Manuale per l’uso Sea Frost 372 ROUTE

13 pagine 0.7 mb
Scarica

Vai alla pagina of 13

Summary
  • Sea Frost 372 ROUTE - page 1

    1 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option CONDENSING UNIT LOCATION AND MOUNTING The water-cooling option should be consider ed supplemental cooling. Installation should proceed with a proper a ...

  • Sea Frost 372 ROUTE - page 2

    2 Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level, (the compressor is at the bottom). The BD may be platform mounted. Two holes have been drill ed through the bottom for screw ...

  • Sea Frost 372 ROUTE - page 3

    3 PUMP WIRING Connect the red pump wire to the terminal screw marked pump (+) and the black one to (-) under the compressor housing cover. Be sure the toggle switch is off until the boat is launched and the pump is wet. MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convecti ...

  • Sea Frost 372 ROUTE - page 4

    4 KINKING THE TUBES. ALL BENDS SH OULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with self- tapping screws. Insulate at least 3' of the line set as it exit s the refrigerator box. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound ...

  • Sea Frost 372 ROUTE - page 5

    5 WIRE SIZE 12-volt installations use AWG #10 wire for dist ances up to 10 feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. The remote water pump must be a 24volt pump. Fuse 7.5 Amps. If the polarity is ...

  • Sea Frost 372 ROUTE - page 6

    6 STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the ye llow wire harness, which is connected to terminals C and T on the module. The yellow wire harness contains a 1500-ohm resistor, which programs the module to oper ate the compressor at maximum RPM. There is no polarity requirement. STANDARD THERMOSTAT OPERATION The therm ...

  • Sea Frost 372 ROUTE - page 7

    7 OPTIONAL REMOTE THERMOSTAT OPERATION Attach the sensing bulb with the bulb clip to one of the lower mounting screws on the plate. The sensing bulb must be in excellent thermal contact with the plate. We re commend that the probe be mounted on the plate in one of the lower mounting positions as shown in the drawing below. This is best because thes ...

  • Sea Frost 372 ROUTE - page 8

    8 To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approx imately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turn ing the thermostat clockwise f ...

  • Sea Frost 372 ROUTE - page 9

    9 DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing t he evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD, the tubing in close proximity ...

  • Sea Frost 372 ROUTE - page 10

    10 TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual num ber of flashes there will be a delay ...

  • Sea Frost 372 ROUTE - page 11

    11 ...

  • Sea Frost 372 ROUTE - page 12

    12 AVAILABLE OPTIONS Remote Thermostat Panel Kit Speed Control Panel Kit Speed Control with Remote Thermostat Combination Panel Kit Electronic Thermostat Thermometer Panel Kit Remote Dial Thermometer 4" Vent Hose 4" Vent Grill Ice Tray Kit Bulkhead Mounting Brackets Bin Lid for Freezer Bin Water Cooling Option Water Pump ...

  • Sea Frost 372 ROUTE - page 13

    13 Our Repair Policy Your Sea Frost BD system is manufactured to t he highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the da ...

Fabbricante Sea Frost Categoria Refrigerator

I documenti che otteniamo dal fabbricante del dispositivoSea Frost 372 ROUTE possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Sea Frost
- manuali per l’uso 372 ROUTE
- schede prodotto Sea Frost
- opuscoli
- o etichette energetiche Sea Frost 372 ROUTE
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Sea Frost 372 ROUTE.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Sea Frost 372 ROUTE, manuali di manutenzione, brevi manuali o manuali utente Sea Frost 372 ROUTE. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Sea Frost 372 ROUTE.

Manuali per l’uso simili

Manuale completo del dispositivo Sea Frost 372 ROUTE, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Sea Frost 372 ROUTE dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Sea Frost 372 ROUTE.

Il manuale per l’uso completo Sea Frost, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Sea Frost 372 ROUTE - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Sea Frost 372 ROUTE, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Sea Frost 372 ROUTE che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Sea Frost 372 ROUTE - che ci dovrebbe aiutare nei primi passi durante l'uso Sea Frost 372 ROUTE
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Sea Frost 372 ROUTE
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Sea Frost 372 ROUTE in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Sea Frost 372 ROUTE?

Utilizza il modulo sottostante

Se non hai risolto il problema con Sea Frost 372 ROUTE con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Sea Frost 372 ROUTE è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)