Sea Frost 372 ROUTEの取扱説明書

13ページ 0.7 mb
ダウンロード

ページに移動 of 13

Summary
  • Sea Frost 372 ROUTE - page 1

    1 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option CONDENSING UNIT LOCATION AND MOUNTING The water-cooling option should be consider ed supplemental cooling. Installation should proceed with a proper a ...

  • Sea Frost 372 ROUTE - page 2

    2 Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level, (the compressor is at the bottom). The BD may be platform mounted. Two holes have been drill ed through the bottom for screw ...

  • Sea Frost 372 ROUTE - page 3

    3 PUMP WIRING Connect the red pump wire to the terminal screw marked pump (+) and the black one to (-) under the compressor housing cover. Be sure the toggle switch is off until the boat is launched and the pump is wet. MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convecti ...

  • Sea Frost 372 ROUTE - page 4

    4 KINKING THE TUBES. ALL BENDS SH OULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with self- tapping screws. Insulate at least 3' of the line set as it exit s the refrigerator box. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound ...

  • Sea Frost 372 ROUTE - page 5

    5 WIRE SIZE 12-volt installations use AWG #10 wire for dist ances up to 10 feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. The remote water pump must be a 24volt pump. Fuse 7.5 Amps. If the polarity is ...

  • Sea Frost 372 ROUTE - page 6

    6 STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the ye llow wire harness, which is connected to terminals C and T on the module. The yellow wire harness contains a 1500-ohm resistor, which programs the module to oper ate the compressor at maximum RPM. There is no polarity requirement. STANDARD THERMOSTAT OPERATION The therm ...

  • Sea Frost 372 ROUTE - page 7

    7 OPTIONAL REMOTE THERMOSTAT OPERATION Attach the sensing bulb with the bulb clip to one of the lower mounting screws on the plate. The sensing bulb must be in excellent thermal contact with the plate. We re commend that the probe be mounted on the plate in one of the lower mounting positions as shown in the drawing below. This is best because thes ...

  • Sea Frost 372 ROUTE - page 8

    8 To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approx imately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turn ing the thermostat clockwise f ...

  • Sea Frost 372 ROUTE - page 9

    9 DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing t he evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD, the tubing in close proximity ...

  • Sea Frost 372 ROUTE - page 10

    10 TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual num ber of flashes there will be a delay ...

  • Sea Frost 372 ROUTE - page 11

    11 ...

  • Sea Frost 372 ROUTE - page 12

    12 AVAILABLE OPTIONS Remote Thermostat Panel Kit Speed Control Panel Kit Speed Control with Remote Thermostat Combination Panel Kit Electronic Thermostat Thermometer Panel Kit Remote Dial Thermometer 4" Vent Hose 4" Vent Grill Ice Tray Kit Bulkhead Mounting Brackets Bin Lid for Freezer Bin Water Cooling Option Water Pump ...

  • Sea Frost 372 ROUTE - page 13

    13 Our Repair Policy Your Sea Frost BD system is manufactured to t he highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the da ...

メーカー Sea Frost カテゴリー Refrigerator

Sea Frost 372 ROUTEのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 372 ROUTEの取扱説明書
- Sea Frostの製品カード
- パンフレット
- またはSea Frost 372 ROUTEの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sea Frost 372 ROUTEの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sea Frost 372 ROUTEの取り付け説明書、サービスマニュアル、簡易説明書、またはSea Frost 372 ROUTEのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sea Frost 372 ROUTEの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sea Frost 372 ROUTEデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSea Frost 372 ROUTEを使用するのを助ける技術的文書のことです。説明書は通常、全てのSea Frost 372 ROUTEユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sea Frostの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sea Frost 372 ROUTEの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSea Frost 372 ROUTEの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sea Frost 372 ROUTEに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sea Frost 372 ROUTEデバイスの基本機能を使うにあたってのヒント。 Sea Frost 372 ROUTEのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sea Frost 372 ROUTEに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSea Frost 372 ROUTEのメーカー/サービスへの連絡先に関する情報。

Sea Frost 372 ROUTEについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSea Frost 372 ROUTEの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSea Frost 372 ROUTEで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)