Инструкция обслуживания Desa RM200T

16 страниц 0.35 mb
Скачать

Перейти на страницу of 16

Summary
  • Desa RM200T - page 1

    200,000 Btu/Hr Model RM200T ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. POR T ABLE FORCED AIR HEA TER (WITH BUIL T -IN THERMOST A T) OWNER’S MANUAL ...

  • Desa RM200T - page 2

    2 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea ...

  • Desa RM200T - page 3

    3 103607 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . PRODUCT IDENTIFICA TION UNP ACKING Figure 1 - RM200T Model Lower Shell Hot Air Outlet Fan Guard Fuel Tank Flame-out Control ...

  • Desa RM200T - page 4

    4 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter an ...

  • Desa RM200T - page 5

    5 103607 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the ...

  • Desa RM200T - page 6

    6 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item Fuel tank Air output and lint filters Air intake filter Fuel filter Spark plug Fan blades Motor WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companie ...

  • Desa RM200T - page 7

    7 103607 OWNER’S MANUAL 1. Wrong pump pressure 2 . Dirty air output, air intake and lint filters 3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6. Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operati ...

  • Desa RM200T - page 8

    8 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater. The ...

  • Desa RM200T - page 9

    9 103607 OWNER’S MANUAL FUEL FILTER 1 . Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3 . Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel and replace in tank. 6. Attach lower fuel line to fuel valve f ...

  • Desa RM200T - page 10

    10 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR NOZZLE 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fan , page 8). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using ...

  • Desa RM200T - page 11

    11 103607 OWNER’S MANUAL Figure 16 - Removing Nozzle Figure 17 - Rotor Location Sandpaper Figure 19 - Sanding Rotor Figure 18 - Gap Adjusting Screw Locations Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Fitting Air Line Fitting SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell ...

  • Desa RM200T - page 12

    12 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 23 14 13 40 39 17 18 32 37 38 43 42 49 50 44 48 47 46 ILLUSTRA TED PA R T S BREAKDOWN RM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10-13 10- ...

  • Desa RM200T - page 13

    13 103607 OWNER’S MANUAL P AR TS LIST RM200T This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098511-229 ...

  • Desa RM200T - page 14

    14 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Btu/Hr 200,000 Flame-out Control Part No. HA3003 Spark Plug Part No. HA3012 Filter Kit Part No. HA3017 Nozzle Part No. 100735-13 Rotor/Air Pump Kit Part No. HA3005 Handle Part No. HA2204 Photocell Part No. HA3019 Pump Adjustment Part No. HA3020 1 2 3 4 WHEELS AND HANDLE PAR TS LIST KEY PART PAR ...

  • Desa RM200T - page 15

    15 103607 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts. This will protect your ...

  • Desa RM200T - page 16

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without cha ...

Производитель Desa Категория Thermostat

Документы, которые мы получаем от производителя устройства Desa RM200T мы можем разделить на несколько групп. Это в частности:
- технические чертежи Desa
- инструкции обслуживания RM200T
- паспорта изделия Desa
- информационные брошюры
- энергетические этикетки Desa RM200T
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Desa RM200T.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Desa RM200T, инструкции обслуживания, короткие инструкции или инструкции пользователя Desa RM200T. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Desa RM200T.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Desa RM200T, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Desa RM200T пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Desa RM200T.

Полная инструкция обслуживания Desa, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Desa RM200T - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Desa RM200T, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Desa RM200T, которое найдем в данном документе
3. Советы по использованию основных функций устройства Desa RM200T - которые должны облегчить нам первые шаги во время использования Desa RM200T
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Desa RM200T
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Desa RM200T в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Desa RM200T?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Desa RM200T, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Desa RM200T со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки