Инструкция обслуживания Raypak 538 To 4224

18 страниц 1.06 mb
Скачать

Перейти на страницу of 18

Summary
  • Raypak 538 To 4224 - page 1

    Raypak Commer cial Swimming P ool Heaters P art 1: Safety warning P art 2: Models 538 to 4224 P art 3: W arranty ...

  • Raypak 538 To 4224 - page 2

    3 CONTENTS P art 1: For Y our Safety This Installation and Operating Instructions Manual is provided with the necessary information for the proper installation, operation and maintenance of your Raypak Heater . Please review and follow these procedures carefully . K eep this manual in a safe and accessible place for easy reference in the future. P ...

  • Raypak 538 To 4224 - page 3

    P ART 1 - FOR Y OUR S AFETY 4 K eep this manual in a saf e and accessible place f or easy ref er ence in the futur e. This Installation and Operating Instr uctions Manual is pr ovided with the necessary infor mation f or the proper installation, operation and maintenance of y our Raypak Heat er . Please r eview and follow these pr ocedur es careful ...

  • Raypak 538 To 4224 - page 4

    P ART 1 - FOR Y OUR SAFETY 5 Ceramic Firetile Refractory is used in Raypak Heaters Possible risks of irreversible ef fects Harmful by inhalation May be irritating to the skin, eyes and respiratory system. WHEN HANDLING • Minimise airborne dust. • Wear an appr oved mask or respirator . • Avoid any contact with the skin and eyes. • Wear suita ...

  • Raypak 538 To 4224 - page 5

    6 Raypak Commer cial Swimming P ool Heaters P art 2: Models 538 to 4224 ...

  • Raypak 538 To 4224 - page 6

    7 P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS Before commencing installation: 1. Read these instructions in full ! 2. Check that the heater you have been supplied is suitable for the type of installation and the gas available. The gas supply pressure must be between the minimum and maximum shown on the heater data plate. GENERAL These instr ...

  • Raypak 538 To 4224 - page 7

    P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS 8 Raypak recommends a minimum length of vertical flue of three (3) metres to ensure correct draft. OUTDOOR INST ALLA TIONS. An outdoor heater must not be installed inside any roofed structure or under eaves, roof overhangs, or pool decks. It should also be at least 1500 mm, in any direction from a ...

  • Raypak 538 To 4224 - page 8

    9 P ART 2 - SECTION I - INST ALLA TION INSTRU CTIONS PUMP SELECTION The filtration pump must be sized to provide an adequate water flow for the filtration system and the heater . In some cases however , this can cause a high back pressure which reduces the filtration capacity and in this case it would be more of on advantage to install an additiona ...

  • Raypak 538 To 4224 - page 9

    C OMMISSIONING W ARNING: COMMISSIONING MUST ONL Y BE UNDERT AKEN BY A PROPERL Y AUTHORISED AND IN SOME CASES APPROPRIA TEL Y LICENSED PERSON WHO IS F AMILIAR WITH SAFE COMMISSIONING PROCEDURES. THE COMMISSIONING MA Y REQUIRE INSPECTION BY THE GAS SUPPL Y AUTHORITY , CHECK IF THIS IS APPLICABLE. RECOMMENDED C OMMISSIONING PROCEDURE. 1. Check that al ...

  • Raypak 538 To 4224 - page 10

    TO TURN OFF THE HEA TER 1. T urn the heater ON/OFF power isolation switch to the "OFF" position. EMERGENC Y SHUT -DOWN 1. T urn "OFF" the power supply to the heater 2. T urn "OFF" the gas isolation valve fitted close to the heater or the main gas supply . AFTER ST ART -UP W ARNING Should overheating occur or the gas su ...

  • Raypak 538 To 4224 - page 11

    P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS 1. FLAME FAILURE RESET: This is a combination rest button and indicator lamp. It indicates, when illuminated, that the ignition system has shutdown on its safety control. 2. ALARM FAIL & MUTE BUTTON: This is an optional extra, which will illuminate when the heater has genera ...

  • Raypak 538 To 4224 - page 12

    13 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS RL1 MTR12 INSTRU CTIONS FOR USE OF LAE ELECTRONIC THERMOST A TS. Raypak uses the MTR12T1RES series thermostats which is programmed to operate in the heating mode. The only adjustments that should normally be required are:- Set point (set):- Which is the water temperature that ...

  • Raypak 538 To 4224 - page 13

    14 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS MODELS WHICH ARE C ONNECTED T O A MICROZONE SYS TEM If the heater(s) are operated by a Microzone system, there will be a rotar y type control knob fitted which should be aligned to the desired temperature. HIGH LIMIT SWITCH. ALL heaters are fitted with a manual reset high limit switch. This control ...

  • Raypak 538 To 4224 - page 14

    15 P ART2 - SECTION II - OPERA TING INSTRU CTIONS RECOMMENDED SERVICE PROCEDURES It is a Raypak requirement that all Raypak supplied equipment is serviced at least annually . In some installations, due to the appliance location and/or workload it may be necessary to perform a service ever y six months. RECOMMENDED SERVICE PROCEDURE FOR ANNU AL SERV ...

  • Raypak 538 To 4224 - page 15

    16 W ARNING! ...

  • Raypak 538 To 4224 - page 16

    17 P ART 4 - W ARRANTY RA YP AK WARRANTY FOR COMMERCIAL SWIMMING POOL HEA TERS. Raypak Australia Pty Ltd* will: a) repair or , if necessary , replace any Raypak pool heater; or b) replace any component (or , if necessary , arrange the installation of a new pool heater), which falls within the Warranty Periods specified below , in accordance with an ...

  • Raypak 538 To 4224 - page 17

    18 NO TES ...

  • Raypak 538 To 4224 - page 18

    RHEEM SERVICE 1 31 031 WWW .RHEEM.COM.A U Quality System Quality Endorsed Company Manufactured by Raypak A ustralia 7 Geddes St. Mulgrav e Vic 31 70 Ph. (03) 9535 3333 F ax (03) 9560 497 4 JAN 2003 P/NO 96209131 ...

Производитель Raypak Категория Swimming Pool Heater

Документы, которые мы получаем от производителя устройства Raypak 538 To 4224 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Raypak
- инструкции обслуживания 538 To 4224
- паспорта изделия Raypak
- информационные брошюры
- энергетические этикетки Raypak 538 To 4224
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Raypak 538 To 4224.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Raypak 538 To 4224, инструкции обслуживания, короткие инструкции или инструкции пользователя Raypak 538 To 4224. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Raypak 538 To 4224.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Raypak 538 To 4224, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Raypak 538 To 4224 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Raypak 538 To 4224.

Полная инструкция обслуживания Raypak, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Raypak 538 To 4224 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Raypak 538 To 4224, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Raypak 538 To 4224, которое найдем в данном документе
3. Советы по использованию основных функций устройства Raypak 538 To 4224 - которые должны облегчить нам первые шаги во время использования Raypak 538 To 4224
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Raypak 538 To 4224
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Raypak 538 To 4224 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Raypak 538 To 4224?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Raypak 538 To 4224, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Raypak 538 To 4224 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)