  • Royal U19019 G20 - page 1

    81139 Issue 3 52<$/&+(/7(1+$0 USERS INSTRU CTIONS THIS CAT I 2H APPLIANCE IS FOR USE ON NATURA L GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCT IO NS TO THE USER ...

  • Royal U19019 G20 - page 2

    DESCRIPTION The Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from the successful Roy al Cozy fires LFE using much of the techno logy and components used in the manufact ure of this appliance. The fuel bed has a reali stic coal effect util izing ceramic ‘coals’ and coal bed that allows seconda ...

  • Royal U19019 G20 - page 3

    TECHNICA L DATA Heats I nput Rates: High Setting 5.42 kW 18,500 Btu/h (Gros s) Low Setting 2.34 kW 8,000 Btu/ h This fire will run for 5.4 hour s on one therm of g a s on hig h setti ng . LOCATION OF COM BU S TI BL E SHE LV ES ABOVE F IRE SIDE OF F IRE Min. Height of 150 mm deep she lf Min. Dimensi on fro m ou ter edg e of fire above hearth = 830m ...

  • Royal U19019 G20 - page 4

    DISMANTLING THE F IRE BED FOR CLEANING (see fig.3, 4 & 5) Allow the appl iance to cool for 1 hour before handling an y components. Remove the controls cover and unscrew the two wing screws securi ng the canopy in place as shown in (fig 3). L ift the canopy off the appliance and place to one side. Support the glass panel a nd remove the four win ...

  • Royal U19019 G20 - page 5

    COAL LAYING INSTRUCTION S Lay the four front coals diagonally with the stepped corner sit ting on the sim ulated coal front and the small corner notch at the rear. L a y a further row of fo ur coal s behind the fro nt r ow with stepped corners in the rear corners of the front row, the two centre coals having no t ches in the rear top corners. L a y ...

  • Royal U19019 G20 - page 6

    Note: Should any ‘coals’ or the coal bed become damaged, lost or broken, only the correct replacem en ts must be obtained and fit ted before the appl iance is used. E x tra ‘coals’ etc. must not be added to the coal bed. The coal bed must alway s be assemb led as detai led. This a ppliance is fitted with an Oxy /pilot the purpose of wh ich ...

  • Royal U19019 G20 - page 7

    REGI STRATI ON RECORD Purchaser’ s Name ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ and Address ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ Supplier’ s Name ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ and Address ______________ ____ ____ ...

  • Royal U19019 G20 - page 8

    81140 Issue 3 52<$/&+(/7(1+$0 INSTALLATION AND SERVICING INSTRUCTIONS THIS CAT I 2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

  • Royal U19019 G20 - page 9

    DESCRIPTION The Roy al Chelt enham g l ass fronted high efficiency liv e fuel effect inset gas fire has been developed from the successful Roy a l Cozy fires. The fuel bed has a realistic coal effect utilising ceramic ‘c oals’ and coal bed that allows secondary air to be entrained into the bed for clean combustion, the burner is an aerated twin ...

  • Royal U19019 G20 - page 10

    INSTALLATION REGULATIONS AND REQUIREMENTS I n the interests of both the Law and of Safety , this appliance must only be installed by a competent person in accordance with the current Gas S afety (Installation and Use) Regulations or t he rules in force and t he manufacturer’ s instructions. Note: Failure to install a g as appliance correctly coul ...

  • Royal U19019 G20 - page 11

    Page 4 Clearance to side (tim ber surrounds etc .) Minimum cl earance required to any combustible materia l to the side of the appliance must be 150mm. Clearance to shelves. Minimum clearances t o undersides of a 150mm deep combustible shelf from the hearth must be 830mm. Add 12.5mm to this clearance for every 25mm increase in depth of shelf. ...

  • Royal U19019 G20 - page 12

    Page 5 ...

  • Royal U19019 G20 - page 13

    INSTALLATION USING A 5" DIAMETER METAL F LUE BOX Page 6 Important: The Flue restrictor pl ate must be removed see F ig 10. When the metal flue box is to be built-in as a false chimney breast using timber stud work with plasterboard fa cing, the flue box should be enveloped with insulation material such as rockwool or similar to prevent a build ...

  • Royal U19019 G20 - page 14

    INSTALLATION OF THE APP LIANCE Check that th e chimney conform s to the required specificati ons as previously stated. Ex amine the condition and carry out any remedial work, if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that sati sfactory smoke clearance has been established. If all the smoke is ...

  • Royal U19019 G20 - page 15

    Page 7 a (ii) If the spacer frame is to be used, attach the fram e to the rear of the appliance using either the screws and captive nuts removed from the appliance or supplied in the fixing kit, see fig 8. Place the fire in the required position; mark around the perimeter of the spacer frame remove the appliance and the spacer frame from the applia ...

  • Royal U19019 G20 - page 16

    Page 8 ...

  • Royal U19019 G20 - page 17

    Page 9 ...

  • Royal U19019 G20 - page 18

    Page 10 ...

  • Royal U19019 G20 - page 19

    Page 11 ...

  • Royal U19019 G20 - page 20

    Page 12 ...

  • Royal U19019 G20 - page 21

    CHECKING OP ERATION OF F IRE Purge the air from the appliance by rotating the control to the ig nition position, push the control to allow the air in the pipework to be purged, push the piezo to ignite the Oxy /pilot. Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot flame has been established. Depr ...

  • Royal U19019 G20 - page 22

    Complete the registration section at the end of this booklet. Advise that any component part of this appliance be guaranteed ag ainst defective workmanship or faulty materials for a period of twelve months from the date of purchase. Any such part will be replaced free of charge on receipt of the purchaser’ s address at the cost of postage only , ...

  • Royal U19019 G20 - page 23

    Page 15 ...

  • Royal U19019 G20 - page 24

    SHORT PA RTS LIST For spares contact the manufacturer at the address overleaf. DESCRIPTI ON CROSSLEE No GC No Piezo Ig niter 40245 397 686 Control Knob 40232 170 014 Control Valve 42143 378 092 Oxy/Pilot B urner Assembly 42313 170 415 Main I njector 42168 378 090 Complete Coal & Fibre Pack 42203 REGI STRATI ON RECORD Purchaser’ s Name ……? ...

Производитель Royal Категория Fire Pit

Документы, которые мы получаем от производителя устройства Royal U19019 G20 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Royal
- инструкции обслуживания U19019 G20
- паспорта изделия Royal
- информационные брошюры
- энергетические этикетки Royal U19019 G20
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Royal U19019 G20.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Royal U19019 G20, инструкции обслуживания, короткие инструкции или инструкции пользователя Royal U19019 G20. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Royal U19019 G20.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Royal U19019 G20, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Royal U19019 G20 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Royal U19019 G20.

Полная инструкция обслуживания Royal, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Royal U19019 G20 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Royal U19019 G20, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Royal U19019 G20, которое найдем в данном документе
3. Советы по использованию основных функций устройства Royal U19019 G20 - которые должны облегчить нам первые шаги во время использования Royal U19019 G20
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Royal U19019 G20
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Royal U19019 G20 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Royal U19019 G20?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Royal U19019 G20, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Royal U19019 G20 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)