    Model 8100 Energy Recovery V entilator Installation Instructions READ AND SA VE THESE INSTRUCTIONS CAUTION 1. Read all instructions before beginning installation. 2. The installation must conform to all applicable codes. 3. The fresh air duct from outside and to the house and the stale air duct from the unit to the outside must be fully insulated t ...

  • Aprilaire 8100 - page 2

    SPECIFICA TIONS Dimensions Unit – 37-7/16” W x 12-3/4” D x 20-9/16” H EnergyMax T ransfer Core – 12-1/8” x 12-1/8” x 10-3/4” Weight 75 lbs. Performance 77% Apparent Sensible Effectiveness (ASE) At rated ventilation capacity with 72°F indoor temperature and 32°F outdoor temperature. Capacity Maximum home size per ASHRAE Standard 62 ...

  • Aprilaire 8100 - page 3

    SERVICE CLEARANCE 12" 12" 36" 37-7/16" 20-9/16" CEILING MOUNTING HOLES CEILING MOUNTING HOLES ON / OFF SWITCH W ALL MOUNTING HOLES W ALL MOUNTING HOLES RETURN ST ALE AIR SUPP LY FRESH AIR EXTERNAL CONTROL WIRING ACCESS 6" ROUND COLLARS 12-3/4" 6" ROUND COLLARS 2" 2" FIGURE 3 – Dimensions and Locat ...

  • Aprilaire 8100 - page 4

    The unit can be mounted on a concrete wall or on a stud wall. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. stud spacing. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. 1. Remove the access panel, EnergyMax T ransfer Core and filters. (See Figure 4 .) 2. For Stud W all: ...

  • Aprilaire 8100 - page 5

    MECHANICAL INST ALLA TION (CONTINUED) CEILING MOUNT The unit can be mounted on ceiling joists. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. ceiling joists. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. CAUTION: Do not mount the ERV to ceiling I-beam wood trusses. 1. Re ...

  • Aprilaire 8100 - page 6

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING DUCT WORK SPECIFICATIONS •  Plan ontemporarily installing two airflow measuring devices. The systemwill have to be balanced( BALANCING THE SYSTEM SECTION ), after all duct work has been installed. The measuring devices are removed after the system ...

  • Aprilaire 8100 - page 7

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING (CONTINUED) RETURN: FROM LIVING SPACE TO ERV •  Stale airfrom the house should beexhausted from one exhaustgrille centrally located, such asa hallway .For multi-floor homes,the exhaust grille should be located on the same floor ...

  • Aprilaire 8100 - page 8

    MECHANICAL INST ALLA TION (CONTINUED) BALANCING THE SYSTEM DUCTING (CONTINUED) EQUIPMENT REQUIRED •  The intakeand exhaust hoods must belocated at least 10ft.  apart to avoid cross contamination. (See Figure 18 .) •  Intake andexhaust hoods should be abovethe exposed sno ...

  • Aprilaire 8100 - page 9

    5 FT . MIN. 5 FT . MIN. 2-1/2 FT 2-1/2 FT PRESSURE GAUGES ST ALE AIR FROM HOUSE FRESH AIR FROM OUTSIDE FRESH AIR TO HOUSE ST ALE AIR TO OUTSIDE AIR FLOW MEASURING DEVICE #5158 AIR FLOW MEASURING DEVICE #5158 DAMPER DAMPER FIGURE 19 – Set-up for Balancing Airflow 90-1746 BALANCING THE SYSTEM (CONTINUED) BALANCING AIRFLOW 1. Drill a 7/8” hole in ...

  • Aprilaire 8100 - page 10

    SYSTEM ST ART -UP CONSTANT ON OPERATION OPERATION WITH HOME COMFORT CONTROL ™ (FIGURE 20) OPERATION WITH 8120 VENTILATION CONTROLLER OR THIRD-PARTY CONTROL (FIGURE 20) The Energy Recovery V entilator has an on/off switch which enables the unit to be constantly on. There is also wiring access and wire leads available in the unit for connection to ...

  • Aprilaire 8100 - page 11

    SYSTEM ST ART -UP (CONTINUED) T able 2 – V entilation Air Requirements, CFM Home Size (ft 2 ) Number of Bedrooms < 2 2 - 3 4 - 5 6 - 7 > 7 ≤ 1500 30 45 60 75 90 1501 – 3000 45 60 75 90 105 3001 – 4500 60 75 90 105 120 4501 – 6000 75 90 105 120 135 6001 – 7500 90 105 120 135 150 > 7500 105 120 135 150 165 T able 3 – Cycle T im ...

  • Aprilaire 8100 - page 12

    P.O.Box1467•Madison,WI53701-1467•Phone:800/334-6011 •Fax:608/257-4357• www.aprilairepartners.com 10009736 1.12 B2701202A Printed in U.S.A. © 2012 Aprilaire – A division of Research Products Corporation TROUBLESHOOTING T echnical Support is available Monday through Friday , 7:00 a.m. to 5:00 p.m. CST ...

Produzent Aprilaire Kategorie Ventilation Hood

Dokumente, die wir vom Produzenten des Geräts Aprilaire 8100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Aprilaire
- Bedienungsanleitungen 8100
- Produktkarten Aprilaire
- Informationsbroschüren
- oder Energieetiketten Aprilaire 8100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Aprilaire 8100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Aprilaire 8100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Aprilaire 8100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Aprilaire 8100 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Aprilaire 8100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Aprilaire 8100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Aprilaire 8100 verständlich ist.

Eine gänzliche Bedienungsanleitung von Aprilaire sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Aprilaire 8100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Aprilaire 8100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Aprilaire 8100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Aprilaire 8100 - die uns die ersten Schritte während der Nutzung von Aprilaire 8100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Aprilaire 8100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Aprilaire 8100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Aprilaire 8100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Aprilaire 8100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Aprilaire 8100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)