Manual de instrucciones ResMed H4i

14 de páginas 0.37 mb
Descargar

Pasar a la página of 14

Summary
  • ResMed H4i - page 1

    English H4i™ HEATED H UMIDIFI ER User Guide English Patents and designs pending. HumidAire, H4i, ResControl, ResLink, R esT raxx, VP AP , VP AP A uto, A utoSet and SmartStart are trademarks of ResMed Ltd. HumidAire, AutoSet, SmartStart and VP AP are registered in U.S. P atent and T rade mark Of fice. © 2008 ResMed Ltd. 268183 -Eng /1 08 03 ResMe ...

  • ResMed H4i - page 2

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S et ting up your H4i for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed H4i - page 3

    1 Introduction English Introduction The H4i ™ is designed to moi sten the air delivered to your airway during Positi ve Airway Pressure (PAP) therapy. Indications for use The H4i is indicated for humidification of the air del ivered from a ResMed compatible CPAP therapy device. The H4i is for use only as recommende d by a physician. Contraindicat ...

  • ResMed H4i - page 4

    2 System Setup 1 Align your H4i wi th your flow gene rator and push them together until the y click into place. 2 Connect the power cord to the socket on th e rear of your flow generator. 3 Plug the other end of the power cord into the power outlet. Place the combined unit on a firm, level surface near your bed at a level lower than your sleeping p ...

  • ResMed H4i - page 5

    3 Setting up your H4i for use English Filling the Water Chamber 1 Open the cover. 2 Remove the water chamber. 3 Fill with fresh, clean water up the maximum water level mark. 4 Return the water chamber to the docking station. 5 Close the cover ensuring that it clicks into place. ! WARNING Do not overfill the water chamber as water may ent er the flo ...

  • ResMed H4i - page 6

    4 Starting and Stopping Treatment Warming your H4i The Warm-Up feature (not available on all Re sMed PAP d evices) is used to pre-hea t the water before starting treatm ent. Skip this step if you want to start immediately. To start the Warm-Up feature: 1 Select wa rmup by pressing on the control panel. 2 The WARMING scre en will appear to indica te ...

  • ResMed H4i - page 7

    5 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out cl eaning and maintenance of the water cha mber, cover and cover seal as described in thi s section. ! WARNING • Bewa re of electrocu tion. Do not immerse your flow ge nerator , doc king station or p ower cord in w ater . Always unp lug the devi ce before c ...

  • ResMed H4i - page 8

    6 Weekly Inspect the water chamber for wear and det erioration. Replace the water chamber if any component has cracked, become cloudy or pitted. Repla ce immediately if there is any leaking from the water chamber. White powder or deposits in the water chamber can be cleaned using a solution of one part vinegar to 10 parts water, as follows: 1 Fill ...

  • ResMed H4i - page 9

    7 Cleaning and Maintenance English Reassembling the H4i Reassemble the parts when they are clean and dry. 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted pr operly. 2 Put one cover arm into its pivot point on the docking station and ge ntly flex the other arm into its correspondin g point. The cove ...

  • ResMed H4i - page 10

    8 Troubleshooting If there is a problem, try the following sugg estions. If the problem cannot be so lved, contact your equipment suppl ier or ResMed. Do not open the unit. ! WARNING Service and repair sho uld only be performed by an authorized service age nt. Pro b le m Possible Cause Solu tio n Device not w orking (no displa y on LCD screen and/o ...

  • ResMed H4i - page 11

    9 T echnical Specifications English Technical Specifications Humidifier Performance The following settings have been tested at 22°C, 40% RH ambi ent conditions: Note: The manufactu rer reserves the right to change th ese specifications without notice. Symbols which appear on the device Attention, consult accompany ing documents; Type CF equipment; ...

  • ResMed H4i - page 12

    10 General Warnings A warning alerts you to possible injury. Specific warning s and cautions appear n ext to the relevant instructio ns in the manual. • Use the H4i only for its intended use as described in this manual. • Make sure that the water c hamber is empt y before transporting the H4i. • The H4i is designed only for use w ith spec ifi ...

  • ResMed H4i - page 13

    11 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period sp ecified below from the date of purc hase by the initial co nsumer. Th is wa rranty is not transf erable. Note: Some models are not available in all regi ons. If the product fails under condi ...

  • ResMed H4i - page 14

    12 ...

Fabricante ResMed Categoría Humidifier

Los documentos del dispositivo ResMed H4i que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ResMed
- manuales de instrucciones H4i
- hojas de producto ResMed
- folletos informativos
- o etiquetas energéticas ResMed H4i
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ResMed H4i.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ResMed H4i, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ResMed H4i. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ResMed H4i.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ResMed H4i, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ResMed H4i. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ResMed H4i.

El manual de instrucciones completo de ResMed debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ResMed H4i - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ResMed H4i, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ResMed H4i que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ResMed H4i - que deben facilitarnos los primeros pasos durante el uso de ResMed H4i
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ResMed H4i
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ResMed H4i en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ResMed H4i?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ResMed H4i, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ResMed H4i probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)