  • ResMed H4i - page 1

    English H4i™ HEATED H UMIDIFI ER User Guide English Patents and designs pending. HumidAire, H4i, ResControl, ResLink, R esT raxx, VP AP , VP AP A uto, A utoSet and SmartStart are trademarks of ResMed Ltd. HumidAire, AutoSet, SmartStart and VP AP are registered in U.S. P atent and T rade mark Of fice. © 2008 ResMed Ltd. 268183 -Eng /1 08 03 ResMe ...

  • ResMed H4i - page 2

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S et ting up your H4i for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed H4i - page 3

    1 Introduction English Introduction The H4i ™ is designed to moi sten the air delivered to your airway during Positi ve Airway Pressure (PAP) therapy. Indications for use The H4i is indicated for humidification of the air del ivered from a ResMed compatible CPAP therapy device. The H4i is for use only as recommende d by a physician. Contraindicat ...

  • ResMed H4i - page 4

    2 System Setup 1 Align your H4i wi th your flow gene rator and push them together until the y click into place. 2 Connect the power cord to the socket on th e rear of your flow generator. 3 Plug the other end of the power cord into the power outlet. Place the combined unit on a firm, level surface near your bed at a level lower than your sleeping p ...

  • ResMed H4i - page 5

    3 Setting up your H4i for use English Filling the Water Chamber 1 Open the cover. 2 Remove the water chamber. 3 Fill with fresh, clean water up the maximum water level mark. 4 Return the water chamber to the docking station. 5 Close the cover ensuring that it clicks into place. ! WARNING Do not overfill the water chamber as water may ent er the flo ...

  • ResMed H4i - page 6

    4 Starting and Stopping Treatment Warming your H4i The Warm-Up feature (not available on all Re sMed PAP d evices) is used to pre-hea t the water before starting treatm ent. Skip this step if you want to start immediately. To start the Warm-Up feature: 1 Select wa rmup by pressing on the control panel. 2 The WARMING scre en will appear to indica te ...

  • ResMed H4i - page 7

    5 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out cl eaning and maintenance of the water cha mber, cover and cover seal as described in thi s section. ! WARNING • Bewa re of electrocu tion. Do not immerse your flow ge nerator , doc king station or p ower cord in w ater . Always unp lug the devi ce before c ...

  • ResMed H4i - page 8

    6 Weekly Inspect the water chamber for wear and det erioration. Replace the water chamber if any component has cracked, become cloudy or pitted. Repla ce immediately if there is any leaking from the water chamber. White powder or deposits in the water chamber can be cleaned using a solution of one part vinegar to 10 parts water, as follows: 1 Fill ...

  • ResMed H4i - page 9

    7 Cleaning and Maintenance English Reassembling the H4i Reassemble the parts when they are clean and dry. 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted pr operly. 2 Put one cover arm into its pivot point on the docking station and ge ntly flex the other arm into its correspondin g point. The cove ...

  • ResMed H4i - page 10

    8 Troubleshooting If there is a problem, try the following sugg estions. If the problem cannot be so lved, contact your equipment suppl ier or ResMed. Do not open the unit. ! WARNING Service and repair sho uld only be performed by an authorized service age nt. Pro b le m Possible Cause Solu tio n Device not w orking (no displa y on LCD screen and/o ...

  • ResMed H4i - page 11

    9 T echnical Specifications English Technical Specifications Humidifier Performance The following settings have been tested at 22°C, 40% RH ambi ent conditions: Note: The manufactu rer reserves the right to change th ese specifications without notice. Symbols which appear on the device Attention, consult accompany ing documents; Type CF equipment; ...

  • ResMed H4i - page 12

    10 General Warnings A warning alerts you to possible injury. Specific warning s and cautions appear n ext to the relevant instructio ns in the manual. • Use the H4i only for its intended use as described in this manual. • Make sure that the water c hamber is empt y before transporting the H4i. • The H4i is designed only for use w ith spec ifi ...

  • ResMed H4i - page 13

    11 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period sp ecified below from the date of purc hase by the initial co nsumer. Th is wa rranty is not transf erable. Note: Some models are not available in all regi ons. If the product fails under condi ...

  • ResMed H4i - page 14

    12 ...

Produzent ResMed Kategorie Humidifier

Dokumente, die wir vom Produzenten des Geräts ResMed H4i erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen ResMed
- Bedienungsanleitungen H4i
- Produktkarten ResMed
- Informationsbroschüren
- oder Energieetiketten ResMed H4i
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung ResMed H4i.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen ResMed H4i, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen ResMed H4i. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts ResMed H4i ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts ResMed H4i, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von ResMed H4i hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von ResMed H4i verständlich ist.

Eine gänzliche Bedienungsanleitung von ResMed sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von ResMed H4i bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von ResMed H4i befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich ResMed H4i, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts ResMed H4i - die uns die ersten Schritte während der Nutzung von ResMed H4i erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit ResMed H4i hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von ResMed H4i im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich ResMed H4i?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit ResMed H4i nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit ResMed H4i hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)