    Model 8100 Energy Recovery V entilator Installation Instructions READ AND SA VE THESE INSTRUCTIONS CAUTION 1. Read all instructions before beginning installation. 2. The installation must conform to all applicable codes. 3. The fresh air duct from outside and to the house and the stale air duct from the unit to the outside must be fully insulated t ...

  • Aprilaire 8100 - page 2

    SPECIFICA TIONS Dimensions Unit – 37-7/16” W x 12-3/4” D x 20-9/16” H EnergyMax T ransfer Core – 12-1/8” x 12-1/8” x 10-3/4” Weight 75 lbs. Performance 77% Apparent Sensible Effectiveness (ASE) At rated ventilation capacity with 72°F indoor temperature and 32°F outdoor temperature. Capacity Maximum home size per ASHRAE Standard 62 ...

  • Aprilaire 8100 - page 3

    SERVICE CLEARANCE 12" 12" 36" 37-7/16" 20-9/16" CEILING MOUNTING HOLES CEILING MOUNTING HOLES ON / OFF SWITCH W ALL MOUNTING HOLES W ALL MOUNTING HOLES RETURN ST ALE AIR SUPP LY FRESH AIR EXTERNAL CONTROL WIRING ACCESS 6" ROUND COLLARS 12-3/4" 6" ROUND COLLARS 2" 2" FIGURE 3 – Dimensions and Locat ...

  • Aprilaire 8100 - page 4

    The unit can be mounted on a concrete wall or on a stud wall. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. stud spacing. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. 1. Remove the access panel, EnergyMax T ransfer Core and filters. (See Figure 4 .) 2. For Stud W all: ...

  • Aprilaire 8100 - page 5

    MECHANICAL INST ALLA TION (CONTINUED) CEILING MOUNT The unit can be mounted on ceiling joists. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. ceiling joists. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. CAUTION: Do not mount the ERV to ceiling I-beam wood trusses. 1. Re ...

  • Aprilaire 8100 - page 6

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING DUCT WORK SPECIFICATIONS •  Plan ontemporarily installing two airflow measuring devices. The systemwill have to be balanced( BALANCING THE SYSTEM SECTION ), after all duct work has been installed. The measuring devices are removed after the system ...

  • Aprilaire 8100 - page 7

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING (CONTINUED) RETURN: FROM LIVING SPACE TO ERV •  Stale airfrom the house should beexhausted from one exhaustgrille centrally located, such asa hallway .For multi-floor homes,the exhaust grille should be located on the same floor ...

  • Aprilaire 8100 - page 8

    MECHANICAL INST ALLA TION (CONTINUED) BALANCING THE SYSTEM DUCTING (CONTINUED) EQUIPMENT REQUIRED •  The intakeand exhaust hoods must belocated at least 10ft.  apart to avoid cross contamination. (See Figure 18 .) •  Intake andexhaust hoods should be abovethe exposed sno ...

  • Aprilaire 8100 - page 9

    5 FT . MIN. 5 FT . MIN. 2-1/2 FT 2-1/2 FT PRESSURE GAUGES ST ALE AIR FROM HOUSE FRESH AIR FROM OUTSIDE FRESH AIR TO HOUSE ST ALE AIR TO OUTSIDE AIR FLOW MEASURING DEVICE #5158 AIR FLOW MEASURING DEVICE #5158 DAMPER DAMPER FIGURE 19 – Set-up for Balancing Airflow 90-1746 BALANCING THE SYSTEM (CONTINUED) BALANCING AIRFLOW 1. Drill a 7/8” hole in ...

  • Aprilaire 8100 - page 10

    SYSTEM ST ART -UP CONSTANT ON OPERATION OPERATION WITH HOME COMFORT CONTROL ™ (FIGURE 20) OPERATION WITH 8120 VENTILATION CONTROLLER OR THIRD-PARTY CONTROL (FIGURE 20) The Energy Recovery V entilator has an on/off switch which enables the unit to be constantly on. There is also wiring access and wire leads available in the unit for connection to ...

  • Aprilaire 8100 - page 11

    SYSTEM ST ART -UP (CONTINUED) T able 2 – V entilation Air Requirements, CFM Home Size (ft 2 ) Number of Bedrooms < 2 2 - 3 4 - 5 6 - 7 > 7 ≤ 1500 30 45 60 75 90 1501 – 3000 45 60 75 90 105 3001 – 4500 60 75 90 105 120 4501 – 6000 75 90 105 120 135 6001 – 7500 90 105 120 135 150 > 7500 105 120 135 150 165 T able 3 – Cycle T im ...

  • Aprilaire 8100 - page 12

    P.O.Box1467•Madison,WI53701-1467•Phone:800/334-6011 •Fax:608/257-4357• www.aprilairepartners.com 10009736 1.12 B2701202A Printed in U.S.A. © 2012 Aprilaire – A division of Research Products Corporation TROUBLESHOOTING T echnical Support is available Monday through Friday , 7:00 a.m. to 5:00 p.m. CST ...

メーカー Aprilaire カテゴリー Ventilation Hood

Aprilaire 8100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 8100の取扱説明書
- Aprilaireの製品カード
- パンフレット
- またはAprilaire 8100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Aprilaire 8100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Aprilaire 8100の取り付け説明書、サービスマニュアル、簡易説明書、またはAprilaire 8100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Aprilaire 8100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Aprilaire 8100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAprilaire 8100を使用するのを助ける技術的文書のことです。説明書は通常、全てのAprilaire 8100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aprilaireの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Aprilaire 8100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAprilaire 8100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Aprilaire 8100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Aprilaire 8100デバイスの基本機能を使うにあたってのヒント。 Aprilaire 8100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Aprilaire 8100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAprilaire 8100のメーカー/サービスへの連絡先に関する情報。

Aprilaire 8100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAprilaire 8100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAprilaire 8100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)