Manual Teledyne 3000TA

19 pages 0.7 mb
Download

Go to site of 19

Summary
  • Teledyne 3000TA - page 1

    Teledyne Analytical Instruments QUICKS T AR T GUIDE M O D E L 3 0 0 0 T A T ra ce Oxygen Analyzer ...

  • Teledyne 3000TA - page 2

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments ...

  • Teledyne 3000TA - page 3

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 3 GETTING S T ARTED This Quickstart Guide is designed to get you s et up and ope rating your Teledyne An a lytical Instruments Analyzer quickly. It shortcuts the details so you can install and use your new analyzer with a minimum of fuss. This Quicksta rt Guide should be used in conjunct ...

  • Teledyne 3000TA - page 4

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 4 • Left & Right Arrows Select between functi ons currently displayed on the VF D screen. • Up & Down Arrows Increment or decrement values of functions currently displayed. • Enter Advances VFD display to the next screen in a series or re turns to the Analyze scree ...

  • Teledyne 3000TA - page 5

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 5 • Analog Output C onnecti on: Terminals for current and volt age a n alog output signals. • Digital Input Terminals: Termi n als for connecti ng d igital input signals. • Alarm Connections: 2 concentration alarms and 1 system alarm. • Calibration Contact : To notify e xternal e ...

  • Teledyne 3000TA - page 6

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 6 SETUP AND INS T ALL Mount the Ana lyzer The Model 3000T A is for indoor use in a general purpose are a. It is NOT for hazardous environme nts of any type. It is design ed fo r f lush p anel m ount ing. Us e t he fou r m ount ing h ole s— on e i n each corn er of t he r igid ...

  • Teledyne 3000TA - page 7

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 7 4. If using remote calibra tion feature: • Connect zero gas to t he Z ERO IN port. • Connect span ga s to the SP AN IN port. 5. Otherwise, c a li b ra t io n ga se s m u st b e T e e' d i nt o t h e s a m p l e i n le t wi t h a p p r o p ri a t e v a l ve s . 6. Regulate the ...

  • Teledyne 3000TA - page 8

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 8 • Connect primary input power: Insert the power cord into the power cord rece ptacle. • Install the fuse: Fuses are not installed at the fac tory. Be sure to install the proper fuse as par t of installati on. Place small scre wdr iver in notch, and pry cover off, as shown. ...

  • Teledyne 3000TA - page 9

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 9 • Connect Range ID Contacts: There a re four ded icated Range ID relay contacts on the rear panel. The first three ranges are assigned to relays in ascending order. Range 1 ID— Low range Range 2 ID— Medium ra nge Range 3 ID— High range Range 4 ID—Air Cal Ra nge (25%). • Net ...

  • Teledyne 3000TA - page 10

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 10 9. With t h e O-ring in place, align the guide pin with the hole on the cell holder. Then, with the hol d er, lift cell into the cell block. 10. Push the gate on the cell block down so that the slots on the side of the gate engage the locati ng screws on the side of the block ...

  • Teledyne 3000TA - page 11

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 11 BASIC OPER A TION Once the a naly zer has been installed, it can be configured for your application. Prior to using the instrument you m ust : • Calibrate t he instrument • Define the analysis r anges and choose whether to use autoranging or a fixed range. • Set ala rm setpoints ...

  • Teledyne 3000TA - page 12

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 12 A vailab le Functions The six function butt ons are used to control the analyzer. Some functi ons have submenus that allow additional choices as s hown below. Any function ca n be sel ected at any time by pressing the appropriate button (unless password restrictions appl y). ...

  • Teledyne 3000TA - page 13

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 13 Password Protection If a password is assigned, then setting the following system parameters can be done only after t he passw ord is entered: span and zero settings, alarm setpoints, analysis range definitions, switching bet ween autoranging and manual overri de, setting up an auto-ca ...

  • Teledyne 3000TA - page 14

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 14 TRAK/HLD Auto — Cal PSWD Logou t M ore • Use the ◄► arrow keys to scroll the blin king over to PSWD , • Press Enter to select the password function. Eithe r the default TE TAI password or AAAAA place holders for an existing password will appear on screen depending o ...

  • Teledyne 3000TA - page 15

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 15 Auto Mode Zero Calibration • Press Zero to enter the zero function mode. • Use the ▲▼ arrow keys to toggle between AUT O and MAN zero settling. Stop when AUT O appears blinking. Zero : Settling: AUTO <ENT> To B e gin • Press Enter to begin zeroing. #### PP M Zero Slop ...

  • Teledyne 3000TA - page 16

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 16 Span Calibration Make sure an appropriate span gas is connecte d to the sample port. Auto Mode Spanning: • Press Span to enter the span function. • Use the arrow keys to toggle between AUTO and MAN span settling. Stop when AUT O appears, bli nking on the display. Span: Se ...

  • Teledyne 3000TA - page 17

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 17 Calib. Holding time Cal hold: 5 min • Press Enter key to continue. Span Val : 000008.00 <ENT>Span <UP>Mod # • Press ▲ (<UP>) to permit modification ( Mod # ) of span value. • Use the arrow keys to enter the oxygen c o ncentration of t he span gas you ar e usi ...

  • Teledyne 3000TA - page 18

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 18 • Latc hing? Ltch–Y/N (Yes/No). • To change any of th e alarm parameters, use the ◄► arrow keys to move the blinkin g over to the specific par ameter. • Use the ▲▼ arrow keys to change t he va lue of the parameter. Holding down the key speeds up the inc rem en ...

  • Teledyne 3000TA - page 19

    Model 3000TA Quickstart Guide Teledyne Analytical Instruments 19 • Use the ▲▼ arrow keys to switch from AUTO t o FX/L O , FX/MED , or F X /HI to set the instrument on the desired fixe d range (low, medium , or h igh). L—100 M—1000 H—10000 Mode—FX/LO —or— L—1 M—10 H—100 Mode—FX/MED —or— L—1 M—10 H—100 Mode—FX/HI ...

Manufacturer Teledyne Category Respiratory Product

Documents that we receive from a manufacturer of a Teledyne 3000TA can be divided into several groups. They are, among others:
- Teledyne technical drawings
- 3000TA manuals
- Teledyne product data sheets
- information booklets
- or energy labels Teledyne 3000TA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Teledyne 3000TA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Teledyne 3000TA, service manual, brief instructions and user manuals Teledyne 3000TA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Teledyne 3000TA.

Similar manuals

A complete manual for the device Teledyne 3000TA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Teledyne 3000TA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Teledyne 3000TA.

A complete Teledyne manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Teledyne 3000TA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Teledyne 3000TA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Teledyne 3000TA, that we can find in the current document
3. Tips how to use the basic functions of the device Teledyne 3000TA - which should help us in our first steps of using Teledyne 3000TA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Teledyne 3000TA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Teledyne 3000TA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Teledyne 3000TA?

Use the form below

If you did not solve your problem by using a manual Teledyne 3000TA, ask a question using the form below. If a user had a similar problem with Teledyne 3000TA it is likely that he will want to share the way to solve it.

Copy the text from the picture