    INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10002734 6/00 Rev. 0 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: * Do not try to light any appliance. * Do not touch any electric switch * Do not use any phone in your build ...

  • Vermont Casting A232 - page 2

    - 2 - T ABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ............................. ...

  • Vermont Casting A232 - page 3

    - 3 - This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CAN / CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. FOR SAFE INSTALLATION AND OPERATION ...

  • Vermont Casting A232 - page 4

    - 4 - A B C D E F G H J I K FIREPLACE DIMENSIONS MODEL A232 A 25" 635mm B 24 1/8" 613mm C 16" 406mm D 20" 508mm E 19" 483mm F 21" 533mm G 31 3/4" 806mm H 17 3/4" 451mm I 29 5/8" 752mm J 9" 229mm K5 1/4" 133mm L– – M– – N– – MODEL A232 ...

  • Vermont Casting A232 - page 5

    - 5 - GAS INLET & MANIFOLD PRESSURES Input Minimum Input Maximum Manifold Pressure NATURAL LP (Propane) 11" wc 13" wc 10" wc 4.5" wc 7" wc 3.5" wc 1/2" GAS SUPPLY 1/2" X 3/8" REDUCER 3/8" NIPPLE 3/8" NIPPLE 3/8" NIPPLE 3/8" X 3/8" SHUT OFF VALVE 3/8" UNION DO NOT USE THI ...

  • Vermont Casting A232 - page 6

    - 6 - INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right or left side of the A232 Gas Fireplace. 1. Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace. 2. Position switch assembly onto the back of the fireplace, then fasten two screws as shown ...

  • Vermont Casting A232 - page 7

    - 7 - Fig. 14 STRAIGHT B VENT CHIMNEY COMMON FLUE INSTALLATIONS In some areas it is possible to vent more than one gas fireplace into the same flue. You must ensure that the flue being shared has the proper capacity to handle both fireplaces. Check installation codes for venting capacity information. As always it is best to check with the authority ...

  • Vermont Casting A232 - page 8

    - 8 - Check Draft Here Fig. 16 Retrofitting To An Existing Brick Chimney It is strongly recommends installing an approved chimney liner in an existing brick chimney. This will maximize the potential draft of the chimney and lessen the effects of slow chimney start up. This is important because many homes (including older renovated ones) have become ...

  • Vermont Casting A232 - page 9

    - 9 - GENERAL GLASS INFORMATION Only glass approved for use in these products may be used for replacement. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. Under no circumstances should this fireplace be operated without the front glass or with a broken glass. Replacement of the ...

  • Vermont Casting A232 - page 10

    - 10 - KR2 KR5 KR6 KR4 KR3 KR1 Burner Lava Rock Placement GLASS CLEANING It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the gl ...

  • Vermont Casting A232 - page 11

    - 11 - Fig. 20a FLAME ADJUSTMENT (RN/RP MODELS) For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 20a & b) L O H I Turn counterclockwise to increase flame height. Turn clockwise to lower flame height. L O H I Turn counterclockwise to dec ...

  • Vermont Casting A232 - page 12

    - 12 - 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the ...

  • Vermont Casting A232 - page 13

    - 13 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOV A 820 MILLIVOL T V AL VE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. De ...

  • Vermont Casting A232 - page 14

    - 14 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED. • ALL WIRING CONNECTIONS • REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES • THERMOPILE NEEDS A MINIMUM 325mV. AD ...

  • Vermont Casting A232 - page 15

    - 15 - REPLACEMENT P ARTS LIST D ESCRIPTION A232 1. Log Set Complete 10000160 1a. Log Ember Front KR1 1b. Log Front Left KR2 1c. Log Front Right KR3 1d. Log Rear KR4 1e. Log Top Left KR5 1f. Log Top Right KR6 2. Burner Lava Rock (Package) 57897 3a. Burner with Tiles Nat. 10000198 3b. Burner with Tiles Prop. 57904 4. Ceramic Tile (single) 57803 5a. ...

  • Vermont Casting A232 - page 16

    - 16 - 29 30 27 5/6a/b 19 18 13 11 17 15 28 7a/b 21a,b 44 41 42 43 31 32 36 a/b 37 39 46 45 39 43 41 42 it HI LO O F F P IL O T 25a/b 48 47 40 40 14 33 42 43 33 49 26 #1 - COMPLETE LOG SET -- A232 1b 1d 1e 1f 1a 1c 22 23 3a/b 4 2 40 8 a/b 12 17 16 L O H I PILOT ADJ PILOT ON OFF 24 a/b 20 10 a/b 9 a/b REPLACEMENT P AR TS ...

  • Vermont Casting A232 - page 17

    - 17 - OPTIONS MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock IMT - Wall Mounted Thermostat REMOTE CONTROL For units with RN/RP valves ...

  • Vermont Casting A232 - page 18

    - 18 - 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www .vermontcastings.com CFM Majestic, Inc. © Copyright CFM Majestic, Inc. 10002734 6/00 BASIC W ARRANTY : The CFM Majestic, Inc.™ (hereinafter referred to collectively as the "Company") warrants that your new V ermont Castings Gas Appliance is free from ...

Производитель Vermont Casting Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Vermont Casting A232 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vermont Casting
- инструкции обслуживания A232
- паспорта изделия Vermont Casting
- информационные брошюры
- энергетические этикетки Vermont Casting A232
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vermont Casting A232.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vermont Casting A232, инструкции обслуживания, короткие инструкции или инструкции пользователя Vermont Casting A232. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vermont Casting A232.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vermont Casting A232, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vermont Casting A232 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vermont Casting A232.

Полная инструкция обслуживания Vermont Casting, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vermont Casting A232 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vermont Casting A232, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vermont Casting A232, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vermont Casting A232 - которые должны облегчить нам первые шаги во время использования Vermont Casting A232
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vermont Casting A232
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vermont Casting A232 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vermont Casting A232?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vermont Casting A232, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vermont Casting A232 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки