  • Aprilaire 8100 - page 1

    Model 8100 Energy Recovery V entilator Installation Instructions READ AND SA VE THESE INSTRUCTIONS CAUTION 1. Read all instructions before beginning installation. 2. The installation must conform to all applicable codes. 3. The fresh air duct from outside and to the house and the stale air duct from the unit to the outside must be fully insulated t ...

  • Aprilaire 8100 - page 2

    SPECIFICA TIONS Dimensions Unit – 37-7/16” W x 12-3/4” D x 20-9/16” H EnergyMax T ransfer Core – 12-1/8” x 12-1/8” x 10-3/4” Weight 75 lbs. Performance 77% Apparent Sensible Effectiveness (ASE) At rated ventilation capacity with 72°F indoor temperature and 32°F outdoor temperature. Capacity Maximum home size per ASHRAE Standard 62 ...

  • Aprilaire 8100 - page 3

    SERVICE CLEARANCE 12" 12" 36" 37-7/16" 20-9/16" CEILING MOUNTING HOLES CEILING MOUNTING HOLES ON / OFF SWITCH W ALL MOUNTING HOLES W ALL MOUNTING HOLES RETURN ST ALE AIR SUPP LY FRESH AIR EXTERNAL CONTROL WIRING ACCESS 6" ROUND COLLARS 12-3/4" 6" ROUND COLLARS 2" 2" FIGURE 3 – Dimensions and Locat ...

  • Aprilaire 8100 - page 4

    The unit can be mounted on a concrete wall or on a stud wall. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. stud spacing. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. 1. Remove the access panel, EnergyMax T ransfer Core and filters. (See Figure 4 .) 2. For Stud W all: ...

  • Aprilaire 8100 - page 5

    MECHANICAL INST ALLA TION (CONTINUED) CEILING MOUNT The unit can be mounted on ceiling joists. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. ceiling joists. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. CAUTION: Do not mount the ERV to ceiling I-beam wood trusses. 1. Re ...

  • Aprilaire 8100 - page 6

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING DUCT WORK SPECIFICATIONS •  Plan ontemporarily installing two airflow measuring devices. The systemwill have to be balanced( BALANCING THE SYSTEM SECTION ), after all duct work has been installed. The measuring devices are removed after the system ...

  • Aprilaire 8100 - page 7

    MECHANICAL INST ALLA TION (CONTINUED) DUCTING (CONTINUED) RETURN: FROM LIVING SPACE TO ERV •  Stale airfrom the house should beexhausted from one exhaustgrille centrally located, such asa hallway .For multi-floor homes,the exhaust grille should be located on the same floor ...

  • Aprilaire 8100 - page 8

    MECHANICAL INST ALLA TION (CONTINUED) BALANCING THE SYSTEM DUCTING (CONTINUED) EQUIPMENT REQUIRED •  The intakeand exhaust hoods must belocated at least 10ft.  apart to avoid cross contamination. (See Figure 18 .) •  Intake andexhaust hoods should be abovethe exposed sno ...

  • Aprilaire 8100 - page 9

    5 FT . MIN. 5 FT . MIN. 2-1/2 FT 2-1/2 FT PRESSURE GAUGES ST ALE AIR FROM HOUSE FRESH AIR FROM OUTSIDE FRESH AIR TO HOUSE ST ALE AIR TO OUTSIDE AIR FLOW MEASURING DEVICE #5158 AIR FLOW MEASURING DEVICE #5158 DAMPER DAMPER FIGURE 19 – Set-up for Balancing Airflow 90-1746 BALANCING THE SYSTEM (CONTINUED) BALANCING AIRFLOW 1. Drill a 7/8” hole in ...

  • Aprilaire 8100 - page 10

    SYSTEM ST ART -UP CONSTANT ON OPERATION OPERATION WITH HOME COMFORT CONTROL ™ (FIGURE 20) OPERATION WITH 8120 VENTILATION CONTROLLER OR THIRD-PARTY CONTROL (FIGURE 20) The Energy Recovery V entilator has an on/off switch which enables the unit to be constantly on. There is also wiring access and wire leads available in the unit for connection to ...

  • Aprilaire 8100 - page 11

    SYSTEM ST ART -UP (CONTINUED) T able 2 – V entilation Air Requirements, CFM Home Size (ft 2 ) Number of Bedrooms < 2 2 - 3 4 - 5 6 - 7 > 7 ≤ 1500 30 45 60 75 90 1501 – 3000 45 60 75 90 105 3001 – 4500 60 75 90 105 120 4501 – 6000 75 90 105 120 135 6001 – 7500 90 105 120 135 150 > 7500 105 120 135 150 165 T able 3 – Cycle T im ...

  • Aprilaire 8100 - page 12

    P.O.Box1467•Madison,WI53701-1467•Phone:800/334-6011 •Fax:608/257-4357• www.aprilairepartners.com 10009736 1.12 B2701202A Printed in U.S.A. © 2012 Aprilaire – A division of Research Products Corporation TROUBLESHOOTING T echnical Support is available Monday through Friday , 7:00 a.m. to 5:00 p.m. CST ...

Manufacturer Aprilaire Category Ventilation Hood

Documents that we receive from a manufacturer of a Aprilaire 8100 can be divided into several groups. They are, among others:
- Aprilaire technical drawings
- 8100 manuals
- Aprilaire product data sheets
- information booklets
- or energy labels Aprilaire 8100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Aprilaire 8100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Aprilaire 8100, service manual, brief instructions and user manuals Aprilaire 8100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Aprilaire 8100.

Similar manuals

A complete manual for the device Aprilaire 8100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Aprilaire 8100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Aprilaire 8100.

A complete Aprilaire manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Aprilaire 8100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Aprilaire 8100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Aprilaire 8100, that we can find in the current document
3. Tips how to use the basic functions of the device Aprilaire 8100 - which should help us in our first steps of using Aprilaire 8100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Aprilaire 8100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Aprilaire 8100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Aprilaire 8100?

Use the form below

If you did not solve your problem by using a manual Aprilaire 8100, ask a question using the form below. If a user had a similar problem with Aprilaire 8100 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)