Bedienungsanleitung Sea Frost 372 ROUTE

13 Seiten 0.7 mb
Download

Zur Seite of 13

Summary
  • Sea Frost 372 ROUTE - page 1

    1 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option CONDENSING UNIT LOCATION AND MOUNTING The water-cooling option should be consider ed supplemental cooling. Installation should proceed with a proper a ...

  • Sea Frost 372 ROUTE - page 2

    2 Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level, (the compressor is at the bottom). The BD may be platform mounted. Two holes have been drill ed through the bottom for screw ...

  • Sea Frost 372 ROUTE - page 3

    3 PUMP WIRING Connect the red pump wire to the terminal screw marked pump (+) and the black one to (-) under the compressor housing cover. Be sure the toggle switch is off until the boat is launched and the pump is wet. MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convecti ...

  • Sea Frost 372 ROUTE - page 4

    4 KINKING THE TUBES. ALL BENDS SH OULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with self- tapping screws. Insulate at least 3' of the line set as it exit s the refrigerator box. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound ...

  • Sea Frost 372 ROUTE - page 5

    5 WIRE SIZE 12-volt installations use AWG #10 wire for dist ances up to 10 feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. The remote water pump must be a 24volt pump. Fuse 7.5 Amps. If the polarity is ...

  • Sea Frost 372 ROUTE - page 6

    6 STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the ye llow wire harness, which is connected to terminals C and T on the module. The yellow wire harness contains a 1500-ohm resistor, which programs the module to oper ate the compressor at maximum RPM. There is no polarity requirement. STANDARD THERMOSTAT OPERATION The therm ...

  • Sea Frost 372 ROUTE - page 7

    7 OPTIONAL REMOTE THERMOSTAT OPERATION Attach the sensing bulb with the bulb clip to one of the lower mounting screws on the plate. The sensing bulb must be in excellent thermal contact with the plate. We re commend that the probe be mounted on the plate in one of the lower mounting positions as shown in the drawing below. This is best because thes ...

  • Sea Frost 372 ROUTE - page 8

    8 To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approx imately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turn ing the thermostat clockwise f ...

  • Sea Frost 372 ROUTE - page 9

    9 DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing t he evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD, the tubing in close proximity ...

  • Sea Frost 372 ROUTE - page 10

    10 TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual num ber of flashes there will be a delay ...

  • Sea Frost 372 ROUTE - page 11

    11 ...

  • Sea Frost 372 ROUTE - page 12

    12 AVAILABLE OPTIONS Remote Thermostat Panel Kit Speed Control Panel Kit Speed Control with Remote Thermostat Combination Panel Kit Electronic Thermostat Thermometer Panel Kit Remote Dial Thermometer 4" Vent Hose 4" Vent Grill Ice Tray Kit Bulkhead Mounting Brackets Bin Lid for Freezer Bin Water Cooling Option Water Pump ...

  • Sea Frost 372 ROUTE - page 13

    13 Our Repair Policy Your Sea Frost BD system is manufactured to t he highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the da ...

Produzent Sea Frost Kategorie Refrigerator

Dokumente, die wir vom Produzenten des Geräts Sea Frost 372 ROUTE erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sea Frost
- Bedienungsanleitungen 372 ROUTE
- Produktkarten Sea Frost
- Informationsbroschüren
- oder Energieetiketten Sea Frost 372 ROUTE
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sea Frost 372 ROUTE.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sea Frost 372 ROUTE, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sea Frost 372 ROUTE. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sea Frost 372 ROUTE ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Sea Frost 372 ROUTE, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sea Frost 372 ROUTE hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sea Frost 372 ROUTE verständlich ist.

Eine gänzliche Bedienungsanleitung von Sea Frost sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sea Frost 372 ROUTE bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sea Frost 372 ROUTE befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sea Frost 372 ROUTE, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sea Frost 372 ROUTE - die uns die ersten Schritte während der Nutzung von Sea Frost 372 ROUTE erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sea Frost 372 ROUTE hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sea Frost 372 ROUTE im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sea Frost 372 ROUTE?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sea Frost 372 ROUTE nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sea Frost 372 ROUTE hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)