  • National Instruments CFP-20XX - page 1

    FieldPoint TM cFP-20 xx Quick Start Guide What Y ou Need to Get Set Up • cFP-20 xx LabVIEW RT controller • Mounting hardware (DIN rail, panel- mount, or rack-mount accessory) • I/O module(s) • Connectivity accessories: connector blocks, cables • 11–30 V power supply • Accessories: Ethernet cable, screwdriver • PC running Windows • ...

  • National Instruments CFP-20XX - page 2

    2 cFP-20xx Quick Start Guide ni.com Mounting the Backplane on a DIN Rail A. Fasten the DIN rail clip(s) to the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the clip(s). B. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip. C. Press down firmly on the backplane to ...

  • National Instruments CFP-20XX - page 3

    Mounting the Backplane on a Panel A. Fasten the panel-mount plates to the back of the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the kit. B. Bolt or screw the panel-mount accessory to a panel. C. Connect the PE ground terminal on the cFP-BP- x to safety ground. N A TIO N A L IN S TR U M ...

  • National Instruments CFP-20XX - page 4

    Mounting the Backplane in a Standard 19-in. Rack A. Fasten the rack-mount bracket to the back of the cFP-BP- x using the captive screws on the bracket. B. Bolt the rack-mount accessory to a standard 19-in. rack. C. Connect the PE ground terminal on the cFP-BP- x to safety ground. C C A A U U T T I I O O N N Disconnect power before removing the back ...

  • National Instruments CFP-20XX - page 5

    I I n n s s t t a a l l l l t t h h e e c c F F P P - - 2 2 0 0 x x x x C C o o n n t t r r o o l l l l e e r r o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Make sure that no power is connected to the controller or the backplane. B. Make sure that the cFP-20 xx controller is right side up with the NI logo at the top, and align the cap ...

  • National Instruments CFP-20XX - page 6

    6 cFP-20xx Quick Start Guide ni.com I I n n s s t t a a l l l l I I / / O O M M o o d d u u l l e e s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Align the captive screws on the I/O module with the holes on the backplane. B. Press firmly to seat the I/O module on the backplane. C. Using a number 2 Phillips screwdriver with a shank ...

  • National Instruments CFP-20XX - page 7

    I I n n s s t t a a l l l l C C o o n n n n e e c c t t o o r r B B l l o o c c k k s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e In order to connect I/O modules to input signals or to external loads, you need to install a cFP-CB- x connector block or other connectivity accessory for each I/O module on the backplane. Use the connector ...

  • National Instruments CFP-20XX - page 8

    C C o o n n n n e e c c t t t t h h e e c c F F P P - - 2 2 0 0 x x x x t t o o Y Y o o u u r r N N e e t t w w o o r r k k Connect the cFP-20 xx controller to an Ethernet network using the RJ-45 Ethernet port on the controller . Use a standard Category 5 Ethernet cable to connect the cFP-20 xx to an Ethernet hub, or use an Ethernet crossover cable ...

  • National Instruments CFP-20XX - page 9

    C. Use a separate power supply for each module that needs external power . D. Refer to the operating instructions for the power requirements of each I/O module. If a module requires external power , connect a power supply to the V and C inputs on the connector block for that module. If you want to power field I/O devices from a connector block, sup ...

  • National Instruments CFP-20XX - page 10

    I I n n s s t t a a l l l l S S o o f f t t w w a a r r e e o o n n t t h h e e H H o o s s t t P P C C A. Install the software packages you plan to use, such as LabVIEW , LabVIEW RT , Lookout, Measurement Studio, or LabWindows/CVI, before you install the FieldPoint software. The FieldPoint software installation installs the LabVIEW VIs and example ...

  • National Instruments CFP-20XX - page 11

    11 cFP-20xx Quick Start Guide © National Instruments Corporation C. Click the + + sign next to I I A A S S e e r r v v e e r r w w i i t t h h O O P P C C in the left pane to expand the view . Right-click F F i i e e l l d d P P o o i i n n t t and select A A d d d d a a c c o o m m m m r r e e s s o o u u r r c c e e t t o o t t h h i i s s s s e ...

  • National Instruments CFP-20XX - page 12

    G. Enter values on the Network Settings tab of the System Configuration dialog box, shown in the figure at right. If your network does not have a gateway server or DNS server , you should set those parameters to 0.0.0.0. • I I P P A A d d d d r r e e s s s s —The unique, computer-readable address of a device on your network. An IP address is ty ...

  • National Instruments CFP-20XX - page 13

    I. Enter an IP address for the T ime Server on the Servers tab of the System Configuration dialog box, shown in the figure at right. The time server is a networked computer that runs the National Instruments T ime Service installed by FieldPoint Explorer . Enter the IP address of the PC you are using. When you finish configuring the controller , th ...

  • National Instruments CFP-20XX - page 14

    14 cFP-20xx Quick Start Guide ni.com F F i i n n d d i i n n g g a a n n d d C C o o n n f f i i g g u u r r i i n n g g D D e e v v i i c c e e s s a a n n d d C C h h a a n n n n e e l l s s After you have configured the cFP-20 xx in FieldPoint Explorer , follow these steps to configure Compact FieldPoint devices and channels. A. In the Comm Reso ...

  • National Instruments CFP-20XX - page 15

    C. T o configure the hardware settings of a particular I/O module, right-click the device name and select E E d d i i t t t t h h i i s s d d e e v v i i c c e e . The Device Configuration dialog box appears, as shown in the figure above. For output modules, you can choose settings for Watchdog Configuration. Refer to the user manual for informatio ...

  • National Instruments CFP-20XX - page 16

    16 cFP-20xx Quick Start Guide ni.com D. Click C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n to access the Channel Configuration dialog box, shown in the figure at right. Make your selections in this dialog box as follows: 1. Select the type of channel to show , then select the channel(s) that you want to change. T ...

  • National Instruments CFP-20XX - page 17

    17 cFP-20xx Quick Start Guide © National Instruments Corporation ...

  • National Instruments CFP-20XX - page 18

    18 cFP-20xx Quick Start Guide ni.com S S a a v v i i n n g g H H a a r r d d w w a a r r e e C C o o n n f f i i g g u u r r a a t t i i o o n n a a s s P P o o w w e e r r - - U U p p S S t t a a t t e e When you are satisfied with the hardware configuration of the FieldPoint system, you can save this configuration as the new power -up state for t ...

  • National Instruments CFP-20XX - page 19

    ni.com Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.com/ask and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: United States 512 683 ...

Производитель National Instruments Категория Cell Phone

Документы, которые мы получаем от производителя устройства National Instruments CFP-20XX мы можем разделить на несколько групп. Это в частности:
- технические чертежи National Instruments
- инструкции обслуживания CFP-20XX
- паспорта изделия National Instruments
- информационные брошюры
- энергетические этикетки National Instruments CFP-20XX
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания National Instruments CFP-20XX.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа National Instruments CFP-20XX, инструкции обслуживания, короткие инструкции или инструкции пользователя National Instruments CFP-20XX. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия National Instruments CFP-20XX.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства National Instruments CFP-20XX, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании National Instruments CFP-20XX пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей National Instruments CFP-20XX.

Полная инструкция обслуживания National Instruments, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией National Instruments CFP-20XX - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания National Instruments CFP-20XX, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся National Instruments CFP-20XX, которое найдем в данном документе
3. Советы по использованию основных функций устройства National Instruments CFP-20XX - которые должны облегчить нам первые шаги во время использования National Instruments CFP-20XX
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем National Instruments CFP-20XX
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра National Instruments CFP-20XX в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся National Instruments CFP-20XX?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с National Instruments CFP-20XX, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с National Instruments CFP-20XX со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)