    200,000 Btu/Hr Model RM200T ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. POR T ABLE FORCED AIR HEA TER (WITH BUIL T -IN THERMOST A T) OWNER’S MANUAL ...

  • Desa RM200T - page 2

    2 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea ...

  • Desa RM200T - page 3

    3 103607 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . PRODUCT IDENTIFICA TION UNP ACKING Figure 1 - RM200T Model Lower Shell Hot Air Outlet Fan Guard Fuel Tank Flame-out Control ...

  • Desa RM200T - page 4

    4 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter an ...

  • Desa RM200T - page 5

    5 103607 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the ...

  • Desa RM200T - page 6

    6 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item Fuel tank Air output and lint filters Air intake filter Fuel filter Spark plug Fan blades Motor WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companie ...

  • Desa RM200T - page 7

    7 103607 OWNER’S MANUAL 1. Wrong pump pressure 2 . Dirty air output, air intake and lint filters 3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6. Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operati ...

  • Desa RM200T - page 8

    8 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater. The ...

  • Desa RM200T - page 9

    9 103607 OWNER’S MANUAL FUEL FILTER 1 . Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3 . Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel and replace in tank. 6. Attach lower fuel line to fuel valve f ...

  • Desa RM200T - page 10

    10 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR NOZZLE 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fan , page 8). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using ...

  • Desa RM200T - page 11

    11 103607 OWNER’S MANUAL Figure 16 - Removing Nozzle Figure 17 - Rotor Location Sandpaper Figure 19 - Sanding Rotor Figure 18 - Gap Adjusting Screw Locations Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Fitting Air Line Fitting SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell ...

  • Desa RM200T - page 12

    12 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 23 14 13 40 39 17 18 32 37 38 43 42 49 50 44 48 47 46 ILLUSTRA TED PA R T S BREAKDOWN RM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10-13 10- ...

  • Desa RM200T - page 13

    13 103607 OWNER’S MANUAL P AR TS LIST RM200T This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098511-229 ...

  • Desa RM200T - page 14

    14 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Btu/Hr 200,000 Flame-out Control Part No. HA3003 Spark Plug Part No. HA3012 Filter Kit Part No. HA3017 Nozzle Part No. 100735-13 Rotor/Air Pump Kit Part No. HA3005 Handle Part No. HA2204 Photocell Part No. HA3019 Pump Adjustment Part No. HA3020 1 2 3 4 WHEELS AND HANDLE PAR TS LIST KEY PART PAR ...

  • Desa RM200T - page 15

    15 103607 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts. This will protect your ...

  • Desa RM200T - page 16

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without cha ...

Produzent Desa Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts Desa RM200T erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Desa
- Bedienungsanleitungen RM200T
- Produktkarten Desa
- Informationsbroschüren
- oder Energieetiketten Desa RM200T
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Desa RM200T.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Desa RM200T, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Desa RM200T. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Desa RM200T ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Desa RM200T, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Desa RM200T hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Desa RM200T verständlich ist.

Eine gänzliche Bedienungsanleitung von Desa sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Desa RM200T bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Desa RM200T befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Desa RM200T, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Desa RM200T - die uns die ersten Schritte während der Nutzung von Desa RM200T erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Desa RM200T hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Desa RM200T im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Desa RM200T?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Desa RM200T nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Desa RM200T hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)