Manual New Buck Corporation 94NC

29 pages 0.74 mb
Download

Go to site of 29

Summary
  • New Buck Corporation 94NC - page 1

    MODEL 94NC NON-CA T AL YTIC UNIT Buck Stove FEATURES PREPARATIONS INSTALLATION OPERATION MAINTENANCE SAFETY FIREPLACE INSER T & FREEST ANDING SAFETY NOTICE IF THIS HEATER IS NOT PROPERLY INSTALLED, A H OUSE FIRE MAY RESULT. FOR YOUR SAFE TY, FOLLOW THE INSTALLA TION INSTRUCTIONS. CONTACT THE AUTHORIT Y HAVING JURISDICTION (SUCH AS MUNICIPAL BUI ...

  • New Buck Corporation 94NC - page 2

    ...

  • New Buck Corporation 94NC - page 3

    T ABLE OF CONTENTS Important Inst ructions ............................................................................ 2 SECTION I: In troducti on ....................................................................... 3 T ype of wood and lo ading procedu res ................................................... 3 Parts List ........................ ...

  • New Buck Corporation 94NC - page 4

    INST ALLA TION, OPERA TION, AND MAINTENANCE INSTRUCTIONS MODEL 94NC BEFORE INST ALLING YOUR NEW BUCK ST OVE, READ THE ENTIRE INSTRUCTION MANUAL IMPOR T ANT INSTRUCTIONS  The New Buck Corp. non-catalytic Model 94NC has been tested and listed by ITS, (Warnock Hersey) to ANSI/UL Standa rds, :UL1482(2000) :UL1482(2006) :UL1482 (2010) Standard for ...

  • New Buck Corporation 94NC - page 5

    SECTION I INTRODUCTION Your new MODEL 94NC is a non- catalytic unit designed to meet the most stringent em issions standards without use of a catalytic combustor. This effect is achieved through use of secondary air which is mixed with primary air in unit’s firebox. For peak performance, we suggest the use of natural seasoned hard wood, loading w ...

  • New Buck Corporation 94NC - page 6

    EP A COMPLIANCE ST A TUS The Model 94NC heater meets U.S. Environmen tal Protection Agency’s Emission limit s for non- cat wood heaters sold after July 1, 1992. Under specific conditions this heater has been shown to deliver heat at rates ranging from ap proximately11,900to42,000BTU/hr for the Model 94NC. MODEL 94NC WOOD ST OVE 1. Secondary air t ...

  • New Buck Corporation 94NC - page 7

    SECTION II MASONR Y INSER T INST ALLA TION The Model 94NC may be installed using an all masonry fireplace built in accordance with Uniform Building Code and National Fire Prot ection Association (NFPA). The first step in this type of installation is to determine accepta bility of fireplace and chimney for use with a woodstove. Both construction and ...

  • New Buck Corporation 94NC - page 8

    POSSIBLE TOOLS NEEDED FOR INST ALLA TION If you decide to install your own stove, there are several hand tools you may need to do the job. If you do not already have them, they are r eadily available at mo st hardware stores. Caulking gun Large adjustable wrench (may not be needed) Drop cloths or newspapers Vacuum cleaner or whisk broom Flashlight ...

  • New Buck Corporation 94NC - page 9

    OPTION (B) Figu re 3 , REMOVE DAMPER OR WIRE IT OPEN BLOCK-OFF PLATE OR DAMPER ADAPTER SEAL TRIM PANELS WITH INSULATION OR HIGH TEMPERATURE CAULK STAINLESS STEEL CHIMNEY CONNEC- TOR MUST EXTEND 1’ PAST THE BLOCK-OFF PLATE OR TO THE FLUE LINER NOTE: Follow installation instruction with Direct Connection Kit. (Kit sold separately) SAFETY NOTICE If ...

  • New Buck Corporation 94NC - page 10

    INST ALLA TION PROCEDURE (Use a chimney connector or a Listed Direct or Positive Connect) (See Pag e 6). POSITIONING HEATER When positioning heater, the fo llo wing conditions MUST be met! (See Figure 5). 1. The front of flue opening must be pos itioned BEHIND rear edge of the lintel to ensure p roper draft. (See Figure 5). 2. Center heater in fire ...

  • New Buck Corporation 94NC - page 11

    8. Obtain outer trim kit provided with insert kit and slip over top and sides of trim panels.(See Figure 7). (Top ends of outer trim may need to be trimmed to fit). 9. Using insulation provided, peel a n d stick to back of panels overlapping fireplace dimensions by 1" on each side and top. (See Figure 8). 10. Next using high heat silicone or f ...

  • New Buck Corporation 94NC - page 12

    The connector and/or chimney should be inspect ed at least once a m onth during the heating season to determine if a creosote buildup has occurred. CAUTION THE UNIT IS PAINTED WITH A SPECIALLY FORMULATED HIGH TEMPERATURE PAINT THAT CURES DURI NG THE FIRST TWO OR THREE FIRINGS. YOU MAY NOTICE A SLI GHT SMOKING EFFECT AND AN ODOR OF BURNING PAINT WHE ...

  • New Buck Corporation 94NC - page 13

    SECTION IV RESIDENTIAL FREEST ANDING INST ALLA TION Select an installation location that will gi ve best air flow from front of heater to remainder of home. PREP ARING STOVE FOR INST ALLA TION 1. Inspect unit for any obvious physical damage. 2. Plug power cord into a 115V AC outlet to test motor. “Do not run power cord under unit or in high traff ...

  • New Buck Corporation 94NC - page 14

    Chimney This model is designed for connection to an y listed 2100º UL103 HT chimneys and parts. Follow chimneys manufacturer's instructions carefully. This room heater must be converted to (1) a chimney complying with the requirements for Type HT chimneys in the Standard f or ch imneys, Factory-Built, Residential, Type and Building Heating Ap ...

  • New Buck Corporation 94NC - page 15

    Step (b): Calculate R of proposed system. 4” brick of C=1.25, therefor e Rbrick = 1/C = 1/1.25 =0.80 1/8” mineral board of K = 0.29, therefore Rmin.bd. =1/029 x0.125 = 0.431 Step (c): Compare proposed system R of 1.23 1 to specified R of 0.893. Since proposed system R is greater than required , th e system is acceptable. Definitions: Install in ...

  • New Buck Corporation 94NC - page 16

    Page 14 a) Minimum 3.5-in thick brick masonry all framed into combustible wall with a minimum of 12-in brick separation from c lay liner to combustibles . The fireclay li ner shall run from outer surface of brick wall to, but not beyond , the inner sur face of chimney flue liner an d shall be firmly cemented in place. b) Solid-insulated factory-bui ...

  • New Buck Corporation 94NC - page 17

    B. Wall Exit Into Metal Tee-Box 1. Mark plumb line on wall directly be hind center of h eater. (See Figure 11). NOTE: When using 24# ga. minimum blue or black steel pipe, maintain 18" between pipe and ceiling. NOTE: Floor protector must be under horizont al pipe exit (See Fi gure 13. Page 19). 2. Place vertical portion of heater pipe a nd elbo ...

  • New Buck Corporation 94NC - page 18

    3. Measure up so there will be at least 1/4" rise per foot of horizontal connector pipe, maintaining clearances to ceiling as noted in (Figure 12). This will give you center of hole for chimney penetration. 4. After locating center of penetration, inst all tee-box and chimney as per chim ney manufacturer's specifications. 5. Connect chimn ...

  • New Buck Corporation 94NC - page 19

    Connectors may pass through walls or partitions constructed of com bustible material if connector is: (a) Either listed for wall pass-through or is routed through a device listed for wall pass- through and is installed in accordance with conditions of listing. (b) Selected or fabricated in accordance with conditions and clearances as stated in NFPA ...

  • New Buck Corporation 94NC - page 20

    FINAL CHECK 1. Recheck specified clearances. 2. Re move all foreign material from firebox area. 3. Open primary air control. Primary Air Controls: The primary air inta ke control is located at right bottom side of hearth. It is operated by m oving the handle out to open (to allow air into the firebox) or in (to control or close o ff) air into the f ...

  • New Buck Corporation 94NC - page 21

    CLEARANCES FOR MODEL 94NC MINIMUM CLEARANCES TO COMBUSTIBLES RESIDENTIAL SINGLE W ALL CONNECT OR Figure 13 A B C D E F G H MODEL 94NC 25" 8" 10.5" 8" 8" 6" 20" 10” NOTE: All clearances are to combustibles usin g single wall pipe, mi nimum floor protector . Minimum floor protection under unit m ust have an R-valu ...

  • New Buck Corporation 94NC - page 22

    SECTION VI WOOD HEA TER SAFETY Certain safety hazards are inhe rent in any wood heater installa tion. You should be aware of these so that a safe and proper installation can be made. 1. FAULTY CHIMNEY: An older masonry chim ney should be thoroughly checked to be sure there are no holes or weak spots which coul d allow sparks or hot gases to escape. ...

  • New Buck Corporation 94NC - page 23

    SECTION VII OPERA TION This section of the manual is to help you get maximum efficiency and maximum sm oke (particulate) reduction from your heater. If you should experien ce any difficulty or have any questions concerning your heater, contact your dealer for assistance. NOTE: The manufacturer recommends that for maxi mum performance burn natural s ...

  • New Buck Corporation 94NC - page 24

    ROOM AIR BLOWER OPERA TION Your heater is equipped with a room air blower. For opera tion and wiring see figure 14. For your convenience your heater is equipped with a rheostat with which you are able to select air flow. The auto and manual switch will allow you to select th e position at which thermostat will function. Auto-position: After heater ...

  • New Buck Corporation 94NC - page 25

    SECTION VIII TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Sluggish Heater Obstruction in chimney Check for and remove obstruction Improperly sealed trim kit or direct connect kit (a) Check trim kit gask eting seal to fireplace and gasket as necessary to seal unit. Gasket under front bottom of stove if needed. (b) Check seal if using direct conne ...

  • New Buck Corporation 94NC - page 26

    TROUBLESHOOTING (Continued) PROBLEM POSSIBLE CAUSE SOLUTION High fuel consumption Improper regulation of draft or inlet air (a) Close inlet air control as much as possible to maintain desired heat output (b) Check gaskets, reinstall fiberglass gasketing round doors and glass as necessary Improper door fitting Check door gasket, check adjustment of ...

  • New Buck Corporation 94NC - page 27

    REPLACEMENT P AR TS FOR MODEL 94NC Description Part Number 1. Primary Air Handle PS 94NC040 2. Door Handle Assembly PA 910096 3. Door Latch PC 910098 4. Door Handle Washer PO 91WASH 5. Front Door Bushing PO 910102 6. Door PC 912651 7. Carling Fan Auto/Man Switch PE RC211RB 8. Thermostat 110° Disc PE 400132 9. Power Cord PE 400240 10. Strain Relief ...

  • New Buck Corporation 94NC - page 28

    NEW BUCK CORPORA TION (NBC) "LIMITED W ARRANTY" FOR THE BUCK ST OVE PLEASE READ THIS W ARRANTY CAREFULL Y PRODUCTS COVERED This warranty covers the new Buck Stove h eating unit, so long as it is owned by the original purchaser, including optional and standard accessori es purchased at the sa me tim e, subject to terms, limitations, and co ...

  • New Buck Corporation 94NC - page 29

    If for any reason you are dissatisfied with the suggested procedures, you may contact us in writing at: New Buck Corporation Customer Service Departm ent P. O. Box 69 Spruce Pine, NC 28777 CONDITIONS AND EXCLUSIONS (A) Replacement of parts may be in the form of new or fully reconditioned parts, at NBC's option. (B) There is no other express wa ...

Manufacturer New Buck Corporation Category Stove

Documents that we receive from a manufacturer of a New Buck Corporation 94NC can be divided into several groups. They are, among others:
- New Buck Corporation technical drawings
- 94NC manuals
- New Buck Corporation product data sheets
- information booklets
- or energy labels New Buck Corporation 94NC
All of them are important, but the most important information from the point of view of use of the device are in the user manual New Buck Corporation 94NC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals New Buck Corporation 94NC, service manual, brief instructions and user manuals New Buck Corporation 94NC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product New Buck Corporation 94NC.

A complete manual for the device New Buck Corporation 94NC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use New Buck Corporation 94NC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of New Buck Corporation 94NC.

A complete New Buck Corporation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual New Buck Corporation 94NC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the New Buck Corporation 94NC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the New Buck Corporation 94NC, that we can find in the current document
3. Tips how to use the basic functions of the device New Buck Corporation 94NC - which should help us in our first steps of using New Buck Corporation 94NC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with New Buck Corporation 94NC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of New Buck Corporation 94NC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning New Buck Corporation 94NC?

Use the form below

If you did not solve your problem by using a manual New Buck Corporation 94NC, ask a question using the form below. If a user had a similar problem with New Buck Corporation 94NC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)