    Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN - T AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y ...

  • Vermont Casting 1658 - page 2

    2 V er mont Castings Madison 30001453 Introduction Thank you for choosing a V ermont Castings Madison to meet your heating needs. We’re confident you will find the Madison to be an ef fective woodburning heater incorporating modern, non-catalytic combustion technology with the classic aesthetic appeal of its V ermont Castings lineage. The Madis ...

  • Vermont Casting 1658 - page 3

    3 V er mont Castings Madison 30001453 Specifications Madison, Model 1655 Series Range of Heat Output ............... 1 1,300 - 39,700 BTU’ s Maximum heat output .......................... 39,700 Btu’s/hr . 1 Area heated ...................................... Up to 1600 sq. ft. 2, EP A emissions ratings, g/h, non-catalytic ............... 3.3 3 ...

  • Vermont Casting 1658 - page 4

    4 V er mont Castings Madison 30001453 Chimneys Y our stove must be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney . Whichever of those types you use, the chimney and chimney connec- tor must be in good condition and kept clean. If ...

  • Vermont Casting 1658 - page 5

    5 V er mont Castings Madison 30001453 Masonry Chimneys, cont’d. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpa- per are a hazard and should be sealed with mortar or refractory cement. In the eve ...

  • Vermont Casting 1658 - page 6

    6 V er mont Castings Madison 30001453 Double-wall Chimney Connectors The Madison is approved for installation in the U.S. and Canada with double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory . Follow the instructions for assembling and installing double-wall co ...

  • Vermont Casting 1658 - page 7

    7 V er mont Castings Madison 30001453 Connection Above the Fireplace In this installation, the chimney connector enters the fireplace flue through a thimble located above the fireplace. (Fig. 6) The liner of the fireplace chimney should extend at least to the point at which the chimney connector enters the chimney . Follow all the guidelines fo ...

  • Vermont Casting 1658 - page 8

    8 V er mont Castings Madison 30001453 Floor Protection A tremendous amount of heat radiates from the bottom plate of your Madison. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox. Heat protection is provided through the use of a V er - ...

  • Vermont Casting 1658 - page 9

    9 V er mont Castings Madison 30001453 T o meet these requirements, a floor protector must be at least 54” (1372mm) wide (“A”,Fig. 12) and 52” (1320mm) deep (“B”, Fig. 12). Fireplace Hearth Protection Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not satisfy the “completely noncombu ...

  • Vermont Casting 1658 - page 10

    10 V er mont Castings Madison 30001453 W all Shields W all shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible mate- rial such as 1/2” (13mm) insulation board (Fig. 14) or common brick “laid on flat,” with the 3 ¹⁄₂ " (89mm) side down. Shields must be spaced out from the combustible sur- face ...

  • Vermont Casting 1658 - page 11

    1 1 V er mont Castings Madison 30001453 Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations. ALCOVE INST ALLA TION OF THE MADISON IS NO ...

  • Vermont Casting 1658 - page 12

    12 V er mont Castings Madison 30001453 Madison 1655 Series Clearance Chart Use the chart below together with the diagrams on the next page to determine the minimum clearance required for your particular installation. In any case, it is always advisable to locate the stove as far away from walls as possible in order to take full advantage of the rad ...

  • Vermont Casting 1658 - page 13

    13 V er mont Castings Madison 30001453 F F C C A B D E J K L L G H ST553 Madison Clearance Diagrams  11/00 P Q M N I I O O R R V W S T U U X X Stove Installed Parallel to W all Stove in Corner Stove Installed Parallel to W all Stove in Corner PROTECTED SURF ACES T op Exit Installations, no heat shields T op Exit Installations, heat shield ...

  • Vermont Casting 1658 - page 14

    14 V er mont Castings Madison 30001453 Stove Installed Parallel to W all Stove in Corner Stove Installed Parallel to W all Stove in Corner PROTECTED SURF ACES Madison 1655 Series Clearance Diagram UNPROTECTED SURF ACES Rear Exit Installations, Bottom Heat Shield, floor protec- tion, minimum 18” (457mm) in front. Y Z AA BB EE FF CC DD ST563 Ma ...

  • Vermont Casting 1658 - page 15

    15 V er mont Castings Madison 30001453 ST465 Se ville Install  bottom heat shield Y ou will need the following tools to assemble the Madi- son: • 9/16” open end wrench • safety glasses & gloves • fl at h ead scr ewd rive r • p ower dr ill w/ 1/8” (3m m) bit • stub handle phillips screwdriver Unpack the Stove 1. Remove th ...

  • Vermont Casting 1658 - page 16

    16 V er mont Castings Madison 30001453 Attach the Chimney Connector Insert the crimped end of the first section of chimney connector into the flue collar . Using the holes in the collar as guides, drill 1/8” (3mm) holes through the connector pipe. Use the three #10 x 1/2” sheet metal screws provided to secure the chimney connection to the fl ...

  • Vermont Casting 1658 - page 17

    17 V er mont Castings Madison 30001453 How the Madison Works Combustion control is achieved in the Madison through two separate air delivery systems. The primary air control lever , located at the left rear corner of the stove, controls the amount of incoming pri- mary air for starting, maintaining, and reviving the fire. More air entering the sto ...

  • Vermont Casting 1658 - page 18

    18 V er mont Castings Madison 30001453 ST263 star ting a fire 12/99 Fig. 27 Start a fire with small, dry kindling. ST263 ST264 good fire 12/99 Fig. 28 Gradually add larger pieces of wood until all the wood is burning well. ST264 In newer homes that are well-insulated and weather- tight, poor draft may result from insufficient air in t ...

  • Vermont Casting 1658 - page 19

    19 V er mont Castings Madison 30001453 NOTE: Some chimneys need to be “primed,” or warmed up, before they will draw sufficiently to sus- tain a fire. T o correct this situation, roll up a couple pieces of newspaper , place them on top of the kindling and toward the back of the stove, light them, and close the doors. This should heat the chimn ...

  • Vermont Casting 1658 - page 20

    20 V er mont Castings Madison 30001453 Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Madison looking new . The stove’s paint can be touched up as needed. First, clean the ...

  • Vermont Casting 1658 - page 21

    21 V er mont Castings Madison 30001453 The Chimney System Creosote Y our Madison is designed to reduce creosote buildup significantly . However , regular chimney inspection and maintenance must still be performed. For safety , good stove performance, and to protect your chimney and chimney connector , inspect your chimney and chimney connector on ...

  • Vermont Casting 1658 - page 22

    22 V er mont Castings Madison 30001453 Y our stove is only one part of a system that includes the chimney , the operator , the fuel and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the stove works well. Wood stove operation depends on natural (unforced) draft. Natura ...

  • Vermont Casting 1658 - page 23

    23 V er mont Castings Madison 30001453 There should be no more than eight feet of single-wall stove pipe between the stove and a chimney . Longer runs can cool the smoke enough to cause draft and creosote problems. Use double-wall stove pipe for longer runs. Single V enting Y our stove requires a dedicated flue. Do not connect the stove to a flue ...

  • Vermont Casting 1658 - page 24

    24 V er mont Castings Madison 30001453 45 44 39 37 36 32 28 27 23 15 4 1 35 8 6 2 12 26 42 30 31 20 19 1 1 22 3 13 9 21 40 29 17 38 14 7 5 18 10 33 1453 Madison 1655 parts 6/01 16 43 34 24 25 41 46 47 1453 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products ...

  • Vermont Casting 1658 - page 25

    25 V er mont Castings Madison 30001453 15 14 16 17 1 10 8 12 1 1 3 2 9 5 4 7 6 1453 Madison Door X view 7/01 18 Madison W oodburning Stove Model 1655, 1656, 1657, 1658, 1659 (continued) Item Description Part Number 29. W asher , 1/4 pl 7/8 o.d. 1202470 30. Pan Hd, PH 10-24 x 1” blk 1200907 31. Nut, Square, 1/4-20 Pln 1203329 32. Insert Door Handl ...

  • Vermont Casting 1658 - page 26

    26 V er mont Castings Madison 30001453 Shell Enamel Parts - Madison Model 1655 Part Name Classic Green Moonlight Sand Red Suede Brown T op 30000817 30001213 3001203 30001 193 30001 183 30002599 Left Side 30000797 3000121 1 30001201 30001 191 30001 181 30002597 Right Side 30000796 30001210 30001200 30001 190 30001 180 30002596 Flue Collar 7000969 23 ...

  • Vermont Casting 1658 - page 27

    27 V er mont Castings Madison 30001453 W arranty Limited 3 Y ear W arranty CFM Specialty Home Products warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly , handles, glass door panels, ce- ment, and gasketing ...

  • Vermont Casting 1658 - page 28

    © CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products ...

Производитель Vermont Casting Категория Stove

Документы, которые мы получаем от производителя устройства Vermont Casting 1658 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vermont Casting
- инструкции обслуживания 1658
- паспорта изделия Vermont Casting
- информационные брошюры
- энергетические этикетки Vermont Casting 1658
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vermont Casting 1658.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vermont Casting 1658, инструкции обслуживания, короткие инструкции или инструкции пользователя Vermont Casting 1658. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vermont Casting 1658.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vermont Casting 1658, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vermont Casting 1658 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vermont Casting 1658.

Полная инструкция обслуживания Vermont Casting, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vermont Casting 1658 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vermont Casting 1658, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vermont Casting 1658, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vermont Casting 1658 - которые должны облегчить нам первые шаги во время использования Vermont Casting 1658
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vermont Casting 1658
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vermont Casting 1658 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vermont Casting 1658?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vermont Casting 1658, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vermont Casting 1658 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)