Manuale per l’uso Desa RM200T

16 pagine 0.35 mb
Scarica

Vai alla pagina of 16

Summary
  • Desa RM200T - page 1

    200,000 Btu/Hr Model RM200T ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. POR T ABLE FORCED AIR HEA TER (WITH BUIL T -IN THERMOST A T) OWNER’S MANUAL ...

  • Desa RM200T - page 2

    2 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea ...

  • Desa RM200T - page 3

    3 103607 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . PRODUCT IDENTIFICA TION UNP ACKING Figure 1 - RM200T Model Lower Shell Hot Air Outlet Fan Guard Fuel Tank Flame-out Control ...

  • Desa RM200T - page 4

    4 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter an ...

  • Desa RM200T - page 5

    5 103607 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the ...

  • Desa RM200T - page 6

    6 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item Fuel tank Air output and lint filters Air intake filter Fuel filter Spark plug Fan blades Motor WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companie ...

  • Desa RM200T - page 7

    7 103607 OWNER’S MANUAL 1. Wrong pump pressure 2 . Dirty air output, air intake and lint filters 3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6. Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operati ...

  • Desa RM200T - page 8

    8 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater. The ...

  • Desa RM200T - page 9

    9 103607 OWNER’S MANUAL FUEL FILTER 1 . Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3 . Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel and replace in tank. 6. Attach lower fuel line to fuel valve f ...

  • Desa RM200T - page 10

    10 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR NOZZLE 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fan , page 8). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using ...

  • Desa RM200T - page 11

    11 103607 OWNER’S MANUAL Figure 16 - Removing Nozzle Figure 17 - Rotor Location Sandpaper Figure 19 - Sanding Rotor Figure 18 - Gap Adjusting Screw Locations Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Fitting Air Line Fitting SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell ...

  • Desa RM200T - page 12

    12 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 23 14 13 40 39 17 18 32 37 38 43 42 49 50 44 48 47 46 ILLUSTRA TED PA R T S BREAKDOWN RM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10-13 10- ...

  • Desa RM200T - page 13

    13 103607 OWNER’S MANUAL P AR TS LIST RM200T This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098511-229 ...

  • Desa RM200T - page 14

    14 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Btu/Hr 200,000 Flame-out Control Part No. HA3003 Spark Plug Part No. HA3012 Filter Kit Part No. HA3017 Nozzle Part No. 100735-13 Rotor/Air Pump Kit Part No. HA3005 Handle Part No. HA2204 Photocell Part No. HA3019 Pump Adjustment Part No. HA3020 1 2 3 4 WHEELS AND HANDLE PAR TS LIST KEY PART PAR ...

  • Desa RM200T - page 15

    15 103607 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts. This will protect your ...

  • Desa RM200T - page 16

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without cha ...

Fabbricante Desa Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoDesa RM200T possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Desa
- manuali per l’uso RM200T
- schede prodotto Desa
- opuscoli
- o etichette energetiche Desa RM200T
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Desa RM200T.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Desa RM200T, manuali di manutenzione, brevi manuali o manuali utente Desa RM200T. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Desa RM200T.

Manuali per l’uso simili

Manuale completo del dispositivo Desa RM200T, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Desa RM200T dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Desa RM200T.

Il manuale per l’uso completo Desa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Desa RM200T - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Desa RM200T, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Desa RM200T che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Desa RM200T - che ci dovrebbe aiutare nei primi passi durante l'uso Desa RM200T
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Desa RM200T
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Desa RM200T in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Desa RM200T?

Utilizza il modulo sottostante

Se non hai risolto il problema con Desa RM200T con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Desa RM200T è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine