  • Raypak 538 To 4224 - page 1

    Raypak Commer cial Swimming P ool Heaters P art 1: Safety warning P art 2: Models 538 to 4224 P art 3: W arranty ...

  • Raypak 538 To 4224 - page 2

    3 CONTENTS P art 1: For Y our Safety This Installation and Operating Instructions Manual is provided with the necessary information for the proper installation, operation and maintenance of your Raypak Heater . Please review and follow these procedures carefully . K eep this manual in a safe and accessible place for easy reference in the future. P ...

  • Raypak 538 To 4224 - page 3

    P ART 1 - FOR Y OUR S AFETY 4 K eep this manual in a saf e and accessible place f or easy ref er ence in the futur e. This Installation and Operating Instr uctions Manual is pr ovided with the necessary infor mation f or the proper installation, operation and maintenance of y our Raypak Heat er . Please r eview and follow these pr ocedur es careful ...

  • Raypak 538 To 4224 - page 4

    P ART 1 - FOR Y OUR SAFETY 5 Ceramic Firetile Refractory is used in Raypak Heaters Possible risks of irreversible ef fects Harmful by inhalation May be irritating to the skin, eyes and respiratory system. WHEN HANDLING • Minimise airborne dust. • Wear an appr oved mask or respirator . • Avoid any contact with the skin and eyes. • Wear suita ...

  • Raypak 538 To 4224 - page 5

    6 Raypak Commer cial Swimming P ool Heaters P art 2: Models 538 to 4224 ...

  • Raypak 538 To 4224 - page 6

    7 P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS Before commencing installation: 1. Read these instructions in full ! 2. Check that the heater you have been supplied is suitable for the type of installation and the gas available. The gas supply pressure must be between the minimum and maximum shown on the heater data plate. GENERAL These instr ...

  • Raypak 538 To 4224 - page 7

    P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS 8 Raypak recommends a minimum length of vertical flue of three (3) metres to ensure correct draft. OUTDOOR INST ALLA TIONS. An outdoor heater must not be installed inside any roofed structure or under eaves, roof overhangs, or pool decks. It should also be at least 1500 mm, in any direction from a ...

  • Raypak 538 To 4224 - page 8

    9 P ART 2 - SECTION I - INST ALLA TION INSTRU CTIONS PUMP SELECTION The filtration pump must be sized to provide an adequate water flow for the filtration system and the heater . In some cases however , this can cause a high back pressure which reduces the filtration capacity and in this case it would be more of on advantage to install an additiona ...

  • Raypak 538 To 4224 - page 9

    C OMMISSIONING W ARNING: COMMISSIONING MUST ONL Y BE UNDERT AKEN BY A PROPERL Y AUTHORISED AND IN SOME CASES APPROPRIA TEL Y LICENSED PERSON WHO IS F AMILIAR WITH SAFE COMMISSIONING PROCEDURES. THE COMMISSIONING MA Y REQUIRE INSPECTION BY THE GAS SUPPL Y AUTHORITY , CHECK IF THIS IS APPLICABLE. RECOMMENDED C OMMISSIONING PROCEDURE. 1. Check that al ...

  • Raypak 538 To 4224 - page 10

    TO TURN OFF THE HEA TER 1. T urn the heater ON/OFF power isolation switch to the "OFF" position. EMERGENC Y SHUT -DOWN 1. T urn "OFF" the power supply to the heater 2. T urn "OFF" the gas isolation valve fitted close to the heater or the main gas supply . AFTER ST ART -UP W ARNING Should overheating occur or the gas su ...

  • Raypak 538 To 4224 - page 11

    P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS 1. FLAME FAILURE RESET: This is a combination rest button and indicator lamp. It indicates, when illuminated, that the ignition system has shutdown on its safety control. 2. ALARM FAIL & MUTE BUTTON: This is an optional extra, which will illuminate when the heater has genera ...

  • Raypak 538 To 4224 - page 12

    13 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS RL1 MTR12 INSTRU CTIONS FOR USE OF LAE ELECTRONIC THERMOST A TS. Raypak uses the MTR12T1RES series thermostats which is programmed to operate in the heating mode. The only adjustments that should normally be required are:- Set point (set):- Which is the water temperature that ...

  • Raypak 538 To 4224 - page 13

    14 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS MODELS WHICH ARE C ONNECTED T O A MICROZONE SYS TEM If the heater(s) are operated by a Microzone system, there will be a rotar y type control knob fitted which should be aligned to the desired temperature. HIGH LIMIT SWITCH. ALL heaters are fitted with a manual reset high limit switch. This control ...

  • Raypak 538 To 4224 - page 14

    15 P ART2 - SECTION II - OPERA TING INSTRU CTIONS RECOMMENDED SERVICE PROCEDURES It is a Raypak requirement that all Raypak supplied equipment is serviced at least annually . In some installations, due to the appliance location and/or workload it may be necessary to perform a service ever y six months. RECOMMENDED SERVICE PROCEDURE FOR ANNU AL SERV ...

  • Raypak 538 To 4224 - page 15

    16 W ARNING! ...

  • Raypak 538 To 4224 - page 16

    17 P ART 4 - W ARRANTY RA YP AK WARRANTY FOR COMMERCIAL SWIMMING POOL HEA TERS. Raypak Australia Pty Ltd* will: a) repair or , if necessary , replace any Raypak pool heater; or b) replace any component (or , if necessary , arrange the installation of a new pool heater), which falls within the Warranty Periods specified below , in accordance with an ...

  • Raypak 538 To 4224 - page 17

    18 NO TES ...

  • Raypak 538 To 4224 - page 18

    RHEEM SERVICE 1 31 031 WWW .RHEEM.COM.A U Quality System Quality Endorsed Company Manufactured by Raypak A ustralia 7 Geddes St. Mulgrav e Vic 31 70 Ph. (03) 9535 3333 F ax (03) 9560 497 4 JAN 2003 P/NO 96209131 ...

Produzent Raypak Kategorie Swimming Pool Heater

Dokumente, die wir vom Produzenten des Geräts Raypak 538 To 4224 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Raypak
- Bedienungsanleitungen 538 To 4224
- Produktkarten Raypak
- Informationsbroschüren
- oder Energieetiketten Raypak 538 To 4224
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Raypak 538 To 4224.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Raypak 538 To 4224, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Raypak 538 To 4224. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Raypak 538 To 4224 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Raypak 538 To 4224, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Raypak 538 To 4224 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Raypak 538 To 4224 verständlich ist.

Eine gänzliche Bedienungsanleitung von Raypak sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Raypak 538 To 4224 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Raypak 538 To 4224 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Raypak 538 To 4224, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Raypak 538 To 4224 - die uns die ersten Schritte während der Nutzung von Raypak 538 To 4224 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Raypak 538 To 4224 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Raypak 538 To 4224 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Raypak 538 To 4224?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Raypak 538 To 4224 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Raypak 538 To 4224 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)