    NOTE: Read the entire instruction manual before performing any service or maintenance. This symbol → indicates a change since the last issue. These procedures are for size 44,000 through 154,000 Btuh input units. Index Page SAFETY CONSIDERATIONS ..................................................1-2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCED ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 2

    WARNING: The ability to properly perform mainte- nance on this equipment requires certain expertise, me- chanical skills, tools, and equipment. If you do not possess these, do not attempt to perform any maintenance on this equipment other than those procedures recom- mended in the User’s Manual. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN POSS ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 3

    1. Downflow/Horizontal Each furnace requires 2 filters which are installed in the return-air duct. (See Fig. 4 and 5.) To remove filters for cleaning or replacement, proceed as follows: a. Disconnect electrical power before removing blower access door. b. Remove screw from front of door and remove blower access door. c. Reach up behind top plate, t ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 4

    9. If a greasy residue is present on blower wheel, remove wheel from the blower housing and wash it with an appropriate degreaser. To remove wheel: a. Mark blower wheel location on shaft before disassembly to ensure proper reassembly. b. Loosen setscrew holding blower wheel on motor shaft. NOTE: Mark blower mounting arms, motor, and blower housing ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 5

    WARNING: Blower access door switch opens 115-v power to furnace control. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warn- ing could result in electrical shock, personal injury, or death. NOTE: If thermostat terminals are jumpered before blower ac- cess door ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 6

    (8.) Reinstall cell inlet plates and burner assembly. Care must be exercised to center burners in cell openings. 11. Clean flame sensor with fine steelwool. 12. Remove old sealant from center panel and collector box flange and apply new sealant to collector box flange and reinstall on center panel, making sure all 8 screws are secure. NOTE: A relea ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 7

    c. Remove control access door. d. BRIEFLY remove either wire from the main limit switch until LED goes out, then reconnect it. NOTE: If wire to main limit is disconnected longer than 4 sec, main blower starts, and retrieval request is ignored. 2. When above items have been completed, the following will occur: a. LED flashes a status code 4 times. R ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 8

    Fig. 11—Furnace Control A99255 HUMIDIFIER TERMINAL (24-V AC 0.5 AMP MAX) LED OPERA TION & DIAGNOSTIC LIGHT HARNESS CONNECT OR 24-V TRANSFORMER SEC-2 SP ARE-1 SP ARE-2 EAC-1 EAC-ELECTR ONIC AIR CLEANER TERMINALS (115-V AC 1.0 AMP MAX) EAC-2 115-V AC (L2) NEUTRAL CONNECTION 24-V THERMOST A T TERMINALS BLOWER SPEED SELECTION TERMINALS INDUCER MO ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 9

    → Fig. 12—Furnace Wiring Diagram A00304 PCB BLOWER OFF DELAY SELECTION CHART 90 SEC 135 SEC 180 SEC 225 SEC GVR H I/L O RELA Y SEC-1 SEC-2 PL1 3 2 1 6 5 4 9 87 LED TEST/TWIN BLOWER OFF DELAY G R Y W C HUM HSI R I DR BLWR BLOWER SPEED SELECT FU1 COOL HEA T L2 PL3 PL2 VAC 120 L1 PR1 1 2 1 2 3 PR2 24 VAC -3A FUSE SP A RE-2 SP ARE-1 EAC-1 EAC-2 C 1 ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 10

    Fig. 13—Service Label A96263 SERVICE 11 NO PREVIOUS CODE - Stored sta tus codes are er ased when power (115 V or 24V) to control is interrupted or 48 hours after ea ch fault is cl eared. 12 BLOWER ON AFTER POWER UP ( 115V or 24V) - Blower ru ns for 90 seconds, if unit is power ed up duri ng a call for hea t (R-W closed). 13 LI MIT OR FLAM E ROLL- ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 11

    —11— ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 12

    Is circuit breaker closed? Close door switch and go to start. Is red LED status light on? Is door switch closed? Is red LED status light blinking rapidly without a pause? Is there 1 15v going to switch? Replace door switch. Replace control center . Replace transformer . Is red LED status light blinking ON/OFF slowly with a combination of short and ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 13

    11 NO PREVIOUS F AUL T - Faults are erased after 48 hrs or whenever power (1 15v or 24v) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLO WER ON AFTER PO WER UP (115V OR 24V) - Normal operation. Blower will run for 90 sec when furnace power is interrupted during a call for heat, R-W closed. 13 LIMIT OR FLAME ROL ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 14

    —14— ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 15

    —15— ...

  • Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - page 16

    A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based f ...

Produzent Bryant Kategorie Furnace

Dokumente, die wir vom Produzenten des Geräts Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bryant
- Bedienungsanleitungen GAS-FIRED INDUCED-COUSTION FURNACES 373LAV
- Produktkarten Bryant
- Informationsbroschüren
- oder Energieetiketten Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV verständlich ist.

Eine gänzliche Bedienungsanleitung von Bryant sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV - die uns die ersten Schritte während der Nutzung von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bryant GAS-FIRED INDUCED-COUSTION FURNACES 373LAV hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)