    The V oice Gateway User Manual IPE 1000 Series version : 1.0 update date : 2004/1/2 A RT Dio Company Inc. ...

  • ArtDio IPE 1000 - page 2

    2 T erminology ¾ FXS interface: A Foreign Exchange S t ation (FXS) in terface is us ed to conn ect s to a st anda rd telephon e, fax machine, trunk side of PBX, or to other FXO interfaces. It will supply ring, volt age, and dial tone. So it is very important not to conn ect th e FXS interface to the wr ong device that are not listed above, it will ...

  • ArtDio IPE 1000 - page 3

    3 T able of Content s 1.INTRODUCTION .................................................................................................................. 6 1.1 Functions of the PBX V oIP Gateway ......................................................................................................................... 6 1.1.1 Rem oves the heterogeneou s ...

  • ArtDio IPE 1000 - page 4

    4 3.8 Adding A New Slave De vice to the Gr oup ............................................................................................................... 30 4. BASIC CONFIGURA T ION ............................................................................................ 35 4.1 System Console Modes .......................................... ...

  • ArtDio IPE 1000 - page 5

    5 4.4.5 Cal l Status ................................................................................................................................................................... 72 4.5 Management Inter faces ............................................................................................................................... ....... ...

  • ArtDio IPE 1000 - page 6

    6 1.Introduction This guide explains how to configure the PBX V oIP gateway using the system console commands and web management interface. This man ual is designed fo r t he technicians respo nsible for configuring the gateway . The candidates should have techni cal networking ba ckground and PBX V oIP gatew ay experience. They must also have a wo ...

  • ArtDio IPE 1000 - page 7

    7 1.1.3 Foreign Exchange Advant ages The toll-free advanta ge ca n also be extended to a ccess remote PSTNs. A Company can set up a PSTN line in a remote of fice in a foreign country . Domestic users can then access the remote PSTN through the PBX gateway while p aying local or long distance pho ne rates instead of Inte rnational phone rates. 1.1.4 ...

  • ArtDio IPE 1000 - page 8

    8 1.1.5 T elecommuter Application In a company , some of the people are asked to trav el around or work at home. With PBX gateway , can provide the application to allow the user t ake a smal l box travel around or inst all in home, the user can receive the phone that call to his desk wherever . ...

  • ArtDio IPE 1000 - page 9

    9 2. Basic Applications of the PBX VoIP Gateway 2.1 Internal Calls The V oIP Gateway is desig ned to be the tie trunk of the PBX, which means that when two or more PBXs are tied with V oIP connections, the extension line on the remote PBX will func tion as an extension of the local PBX. The following graphic is an example of this concept. The user ...

  • ArtDio IPE 1000 - page 10

    10 2.2 Calling From St ations T o Remote PSTNs PBX V oIP gateways that have the FXO interface are abl e to make phone calls from extensions of the PBX to remote PSTN users through an IP network. The following exampl e demonstrates how a user on extension "209" at an of fice in Shenzhen , can communicate with a user in T aipei with the pho ...

  • ArtDio IPE 1000 - page 11

    11 Fig 2 Example of calling from PSTN to internal stations 2.4 T ransit Calls From PSTNs to Remote PSTNs The following example is designed fo r teleco mmuters or administrative users that need to access the remote PSTN in another office. This ap plication allows the user to call from a local PSTN to a remote PSTN through the PBX V oIP gateway . T o ...

  • ArtDio IPE 1000 - page 12

    12 Fig 3 Example of making transit calls fr om PSTNs to remote PSTNsQuick Installation ...

  • ArtDio IPE 1000 - page 13

    13 3. Quick Installation 3.1 Quick S t art 1. Plug in the Ethernet Cable, Null Modem cable and switch on the device to begin the configuration procedure. 2. Configure the IP Address, subnet mask, Default Gateway to make the device reachable from the network. 3. Configure the device’ s prefix . 4. Decide the role (master o r slave ) of the device ...

  • ArtDio IPE 1000 - page 14

    14 Fig 4 The maste r is responsible for maintainin g the membe r list Fig 5 When a new Slave is added to the group re gist rar . ...

  • ArtDio IPE 1000 - page 15

    15 Fig 6 The maste r updates the new member list and sends it to each member Fig 7 The master will synchroni ze the member information with each member . Device Role MUST Parameters Master  Prefix  Group ID  MAC address of Slave devices Slave  Prefix  Group ID  IP addre ss of Master Device Note 1 If a slave has successfully join e ...

  • ArtDio IPE 1000 - page 16

    16 3.3 Working Under a NA T Networking Environment IP addre sses are limited; b ecause of this, not all devic es on the Internet can have their own public IP address. An application is av ailable that allows users to use a private IP address by utilizing a NA T (Network Address Tran slation) server . When the packets ar e sent out from the local ar ...

  • ArtDio IPE 1000 - page 17

    17 some settings do not need an adju stment on the NA T server , such as the SMC barricade  The master must have a publi c IP address  Only one slave device with a pr ivate IP address may be installed on each NA T domain. This means that cascading to increase the density of cha nnel s by using private IP addresses is not suppor ted  Some I ...

  • ArtDio IPE 1000 - page 18

    18 3.4 Utilizing QoS advant ages The PBX voice gateway is equipped with QoS capabilities. This provides hi gher priority for voice than dat a from the LAN. However you must inst all the device according to the following diagram in ord er to give voice output a higher priority than data output from a LAN. The "T o W AN" Ethernet port on th ...

  • ArtDio IPE 1000 - page 19

    19 Fig 10 Diagram showing utilization of e mbed ded QoS functions while stacking t he devices 3.4.1 Connectors and LED Indicators W ARNING: Please ensure that the cables that will be connected to the F XS interfaces on the PBX V oIP Front Panels s gateway are not connected to any power sou rce ("0" voltage). 19-inch model Fig 1 1 19 -in c ...

  • ArtDio IPE 1000 - page 20

    20 1 FXS and 1 FXO Model 2 FXS and 2 FXO Model 4 FXS Model 4 FXO Model Fig 14 7-inch model Rear Panel ...

  • ArtDio IPE 1000 - page 21

    21 Connectors Description Connectors T ype Description To W A N 10/100 Ethernet RJ45 with MDI-X onnect to the Ethernet port Designed to c on the router . To L A N 10/100 Ethernet RJ45 with MDI nnect to one of the LAN’ s Designed to co HUB/Switch port s. EIA-232 DB-9 DTE a VT100 terminal or Can be connected to system console. The terminal should b ...

  • ArtDio IPE 1000 - page 22

    22 3.5 Initial configuration of the Gateway Y ou must configure the Gateway to allow you to dist inguish multiple PBX V oIP gateways from each other . Y ou may also want to configure a password fo r the gateway to prev ent any unauthorized access. 3.5.1 Using the System Console The following process sh ows how the host name and pass word can be con ...

  • ArtDio IPE 1000 - page 23

    23 To configure the password for read and write privileges The privileges are divided into read-o nly and re ad-write with a different password for each privilege. After you have issued this comm and, yo u will then be asked to enter this password each time you enter privileged mode. Any combination of cha racters and digits are allowed with a maxi ...

  • ArtDio IPE 1000 - page 24

    24 3.6 IP Configuration Y ou must configure the IP address, subnet mask and de fault gateway so that the PBX V oIP Gateway is able to connect to the IP network. Si nce the device provides a 10BASE-T/ 100BASE-TX Ethernet i nterface with a default auto-negotiation setting, it s hould work like a plug-and -play device; therefore a manual configuration ...

  • ArtDio IPE 1000 - page 25

    25 PBX GATEWAY#configure Enter configuration commands, one per line. End with CTRL/Z PBX GATEWAY (config)# Step 3: A ssi gn the IP address and the subnet mask Command: PBX GATEWAY (config)# ip address < ip-address > < subnet-mask > PBX GATEWAY (config)#ip address 203.79.238.144 255.255.255.128 System must then be restarted PBX GATEWAY ( ...

  • ArtDio IPE 1000 - page 26

    26 Using Phone Set Interface Step 1: T ake the handset of f the phone Step 2: Dial the PRO G Access Code after hearing the dial tone (default is ## ) Step 3: Enter the Password (defa ult is 0000) Step 4: Enter code "02" . Step 5: Enter the IP address as "203","*","79","*","238","*&quo ...

  • ArtDio IPE 1000 - page 27

    27 PBX GATEWAY (config)# Step 3: Enable DHCP Mode PBX GATEWAY (config)#ip state dhcp PBX GATEWAY (config)# Step 4: Back to Privileged Mode PBX GATEWAY (config)#exit PBX GATEWAY# Step 5: Rest art the system to enable DHCP mod e. Afte r the restart comman d is issued, the system will prompt for a confirmation. PBX GATEWAY# restart This command restar ...

  • ArtDio IPE 1000 - page 28

    28 3.7 Configuring the Master Device Using the System Consol e Interface o r T elnet Step 1: Enter Privileged Mode PBX GATEWAY> enable Password: ****** PBX GATEWAY# Step 2: Enter Routing Mod e PBX GATEWAY# routing PBX GATEWAY (routing)# Step 3: Confi gure this devi ce as the master gateway by setting its value to 0.0.0.0 3 Command: PBX GATEWAY ( ...

  • ArtDio IPE 1000 - page 29

    29 agent. Reset system, [Y]es or [N]o? Yes Step 7: Confi guri ng the Pref ix for the gateway The prefix for the gateway should be assigned by the network administrator and configured to the device. It will be carried in the rout ing messages to notify the master device of it s prefix for other gateways to route its calls. Command: PBX GATEWAY (rout ...

  • ArtDio IPE 1000 - page 30

    30 and "#" as the ending pro m pt. Y ou will then hear the confirmation tone. Step 8: Enter code "05" to begin the group ID config uratio n. Step 9: Enter the group ID as "2009" and "#" as the ending prompt. Y ou will then hear the confirmation tone. System must now be restarted Step 10: Enter code "98&q ...

  • ArtDio IPE 1000 - page 31

    31 Password: ****** PBX GATEWAY# Step 2: Enter Routing Mod e PBX GATEWAY# routing PBX GATEWAY (routing)# Step 3: Create an entry for this slave gat eway Command: PBX GATEWAY (routing)# slave add <ffffff-ffffff, the MAC address of this Slave Device> PBX GATEWAY (routing)# slave add 000362-000004 PBX GATEWAY (routing)# show slave 0001. 00-03-62 ...

  • ArtDio IPE 1000 - page 32

    32 Using the System Consol e Interface o r T elnet on the Slave Device Step 1: Enter Privileged Mode PBX GATEWAY> enable Password: ****** PBX GATEWAY# Step 2: Enter Routing Mod e PBX GATEWAY# routing PBX GATEWAY (routing)# Step 3: Confi gure this devi ce as the master gateway Command: PBX GATEWAY (routing)# master_ip 211.21.40.180 PBX GATEWAY (r ...

  • ArtDio IPE 1000 - page 33

    33 The prefix of the gateway shoul d be assigned by the network admin i strato r and configured to the device. It will be carried in the rout ing messages to notify the master device of it s prefix for other gateways to route its calls. Command: PBX GATEWAY (routing)# prefix <prefix for this gateway> PBX GATEWAY (routing)# prefix 33 PBX GATEW ...

  • ArtDio IPE 1000 - page 34

    34 confirmation tone. System must now be restarted Step 10: Enter code "98" then press "1" and "#" as the ending prompt . Y ou will then hear the confirmation tone and the system will restart automatically . Ste p 1 1 : Enter code "09" to begin configuring for prefix for this gateway . Step 12: Enter the pref ...

  • ArtDio IPE 1000 - page 35

    35 4. Basic Configuration 4.1 System Console Modes EXEC Privileged Configuration Console Channel exit exit line console channel end end exit/end configure Routing Routing exit/end Code code exit end disable enable login exit 4.2 System Management The following general information is needed to configure the system with the appropriate routi ng infor ...

  • ArtDio IPE 1000 - page 36

    36 4.2.1 Information-Web Management ...

  • ArtDio IPE 1000 - page 37

    37 Category Entry Description Dat a Ty p e Range Host Name Name of the gateway for the system administrator to distingui sh this gateway from others. It will also be used as a prompt in the system console. RW Any string up to 48 charac ters in length can be used. Y ou may input a total of 255 characte rs. However , once a length of 48 is reached, a ...

  • ArtDio IPE 1000 - page 38

    38 Category Entry Description Dat a Ty p e Range T ime Current T ime RW hh:mm:ss System Rest art Resta rt Mode This pull-down menu allows you to select the restart mode: None : No system restart wi ll be issued: Cold St art : The sy st em will restart from the beginning. Th e running code will be decompressed from the flash memory and initiate all ...

  • ArtDio IPE 1000 - page 39

    39 4.2.3 Registration-Web Interface Category Entry Description Dat a Ty p e Range Current Device Role Slave: This device is currently configured as a slave gateway . Master: This device i s currently configured as a master gateway . RO Registration As Master / As Slave Name of the gateway for the system administrator to distinguish this gateway fro ...

  • ArtDio IPE 1000 - page 40

    40 As a Master Category Entry Description Dat a Ty p e Range Group ID The Group ID for PBX V oIP Gateway RW 0~2147 483 647 Act As Master Prefix The prefix is the code used to route a call to this gateway RW 1~9999 Capacity The allowed cap acity for slave entries RO 31 not including the Master Quantity Current regist ered slaves RO 0~31 Slave List T ...

  • ArtDio IPE 1000 - page 41

    41 As a Slave Category Entry Description Dat a Ty p e Range Group ID The Group ID for the PBX V oIP Gateway RW 0~2147 483 647 Prefix The code used to route a call to this gateway RW 1~9999 Master IP Address The IP Address of the Master gateway RW XXX.XXX.X XX.XXX Act As Slave Group ID Hold Ti m e 4 The Hold T ime for the Group ID in the device when ...

  • ArtDio IPE 1000 - page 42

    42 4.2.4 Registration Information- Console Interface Category Entry Console Mode Console Command Dat a Ty p e Group ID Routing group_id < number > RW Prefix Routing prefix < number > RW Master IP Routing master_ip <xxx.xxx.xxx.xxx> RW Add Slave Routing Slave add <ffffff-ffffff> RW Delete Slave Routing Slave del <ffffff-ff ...

  • ArtDio IPE 1000 - page 43

    43 Category Entry Description Dat a Ty p e Range Tr a n s i t Call Function Enable or disable T ransit Calls RW Enable/ Disable Tr a n s i t Call W aiting Ti m e The timer for sending a warnin g tone to the caller while a transit call is taking place. RW ( 1~ 60 ) mi n (Default=3) CDR Report Enables or disables CDR report output 6 RW Enable/ Disabl ...

  • ArtDio IPE 1000 - page 44

    44 4.2.6 Configuration Inform ation- Console Interface Category Entry Console Mode Console Command Dat a Ty p e Tr a n s i t Call Function Routing transit_call < enable/disable > RW CDR Report Routing cdr 8 < enable/disable > RW Greeting Mode Routing greet_mode < default/recoding > RW Auto Attendant Routing auto_attn < enable/d ...

  • ArtDio IPE 1000 - page 45

    45 4.2.7 Numbering Plan-Web Interface ...

  • ArtDio IPE 1000 - page 46

    46 Category Entry Description Dat a Ty p e Range Country Code The Country Code where this gateway is located. Used for receiving incoming calls fro m other countries RW 1~999 Area Code The Area Code where this gateway is located. Used for receiving incoming calls f rom other areas RW 1~999 Extension Digits The number of digits for the PBX lines RW ...

  • ArtDio IPE 1000 - page 47

    47 Category Entry Description Dat a Ty p e Range Cut Through While access the FXO port s, in order to dial out directly bypa ss to the FXS ports of this device without listen to the Greeting Message that recorded in the device, then press this Access Code. (FXO to FXS) RW [0~9,*,#][0~9], example "*12345" (Default is Blank) Softkey Access ...

  • ArtDio IPE 1000 - page 48

    48 4.2.8 Numbering Plan Information- Console Interface Category Entry Console Mode Console Command Dat a Ty p e Country Code Code country < 1-999 > RW Area Code Code area < 1-999 > RW Circuit Connect Code circuit_connect < Access Code > RW Cut_Through Code Cut_Through < Access Code > RW Dial Code Code Dial_code < internat ...

  • ArtDio IPE 1000 - page 49

    49 4.2.9 International Code-Web Interface Category Entry Description Dat a Ty p e Rang e International Access Code (Outbound) Dial Code The number that is add ed before the Country code, Area Co de a nd subscriber's telephone n umber to gain International Call access. Applies to PBX Gateway with FXO interface only . RW 0-999 Capacity The numbe ...

  • ArtDio IPE 1000 - page 50

    50 Delete Entries The Access Codes that you are going to remove from the Code List WO [0~9], example "012", "002" Note 4 The Inbound International Access Code is used to analy ze the number that the gateway is receiving from analog voice interfac es . The received numbers are carried with this specified Inbound Internation al Ac ...

  • ArtDio IPE 1000 - page 51

    51 4.2.11 Long Dist ance Code-Web Interface Category Entry Description Dat a Ty p e Range Long Dist ance Access Code (Outbound) Dial Code The number plus the Area Code and the subscriber's telep hone number . Applies to PBX Gateway with FXO interface only . RW 0-999 Capacity The number of In-bound International Access Code entries that are all ...

  • ArtDio IPE 1000 - page 52

    52 4.2.12 Long Dist ance Code Information- Console Interface Category Entry Console Mode Console Command Dat a Ty p e Long Dist ance Access Code (Outbound) Dial Code Code dial_code long_distance < 1-999 > RW Code List Code show ac_summary RO Add Entries Code long_distance add <1-999> RW Long Dist ance Access Code (Inbound) Delete Entrie ...

  • ArtDio IPE 1000 - page 53

    53 4.2.13 Routing T able-W eb Interface Category Entry Description Dat a Ty p e Range Capacity The number of allowed en tries used for routing a call to the PSTN via the gateway 15 RO 20 Quantity The number of routing entries that are currently configured on the gateway RO 0-20 Route List List of route entries with their correspondi n g route cost ...

  • ArtDio IPE 1000 - page 54

    54 Delete Entries T o delete a routing entry WO 0-999999 Note 7 For example, if a gate way is inst alled in th e USA and is assigned to be the routin g gate way for all calls in the group to Ott awa, Canada, the routing entry for this example will be 1613 with cost 1 . Y ou will also need to specify the outbound Interna tion al Access Code 01 1. So ...

  • ArtDio IPE 1000 - page 55

    55 4.2.15 Pin Code Assignment-W eb Interface Category Entry Description Dat a Ty p e Range Capacity The allowed amount of entries for PIN codes that are used when making transit calls via the gateway RO 32 Quantity The number of PIN codes that are currently configured on thi s gateway RO 0-32 Code List The list of PIN codes that are configured on t ...

  • ArtDio IPE 1000 - page 56

    56 4.2.16 Pin Code Assignment- Console Interface Category Entry Console Mode Console Command Dat a Ty p e Code List Routing show pin RO Add Entries Routing pin add <0-99999999> <1-99> WO Routing Configuration Delete Entries Routing pin del <0-99999999> WO ...

  • ArtDio IPE 1000 - page 57

    57 4.2.17 T opology-W eb Interface Category Entry Description Dat a Ty p e Range To t a l Members The number of members in the same g roup RO T opology Member List The list of gateways in the sam e group. Displays the co rre sponding prefix that is specified for each gateway 16 RO 4.2.18 T opology- Console Interface Note 9 There is no similar funct ...

  • ArtDio IPE 1000 - page 58

    58 4.2.19 Route Search-Web Interface Category Entry Description Dat a Ty p e Range IP Address If the Prefix that is specified in the previous section cannot be found, the IP addres s of that gateway will be displayed. Otherwise, "Not Found" will be displayed. RO Route Search Route Entry The Route Entry that will be searched 17 WO 4.2.20 R ...

  • ArtDio IPE 1000 - page 59

    59 4.2.21 MGCP Configuration - Web Interface Category Entry Description Dat a Ty p e Range Call Agent S tatus The status whethe r this voice gateway connect to call agent or not RO Out of Service, In Service Number of channel suppor ted The number of channel s that registered with call agent RW 0, 4, 8 Gateway ID The name of this gate way that regi ...

  • ArtDio IPE 1000 - page 60

    60 4.3 TCP/IP Configuration The TCP/IP can be configured throug h the system consol e and the W eb manag ement interface. The re are two ways to obtain the IP address: 1. Manually assigned. 2. DHCP serve r assigned. Y ou can select which way you prefer to o btain the IP by setting the IP S t ate mode. If Manual is select ed, the administrator must ...

  • ArtDio IPE 1000 - page 61

    61 Category Entry Description Dat a Ty p e Range IP S t ate Defines the mode used to acqui re an IP addre s s: Manual : static add re ss mode. The system admi nist r ator must assign the IP addre s s directly fro m the system console or web p age. Auto (DHCP) : If this mode is selected, the IP will be automatically obtained from the DHCP s erv er . ...

  • ArtDio IPE 1000 - page 62

    62 4.4 Channel Management Channel numbers and naming: There are up to 16 channel s that PBX gateway can suppo rt and the minimum port density is two. For la rge port number se ries, the port naming is given in 4 ports a gro up. For 7-inches se rie s, the port nam ing are given as its sequence. 19-inches and 12 inches models Sequence Name Sequence N ...

  • ArtDio IPE 1000 - page 63

    Category Entry Description Dat a Ty p e Range Channel The chan nel number . It displays Group/Port format. Port 2 in group 1 will be shown as 1/2 RO T wo groups and 4 port s for each group I/F T ype Shows the port interfac e type. RO FXS, FXO Operating Stat u s Shows the operation status of this port. Enable/Disable RO Enable Disable T .38 Whether ...

  • ArtDio IPE 1000 - page 64

    63 Console Commands PBX Gateway - PB X Gateway#sh ch annel group port m ode admin o peration vad T.38 input gain output gain ----- ---- - --- ------- - -------- ----- -- ---- ----- ----- ------ ----- 1 1 F XS enable enable enabl e No 0 0 1 2 F XS enable enable enabl e No 0 0 1 3 F XS enable enable enabl e No 0 0 1 4 F XS enable enable enabl e No 0 ...

  • ArtDio IPE 1000 - page 65

    64 4.4.2 Regional The configuration shown in this p age applies to each channel on the entire device. Category Entry Description Data Ty p e Range Information Hook Fl ash Ti m e Defines the time frame of a break that is to be treated as a Flash signal. RW 200ms 300ms 400ms 500 ms 600 ms 700 ms 800 ms 900 ms 1000 ms ...

  • ArtDio IPE 1000 - page 66

    65 Category Entry Description Data Ty p e Range Duration Defines how long the DTM F will be sent when the gateway receives a DTMF Play Out message from the Call Agent. RW 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 DTMF Play out Inter Digit Ti m e Defines the inter-digit time of the DTMF when the gateway receives a DTMF Play Out mes ...

  • ArtDio IPE 1000 - page 67

    66 Category Entry Console Mode Console Command Information Flash T ime Channel Flash < 200 – 1000 > Duration Not supported in the console DTMF Play out Inter Digit Ti m e Not supported in the console Frequency Busy T one Spec. Cadenc e There is no such function in the Command Line Interface ...

  • ArtDio IPE 1000 - page 68

    67 4.4.3 Channel Configuration The configuration shown in this we b page applies to a single cha nn el. Y ou must select a channel and configure it to your pa rticular specifications. Web Manage ment Category Entry Description Dat a Ty p e Range Channel Channel number . Displays in Group/Port format. Port 2 in group 1 will be shown as 1/2 RW One or ...

  • ArtDio IPE 1000 - page 69

    68 Category Entry Description Dat a Ty p e Range Operational S tate Displays the current operational state s. RO Enable, Disable Device Capacity The maximu m numbe r of channels that are pe rmitte d to be configured to support the T .38. RO 2 (Only two channels are allowed to support T .38) Current Quantity The num be r of channels that are current ...

  • ArtDio IPE 1000 - page 70

    69 Console Commands Category Entry Console Mode Console Command Information Admin S tate Channel channel < group/port > < enable | disable> Enable/Di sable Channel t38_fax < group/port > <enable | disable > Redundan cy at high data rate Configure->Fa x fax high_redun <0-2> (default=1) Redundan cy at low data rate Co ...

  • ArtDio IPE 1000 - page 71

    70 4.4.4 S tatistics This web page sho ws the configurat ion and statistical informatio n of each channel. Y ou only have to select a channel number a nd cli ck the refresh button. The gateway will then return a p age sho wing its current configuration and st atistical data. Web Manage ment ...

  • ArtDio IPE 1000 - page 72

    71 Category Entry Description Dat a Ty p e Range Channel The channel number . Sho wn in the Group/Port format. Port 2 in group 1 will be shown as 1/2 RW Two gr ou ps and 4 port s for each group. 1/1 Current Code c T ype Displays the current codec in use by the channel RO Packet T ime (msec) Displays the current packet time in use by the channel RO ...

  • ArtDio IPE 1000 - page 73

    72 4.4.5 Call S tatus This web pag e sho ws the activities that are curr ently being performed on each port. Users must refresh the screen manually to check the curre nt port activities . The formats that are displayed he re are exactly the same as the CDR that sho ws from CDR ports (s ee Chapter 10 The Call Det ail Record information) Web Manage m ...

  • ArtDio IPE 1000 - page 74

    73 4.5 Management Interfaces PBX V oIP Gateways are flexible with the W eb Mana gement Interface, Console Management Interfaces (through RS-232), T elnet and Phone Set Configuration Interfaces. Y ou can configure the pa ra meters for different man agement interfaces through the web management interface or through the manag ement interface itself. F ...

  • ArtDio IPE 1000 - page 75

    74 Category Entry Description Dat a Ty p e Range Password Threshold The session will be halted if the number of invalid password tries has reached the thresh old. Please note that it applies only to the console and T elnet, it does not apply to the web interface. The value of 0 stands fo r no p assword threshold. RW 0 – 255 (Default:1) Silent Ti ...

  • ArtDio IPE 1000 - page 76

    75 4.5.2 Console Commands Category Entry Console Mode Console Command Session Ti m e o u t Console time-out < 0-255 > in minutes Data bit s Console data bits <7/8> Password Threshold Console password-thresh < 0-255 > Silent Ti m e Console silent-time < 0-255 > in minutes Baud Rate Console speed <2400 | 9600 | 19200 | 3840 ...

  • ArtDio IPE 1000 - page 77

    76 4.6 Sof tware Upgrade The software upgrade can only be done through a TF TP server , therefore you must have a TFTP server running on the network and the new firmwa re mu st be saved on the server . Y ou can issue a command to download it from the web management p age or syst em console. The followi ng steps are a guide to downloading the new fi ...

  • ArtDio IPE 1000 - page 78

    Category Entry Description Dat a Ty p e Range Firmware V ersion Displays the firmware version RO IP Address S pecifies the IP address of the TFTP se rver . A domain name is also allowed. RW IP address and domain name Download Path/File Name S pecifies the path of the filename in the TFTP server such as: C:/runtime.tcw RW S tring up to 48 charac ter ...

  • ArtDio IPE 1000 - page 79

    78 4.6.1 Console Commands Using the system co nsole to upgrade the firmware is q uite similar to using the We b management interface. Y ou must run the TFTP server first. Y ou must also assign the IP address of the TFTP server and filename separately . After they are configured, issue a copy co mmand to initiate the firmware upgrade. Y ou can also ...

  • ArtDio IPE 1000 - page 80

    79 Category Entry Console Mode Console Command IP Address Configuration tftp server < ip-address | domain name > Download Path/File Name Configuration tftp filename < filename > TFTP Serv er St a r t Downloadi ng Privileged T wo commands (If the TFTP server IP address and filenam e have already been assigned): copy tftp :/// Or specify ...

  • ArtDio IPE 1000 - page 81

    80 group_id Set s the grou p ID master_ip Sets the master's IP addre ss internal_ac Sets the internal access code for inter-gateway calls intn_code Sets the international access cod e for in-bound analysis local_pstn_ac Sets the local PSTN trunk acce ss code (if it exists) long_distance Sets the long dista nce access code for in-bound analy si ...

  • ArtDio IPE 1000 - page 82

    81 5. Phone Set Interface Configuration Procedures 5.1 Configuration procedures PROG Access Code Hook Off Password Item 2 Digits Dial Tone Confirmation Tone Data Confirmation Tone/Reject Tone Hook On Note 1 1 Use "#" as the en ding prompt for the data entry . Note 12 The (facto ry default) value PROG Access Code is "##" and the ...

  • ArtDio IPE 1000 - page 83

    82 5.2 Greeting Message Recording Procedure T o record the greeting message into the PBX gateway , the user must switch to the recording mode af ter entering the Phone Set Configurati on mode and pressing the ite m code “99”. If the user has already recorded a greeting messa ge, he or she can use the item code “96” to hear it. In the record ...

  • ArtDio IPE 1000 - page 84

    83 5.3 Configurable Items 5.3.1 Dat a Range Syntax for the dat a descriptions: In the Phone Set Programming Mode, all dat a entered is a combination of the 12 keys shown on the keypad on the phon e set panel. 123 456 789 *0 # x or 0|1|2|3|4|5|6|7|8|9 : Digit s that range from 0 to 9 '*' : Keypad "*" '#' : Keypad " ...

  • ArtDio IPE 1000 - page 85

    84 default value. 07 Coun try Code [1,3]f(0,9) 08 Area Code [1,3]f(0,9) 09 Prefix Code [1,4]f(0,9) 10 A dd an Inbound International Access Code [1,3]f(0,9) 1 1 Deletes an Inbound International Access Code [1,3]f(0,9) 12 Outbound International Access Code [1,3]f(0,9) 13 Long Dist ance Access Code (adds both In-bound and Out-bo und ) 20 [1,3]f(0,9) 1 ...

  • ArtDio IPE 1000 - page 86

    85 6. Firewall Configuration The PBX voice gateway uses UDP p ackets to transmit the call control signaling between devi ces, it also utilizes the normal RTP packet s to transmit the voice st reams. In order to allow communications to perform even thoughthe PBX gateway is install e d behind a firewall, the network admi nistrator m ust open the requ ...

  • ArtDio IPE 1000 - page 87

    86 On some firewall systems, you are not permitted to use we ll-known ports, in order to maintain security . In this case, users may need to change the default port numbers to allow the PBX gateway to function. Such modifications can be done through the W eb/Console Management Interfaces (refer to [System]->[Configuration] in Web o r [Ro uting] ...

  • ArtDio IPE 1000 - page 88

    87 7. Regulation Compliance Information 7.1 FCC FCC Class A This Equipment has been tested and found to comply with the limit s for a Class A di git al device, pursuant to Part 15 of FCC rules. The se limits are designed to provide reason able p rotection against harmful interference when the equipment is o pe rated in a commercial environment. Thi ...

  • ArtDio IPE 1000 - page 89

    88 8. Regional Tone adjustment For most countries, the tone specificatio ns a re not th e same. The di f ferences in p articular are with the definitions for Dial T one, Ring Back T one, Busy T one and Reorder T one. In order to make the PBX gateway capable of be ing installed in diff erent co untries, the device administrator can change the region ...

  • ArtDio IPE 1000 - page 90

    89 9. FTP for software upgrading, Configuration and Greeting Message uploading/downloading On the PBX Gateway series PBX gateway , it gives the user the option to upgrade the soft ware using FTP , which is less t ime consuming then TFTP . By using FTP , users ca n upgrade the soft ware on the PBX gateway or upload/download the g r eeting me ssa ge ...

  • ArtDio IPE 1000 - page 91

    90 10. The Call Detail Record information The CDR information is very useful for debugging the configuration settings and providi ng re cord s for billing systems. If users only want to chec k the routing or nu mberi ng plan configurations, they can use the Web-based Call S t atus screen in the Channel Managemen t. From the Web browser , users must ...

Производитель ArtDio Категория Network Card

Документы, которые мы получаем от производителя устройства ArtDio IPE 1000 мы можем разделить на несколько групп. Это в частности:
- технические чертежи ArtDio
- инструкции обслуживания IPE 1000
- паспорта изделия ArtDio
- информационные брошюры
- энергетические этикетки ArtDio IPE 1000
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания ArtDio IPE 1000.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа ArtDio IPE 1000, инструкции обслуживания, короткие инструкции или инструкции пользователя ArtDio IPE 1000. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия ArtDio IPE 1000.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства ArtDio IPE 1000, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании ArtDio IPE 1000 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей ArtDio IPE 1000.

Полная инструкция обслуживания ArtDio, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией ArtDio IPE 1000 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания ArtDio IPE 1000, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся ArtDio IPE 1000, которое найдем в данном документе
3. Советы по использованию основных функций устройства ArtDio IPE 1000 - которые должны облегчить нам первые шаги во время использования ArtDio IPE 1000
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем ArtDio IPE 1000
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра ArtDio IPE 1000 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся ArtDio IPE 1000?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с ArtDio IPE 1000, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с ArtDio IPE 1000 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)