    CO 2 Meter Model IAQ10 OWNER’S MANUAL ...

  • Airflow Systems IAQ10 - page 2

    ii LIMITATION OF WA RRANTY A ND LIABILITY Seller warrants the goods sold hereunder, under normal use and ser vice as described in the operator's manual, s hall be free from defects in work manship and m aterial for twenty-four (24) months, or the length of tim e specif ied in the operator's manual, f rom the date of shipment to the c usto ...

  • Airflow Systems IAQ10 - page 3

    1 Table of Contents LIMITATION OF WARRANTY AN D LIABILITY ...... ii SECTION 1 General Descri ption ..................................... 2 SECTION 2 Theory of Opera tion: NDIR Sensor ........... 2 SECTION 3 Safety .............................................................. 3 SECTION 4 Setting-Up the Model IAQ10 ...................... 4 Supplying ...

  • Airflow Systems IAQ10 - page 4

    2 SECTION 1 General Description The Model IAQ10 is a hand-held meter to measure Carbon Dioxide (CO 2 ), displayed in units of parts per million (ppm). An NDIR sensor in the top end of the meter measures gas content by diffusion through sensing holes. The IAQ10 ships in a pouch that prov ides a small amount of protection to the display and the sensi ...

  • Airflow Systems IAQ10 - page 5

    3 concentrations. This technique is called non-dispersive infrared (NDIR) detection. SECTION 3 Safety When using the IAQ10 to check for CO 2 values, make certain that you can safely raise and hold the instrument while making measurements. Be especially careful when working on a ladder. Observe all necessary precautions so that the unit does not bec ...

  • Airflow Systems IAQ10 - page 6

    4 SECTION 4 Setting-Up the Model IAQ10 Supplying Power The IAQ10 can be powered in one of two ways: four AA-size batteries or the optiona l AC adapter. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Model IAQ10 is de- signed to operate only with alkaline batteries. ...

  • Airflow Systems IAQ10 - page 7

    5 SECTION 5 Operation of the Model IAQ10 Note : Do not hold the instrument close to your face. Humans exhale CO 2 and this will affect the accuracy of the readings. When pressing the keys on the keypad, the Model IAQ10 will beep to confirm the function. If you press a key and the Model IAQ10 does not beep, the Model IAQ10 does not allow that functi ...

  • Airflow Systems IAQ10 - page 8

    6 calibration. When the Model IAQ10 completes the internal self-check, it will display the approximate percentage of battery life remaining. Note : The sensor needs up to 10 minutes to stabilize in still air before displayed readings can be considered accurate. Moving the instrument may decrease this stabilization time. READ Key Carbon dioxide conc ...

  • Airflow Systems IAQ10 - page 9

    7 The display updates every second and each reading is the average of five samples. ( 5 ) Key The instrument only displays CO 2 . RECALL ( 6 ) Key Press the RECALL key repeatedly to display: minimum value ( MIN ), maximum value ( MAX ), average value ( AVG ), and number of seconds sampled ( COUNT ). Press the READ key to return to normal measuring ...

  • Airflow Systems IAQ10 - page 10

    8 SECTION 6 Maintenance of the Model IAQ10 The Model IAQ10 requires very little maintenance to keep it performing well. Case If the instrument case or storage case needs cleaning, wipe it off with a soft, damp cloth. Never submerge the IAQ10 in any liquid or allow any liquid to enter the sensing holes. Storage When storing the Model IAQ10 for more ...

  • Airflow Systems IAQ10 - page 11

    9 Before sending your instrument for calibration or repair, you should call Customer Service. The service department will provide you with the cost of service or calibration, Return Materia l Authorization (RMA) number, and shipping instructions. Please have the following information available when you call: • Owner’s name, address, and phone n ...

  • Airflow Systems IAQ10 - page 12

    10 you with a NIST (US Na tional Institute of Standards and Technology) traceable certificate. This “annual checkup” assures you of consistently accurate readings; it is especially important in applications where strict calibration records must be main- tained. Send the instrument to TSI Instruments Ltd. prepaid. Securely package your instrumen ...

  • Airflow Systems IAQ10 - page 13

    11 1. Turn the instrument off. Under the batteries, move DIP switch # 7 to ON. Turn the instrument back on. 2. Press and hold the READ key to begin the calibration procedure. The display will begin a countdown from 5 to 0. Release the key when the display reads 0. If the key is released too soon or too late, the instrument will go back to sam- plin ...

  • Airflow Systems IAQ10 - page 14

    12 indicates “ SPAN ” and the span concen- tration. 6. Install the regulator on the span calibra- tion cylinder and connect tubing from the regulator to the inlet fitting on the top of the Model IAQ10. 7. Use 5 and 6 to adjust the concentra- tion displayed on the Model IAQ10 to match the concentration on the span gas cylinder. 8. Press and rele ...

  • Airflow Systems IAQ10 - page 15

    13 SECTION 8 Troubleshooting of the Model IAQ10 This table lists the symptoms, possibl e causes, and recommended solutions for the Model IAQ10. Symptom Possible Causes Corrective A ction(s) No display Unit not switched on Switch on the unit Low or dead batteries Replace the batteries Dirty battery contacts Clean the battery contacts Batteries insta ...

  • Airflow Systems IAQ10 - page 16

    14 Symptom Possible Causes Corrective A ction(s) Display reads “LO” Batteries are low Replace the batteries Note: If your symptoms are not remedied by the suggested corrective action, call TSI Instruments Ltd. SECTION 9 Internal DIP Sw itch Settings To access the DIP switches, remove the batteries from the battery compartment. On the inside of ...

  • Airflow Systems IAQ10 - page 17

    15 DIP Sw itch OFF ON 1-3 Must be OFF ----- 4 not assigned not assigned 5 not assigned not assigned 6 Beep is turned OFF Beep is turned ON 7 Normal mode Field Verifica- tion mode 8 not assigned not assigned - The ON position is away from the batteries and OFF is towards the batteries. - Switch 1 is towards the top of the case and Switch 8 is neares ...

  • Airflow Systems IAQ10 - page 18

    ...

  • Airflow Systems IAQ10 - page 19

    Specifications (subject to change without n otice) CO 2 Sensor type: Dual wavelength detector with non - dispersive infrared (NDIR) sensor Range: 0 to 5000 ppm Accuracy ±3% of reading or ±50 ppm, which ever is greater 1, 2 Resolution 1 ppm Response time <10 minutes in still air Operating Temperat ure Range: 5 to 70°C External Meter Dimensions ...

  • Airflow Systems IAQ10 - page 20

    TSI Instruments Ltd. October 2005 Lancaster Road Printed in USA Cressex Business Park Part No. 1980532, Rev. A High Wycombe Buckinghamshire Tel: +44 (0) 149 4 459200 HP12 3QP England Fax: +44 (0) 149 4 459700 E-mail: info@airflowinstruments.co.uk Copyright © 2005 Web: www.a irf lo wins tr ume nts .c o. uk TSI Incorporated ...

Fabricante Airflow Systems Categoría Carbon Monoxide Alarm

Los documentos del dispositivo Airflow Systems IAQ10 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Airflow Systems
- manuales de instrucciones IAQ10
- hojas de producto Airflow Systems
- folletos informativos
- o etiquetas energéticas Airflow Systems IAQ10
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Airflow Systems IAQ10.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Airflow Systems IAQ10, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Airflow Systems IAQ10. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Airflow Systems IAQ10.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Airflow Systems IAQ10, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Airflow Systems IAQ10. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Airflow Systems IAQ10.

El manual de instrucciones completo de Airflow Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Airflow Systems IAQ10 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Airflow Systems IAQ10, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Airflow Systems IAQ10 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Airflow Systems IAQ10 - que deben facilitarnos los primeros pasos durante el uso de Airflow Systems IAQ10
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Airflow Systems IAQ10
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Airflow Systems IAQ10 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Airflow Systems IAQ10?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Airflow Systems IAQ10, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Airflow Systems IAQ10 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)