    CO 2 Meter Model IAQ10 OWNER’S MANUAL ...

  • Airflow Systems IAQ10 - page 2

    ii LIMITATION OF WA RRANTY A ND LIABILITY Seller warrants the goods sold hereunder, under normal use and ser vice as described in the operator's manual, s hall be free from defects in work manship and m aterial for twenty-four (24) months, or the length of tim e specif ied in the operator's manual, f rom the date of shipment to the c usto ...

  • Airflow Systems IAQ10 - page 3

    1 Table of Contents LIMITATION OF WARRANTY AN D LIABILITY ...... ii SECTION 1 General Descri ption ..................................... 2 SECTION 2 Theory of Opera tion: NDIR Sensor ........... 2 SECTION 3 Safety .............................................................. 3 SECTION 4 Setting-Up the Model IAQ10 ...................... 4 Supplying ...

  • Airflow Systems IAQ10 - page 4

    2 SECTION 1 General Description The Model IAQ10 is a hand-held meter to measure Carbon Dioxide (CO 2 ), displayed in units of parts per million (ppm). An NDIR sensor in the top end of the meter measures gas content by diffusion through sensing holes. The IAQ10 ships in a pouch that prov ides a small amount of protection to the display and the sensi ...

  • Airflow Systems IAQ10 - page 5

    3 concentrations. This technique is called non-dispersive infrared (NDIR) detection. SECTION 3 Safety When using the IAQ10 to check for CO 2 values, make certain that you can safely raise and hold the instrument while making measurements. Be especially careful when working on a ladder. Observe all necessary precautions so that the unit does not bec ...

  • Airflow Systems IAQ10 - page 6

    4 SECTION 4 Setting-Up the Model IAQ10 Supplying Power The IAQ10 can be powered in one of two ways: four AA-size batteries or the optiona l AC adapter. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Model IAQ10 is de- signed to operate only with alkaline batteries. ...

  • Airflow Systems IAQ10 - page 7

    5 SECTION 5 Operation of the Model IAQ10 Note : Do not hold the instrument close to your face. Humans exhale CO 2 and this will affect the accuracy of the readings. When pressing the keys on the keypad, the Model IAQ10 will beep to confirm the function. If you press a key and the Model IAQ10 does not beep, the Model IAQ10 does not allow that functi ...

  • Airflow Systems IAQ10 - page 8

    6 calibration. When the Model IAQ10 completes the internal self-check, it will display the approximate percentage of battery life remaining. Note : The sensor needs up to 10 minutes to stabilize in still air before displayed readings can be considered accurate. Moving the instrument may decrease this stabilization time. READ Key Carbon dioxide conc ...

  • Airflow Systems IAQ10 - page 9

    7 The display updates every second and each reading is the average of five samples. ( 5 ) Key The instrument only displays CO 2 . RECALL ( 6 ) Key Press the RECALL key repeatedly to display: minimum value ( MIN ), maximum value ( MAX ), average value ( AVG ), and number of seconds sampled ( COUNT ). Press the READ key to return to normal measuring ...

  • Airflow Systems IAQ10 - page 10

    8 SECTION 6 Maintenance of the Model IAQ10 The Model IAQ10 requires very little maintenance to keep it performing well. Case If the instrument case or storage case needs cleaning, wipe it off with a soft, damp cloth. Never submerge the IAQ10 in any liquid or allow any liquid to enter the sensing holes. Storage When storing the Model IAQ10 for more ...

  • Airflow Systems IAQ10 - page 11

    9 Before sending your instrument for calibration or repair, you should call Customer Service. The service department will provide you with the cost of service or calibration, Return Materia l Authorization (RMA) number, and shipping instructions. Please have the following information available when you call: • Owner’s name, address, and phone n ...

  • Airflow Systems IAQ10 - page 12

    10 you with a NIST (US Na tional Institute of Standards and Technology) traceable certificate. This “annual checkup” assures you of consistently accurate readings; it is especially important in applications where strict calibration records must be main- tained. Send the instrument to TSI Instruments Ltd. prepaid. Securely package your instrumen ...

  • Airflow Systems IAQ10 - page 13

    11 1. Turn the instrument off. Under the batteries, move DIP switch # 7 to ON. Turn the instrument back on. 2. Press and hold the READ key to begin the calibration procedure. The display will begin a countdown from 5 to 0. Release the key when the display reads 0. If the key is released too soon or too late, the instrument will go back to sam- plin ...

  • Airflow Systems IAQ10 - page 14

    12 indicates “ SPAN ” and the span concen- tration. 6. Install the regulator on the span calibra- tion cylinder and connect tubing from the regulator to the inlet fitting on the top of the Model IAQ10. 7. Use 5 and 6 to adjust the concentra- tion displayed on the Model IAQ10 to match the concentration on the span gas cylinder. 8. Press and rele ...

  • Airflow Systems IAQ10 - page 15

    13 SECTION 8 Troubleshooting of the Model IAQ10 This table lists the symptoms, possibl e causes, and recommended solutions for the Model IAQ10. Symptom Possible Causes Corrective A ction(s) No display Unit not switched on Switch on the unit Low or dead batteries Replace the batteries Dirty battery contacts Clean the battery contacts Batteries insta ...

  • Airflow Systems IAQ10 - page 16

    14 Symptom Possible Causes Corrective A ction(s) Display reads “LO” Batteries are low Replace the batteries Note: If your symptoms are not remedied by the suggested corrective action, call TSI Instruments Ltd. SECTION 9 Internal DIP Sw itch Settings To access the DIP switches, remove the batteries from the battery compartment. On the inside of ...

  • Airflow Systems IAQ10 - page 17

    15 DIP Sw itch OFF ON 1-3 Must be OFF ----- 4 not assigned not assigned 5 not assigned not assigned 6 Beep is turned OFF Beep is turned ON 7 Normal mode Field Verifica- tion mode 8 not assigned not assigned - The ON position is away from the batteries and OFF is towards the batteries. - Switch 1 is towards the top of the case and Switch 8 is neares ...

  • Airflow Systems IAQ10 - page 18

    ...

  • Airflow Systems IAQ10 - page 19

    Specifications (subject to change without n otice) CO 2 Sensor type: Dual wavelength detector with non - dispersive infrared (NDIR) sensor Range: 0 to 5000 ppm Accuracy ±3% of reading or ±50 ppm, which ever is greater 1, 2 Resolution 1 ppm Response time <10 minutes in still air Operating Temperat ure Range: 5 to 70°C External Meter Dimensions ...

  • Airflow Systems IAQ10 - page 20

    TSI Instruments Ltd. October 2005 Lancaster Road Printed in USA Cressex Business Park Part No. 1980532, Rev. A High Wycombe Buckinghamshire Tel: +44 (0) 149 4 459200 HP12 3QP England Fax: +44 (0) 149 4 459700 E-mail: info@airflowinstruments.co.uk Copyright © 2005 Web: www.a irf lo wins tr ume nts .c o. uk TSI Incorporated ...

Fabricant Airflow Systems Catégorie Carbon Monoxide Alarm

Les documents que nous recevons du fabricant de l'appareilAirflow Systems IAQ10 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Airflow Systems
- manuels d’utilisations IAQ10
- fiches produit Airflow Systems
- dépliants
- ou étiquettes-énergie Airflow Systems IAQ10
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Airflow Systems IAQ10.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Airflow Systems IAQ10, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Airflow Systems IAQ10. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Airflow Systems IAQ10.

Manuel d’utilisation complet de l’appareil Airflow Systems IAQ10, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Airflow Systems IAQ10 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Airflow Systems IAQ10.

Le manuel d’utilisation complet Airflow Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Airflow Systems IAQ10 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Airflow Systems IAQ10, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAirflow Systems IAQ10 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Airflow Systems IAQ10 - qui devraient nous aider dans les premières étapes lors de l'utilisation Airflow Systems IAQ10
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Airflow Systems IAQ10
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Airflow Systems IAQ10 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Airflow Systems IAQ10?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Airflow Systems IAQ10, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Airflow Systems IAQ10 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)