500-2000 MBTU/h ...

  • Pentair 472645 - page 2

    2 © 2006 Pentair W ater P ool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins A ve ., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles A ve ., Moor park, CA 93021 • (805) 553-5000 T rademarks and disclaimers P owerMax, MegaTherm and the Pentair Commercial P ool and Spa logo are trademar ...

  • Pentair 472645 - page 3

    3 MegaTherm MT Standard Features 500-5000 .................................. 4 Model Nomenclature .............................................. 4 Code Options .......................................................... 4 Features and Opti ons ............................................. 5 Special Codes/ Options .................................... ...

  • Pentair 472645 - page 4

    4 S t andard Features MegaTherm MT (500-5000) MODEL MT -POOL REVISION P - PUMP 500-1825 A- 2000-5000 HEAT EXCHANGER C -GLASS LINED/COPPER N -GLASS LINES/CU-NI K -BRONZE/COPPER S -BRONZE/CU-NI VERSION 1-8 TUBE B-10 TUBE C-18 TUBE FUEL N -NATURAL P -PROPANE IGNITION 04- SPARK 110V 09- SPARK 24V (500-1825) 18- SPARK 24V (2000-5000) 16- STND. PILOT SIZ ...

  • Pentair 472645 - page 5

    5 500-1825 2000-2450 2800-5000 Ignition Systems System 4 N/A N/A O System 9 S N/A N/A System 16 O O O System 18 N/A S S Firing Mode On/Off S S S Motorized On/Off (FM & Minnesota Code only) N/A N/A O Gas Trains Manual Valve S S S Redundant Safety Valve S S S Main Gas Regulator S S S Manual Firing Valve O O O Pilot Gas Regulator S S S Leak Test V ...

  • Pentair 472645 - page 6

    6 • Automatic bypass • ASME 160 psi working pressure heat exchanger • ASME “H” stamp • Flanged water connections • Glass-lined cast iron headers • External header gaskets • 75 psi (817 kPa) ASME rated pressure relief valve • Flow switch • T emperature and pressure gauge • Multiple operating gas valve/pressure regulators • ...

  • Pentair 472645 - page 7

    7 St andard Models - 4th Character Code Code 500 750 1000 1250 1500 1750 2000 Base model with std on/of f control, std copper P tube HX (requires heat exchanger option) with automatic by-pass, and normal water pump mounted Fuel Options - 9th character code Natural Gas N n/c n/c n/c n/c n/c n/c n/c Propane Gas P n/c n/c n/c n/c n/c n/c n/c CONFIGURA ...

  • Pentair 472645 - page 8

    P/N 472645 Rev A - 05/22/06 Litho in U .S.A ...

  • Pentair 472645 - page 9

    Commercial Pool Heater Parts Sizes 210,000 - 5,000,000 BTU/h P/N 472645 Heater Name Model Sizes Doc. No. MegaTherm - Commercial Pool Heater MT 500-1825 472643 MegaTherm - Commercial Pool Heater MT 2000-5000 472644 PowerMax - Commercial Pool Heater PM 500-2000 472642 ...

  • Pentair 472645 - page 10

    2 Using “Genuine Pentair” parts will ensure accurate replacement and warranty coverage. Installation and Operation Manuals for current products are available on-line at http://www.pentairpool.com Our Commitment We believe the availability of factory authorized replacement parts is an essential component of customer service. We strive to provide ...

  • Pentair 472645 - page 11

    3 Part No. Description Model Size Part No. Description Model Size MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT Old style AP before April 1999, New style after April 1999 Sizes 500,000 - 1,825,000 BTU/h GAS SYSTEM BURNER TRAYS See listing in MegaTherm HH, PH, VW, PW and IW for common components. 1052 ...

  • Pentair 472645 - page 12

    4 Part No. Description Model Size Part No. Description Model Size MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 10449521 Hi Tension Lead (orange/red wire from ignition ctrl to pilot lead) ....... both .. 16 ...

  • Pentair 472645 - page 13

    5 10667706 Baffle, HX (8 tube outdoor) (28 req) ......................................... both .. 1200 ........................ 10667707 Baffle, HX (8 tube outdoor) (28 req) ......................................... both .. 1430 ........................ 10667708 Baffle, HX (8 tube outdoor) (28 req) ......................................... both .. ...

  • Pentair 472645 - page 14

    6 Part No. Description Model Size Part No. Description Model Size MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 CROSS REFERENCE FOR NO LONGER AVAILABLE P/N’S 10364504 Inlet/Outlet Header, (Service Glassed ...

  • Pentair 472645 - page 15

    7 Part No. Description Size Part No. Description Size MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT Sizes 2,000,000 - 5,000,000 BTU/h MAIN GAS SYSTEM L2002200 Orifice Nat, #20 DMS ................................................................ L2006100 Orifice Nat, #23 DMS .......................... ...

  • Pentair 472645 - page 16

    8 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 Part No. Description Size Part No. Description Size 20011002 Lower Base Assy ........................... 2450I/2200E ..................... 20011003 ...

  • Pentair 472645 - page 17

    9 T2007000 Tile (9.25") ..................................... 3600,4050, ....................................................... 4000,4500I ........................ T2007002 Tile, Pyro, Front & Rear, Right see T2007000 models (AP) ....................................................... T2007100 Tile (14.75") .......................... ...

  • Pentair 472645 - page 18

    10 10417400 Flange, 4" cast iron (2 req) ............ all ...................................... 10416100 Return Header (double pass) ........ all ...................................... 20021100 Return Header, Bronze (double pass) ................................. all ...................................... 10416700 Return Header (single pass) ...

  • Pentair 472645 - page 19

    11 20013801 Draft Hood Relief Baffle, Right .................................................. 20013802 Draft Hood Relief Baffle, Right .................................................. 20013803 Draft Hood Relief Baffle, Right .................................................. 20013804 Draft Hood Relief Baffle, Right .............................. ...

  • Pentair 472645 - page 20

    12 20069400 Baffle Center Strap ........................ 3200/5000 ......................... 20015101 Flue End Assy, Left ....................... all ...................................... 20015102 Flue End Assy, Right ..................... all ...................................... 20016702 Flue Panel Rear ............................. 2450I/2200E ...

  • Pentair 472645 - page 21

    13 NATURAL PRO PANE NAT URAL P ROPANE NATURAL P ROP ANE 0 - 2000 L0050700 L 2002200 L2011300 L2006400 L2002600 A #44 #20 #35 #24 #3 7 L 2001 - 3000 L0032900 L2006100 #54 #23 L2002500 L2006700 L20027 00 T #36 3001 - 4000 L0 032600 L00640 0 #26 #38 I #45 #24 T 4001 - 5000 L2006700 L002600 L20 07000 L2002800 #26 #37 #27 #3 8 U 5001 - 6000 L0 050200 L2 ...

  • Pentair 472645 - page 22

    14 T T T T T ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT (AP After April 1999) Sizes 500,000 - 1,825,000 (Cement Tile) When ordering tiles: Assembly number is for all tiles. Part numbers shown at front of unit are the same for rear tiles. ...

  • Pentair 472645 - page 23

    15 T T T T T ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT (AP Units Before April 1999) Sizes 500,000 - 1,825,000 (Pyro Tile) When ordering tiles: Assembly number is for all tiles. Part numbers shown at front of unit are the same for rear tiles. ...

  • Pentair 472645 - page 24

    16 T ile Assemblies - MT Sizes 2,000,000 - 5,000,000 (Pyro Tile) I=Indoor, E=Outdoor ...

  • Pentair 472645 - page 25

    17 Part No. Description Size Part No. Description Size PowerMax PM PowerMax PM PowerMax PM PowerMax PM PowerMax PM Sizes 500,000 - 2,000,000 BTU/h COMBUSTION CHAMBER COMPONENTS 5C2600 Chamber Assy, Left, Bottom ......... 500-2000 ........................... 5C2200 Chamber Assy, Right, Bottom ....... 500-2000 ........................... 5C2003 Chamb ...

  • Pentair 472645 - page 26

    18 ELECTRICAL COMPONENTS E2105500 Diagnostic Board ........................... 500-2000 ........................... R2027700 Relay, 10A, for Diagnostic Board (uses 3) .......................................... 500-2000 ........................... RE0013000 Flow Switch .................................... 500-2000 ........................... E210480 ...

  • Pentair 472645 - page 27

    19 PowerMax PM PowerMax PM PowerMax PM PowerMax PM PowerMax PM Part No. Description Size 5C3002 Plate, Cover, Filter ......................... 500-1000 ........................... 15C3002 Plate, Cover, Filter ......................... 1250-2000 ........................ 5C3502 Plate, Cover, Wiring ...................... 500-2000 .................... ...

  • Pentair 472645 - page 28

    © 2006 Pentair W ater P ool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins A ve ., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles A ve ., Moor park, CA 93021 • (805) 553-5000 T rademarks and disclaimers P owerMax, MegaTherm and the Pentair Commercial P ool and Spa logo are trademar k ...

Manufacturer Pentair Category Swimming Pool Heater

Documents that we receive from a manufacturer of a Pentair 472645 can be divided into several groups. They are, among others:
- Pentair technical drawings
- 472645 manuals
- Pentair product data sheets
- information booklets
- or energy labels Pentair 472645
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pentair 472645.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pentair 472645, service manual, brief instructions and user manuals Pentair 472645. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pentair 472645.

Similar manuals

A complete manual for the device Pentair 472645, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pentair 472645 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pentair 472645.

A complete Pentair manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pentair 472645 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pentair 472645, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pentair 472645, that we can find in the current document
3. Tips how to use the basic functions of the device Pentair 472645 - which should help us in our first steps of using Pentair 472645
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pentair 472645
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pentair 472645 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pentair 472645?

Use the form below

If you did not solve your problem by using a manual Pentair 472645, ask a question using the form below. If a user had a similar problem with Pentair 472645 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)