    Johnson Controls Unitary Produ cts 1031452-UIM-B-0513 R-22 OUTDOOR SPLIT -SYSTEM AIR CONDITIONING SHIPPED WITH NITROGEN CHARGE ONL Y MODELS: 13 SEER - GC GD 1.5 TO 5 T ONS INSTALLATION MANUAL ® LIST OF SECTIONS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY . . . . . . . . . . . . . . . ...

  • Johnson Controls 13 SEER - GCGD - page 2

    1031452-UIM-B-0513 2 Johnson Controls Unitary Products LIMIT A TIONS The unit should be installed in accordance with all National, S tate and Local Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessories must also be observed. 2. The outdoor unit must not be installed with any duct work i ...

  • Johnson Controls 13 SEER - GCGD - page 3

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 3 LIQUID LINE FIL TER-DRIER The air conditioning unit’s copper spun filter/dryer is located on the liq - uid line. PIPING CONNECTIONS The outdoor condensing unit must be connected to the indoor evapora - tor coil using field supplied r efrigerant grade (ACR) co pper tubing that is internally c ...

  • Johnson Controls 13 SEER - GCGD - page 4

    1031452-UIM-B-0513 4 Johnson Controls Unitary Products Connect the refrigerant lines u sing the following proced ure: 1. Remove the cap and Schrader core from both the liquid and vapor service valve service ports at the outdoor unit. Connect low pres- sure nitrogen to the liquid line service port. 2. Braze the liquid line to the liqui d valve at th ...

  • Johnson Controls 13 SEER - GCGD - page 5

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 5 SECTION V : TXV INST ALLA TIONS The following are the basic steps fo r inst allation. For detailed instruc- tions, refer to the Installation Instructions accompanying the TXV kit. Install TXV kit as follows: 1. Relieve the holding charge by pulling off the rubber cap plug on the suction manifo ...

  • Johnson Controls 13 SEER - GCGD - page 6

    1031452-UIM-B-0513 6 Johnson Controls Unitary Products SUPERHEA T CHARGING METHOD - PIST ON INDOOR 1. Operate system until temperatures and pressures stabilize (mini- mum of 10 minutes). 2. Measure and record indoor wet bulb (WB) temperature using a sling psychrometer and the outdoor dry bulb (DB) temperature using a thermometer . 3. Measure and re ...

  • Johnson Controls 13 SEER - GCGD - page 7

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 7 FIELD CONNECTIONS CONTR OL WIRING 1. Route low voltage wiring into bottom of control box as shown in Figure 6. Make low voltage wiring conne ctions inside the low volt- age box per Figures 7 - 1 1. 2. The complete connection diagram and schematic wiring label is located on the inside surface o ...

  • Johnson Controls 13 SEER - GCGD - page 8

    1031452-UIM-B-0513 8 Johnson Controls Unitary Products For additional connection diagrams for a ll UPG equipment refer to “Low V oltage System Wiring” document available online at www . upgnet.com in the Product Catalog Section. FIGURE 8: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1A Single Stage Air Conditioner – PSC Air Han ...

  • Johnson Controls 13 SEER - GCGD - page 9

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 9 FIGURE 9: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1B Single Stage Air Conditioner – PSC Air Handler C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER MA SHP AHP ID MODELS SINGLE STAGE AIR CONDIT I O N ER Other Part Nu mbers: SAP = Legacy 265902 = ...

  • Johnson Controls 13 SEER - GCGD - page 10

    1031452-UIM-B-0513 10 Johnson Controls Unitary Products FIGURE 10: Thermostat Chart - Single S tage AC with PSC Furnace AC 5A Single Stage Air Conditioner – Single Stage PSC Furnace G*9F G*(8/9)S F*(8/9) S PS(8/9) GF(8/9) G8C L*8S C 24 – Volt Comm on R 24 – Volt Hot W Full Stage Heat Y / Y2 Second or Full Stage Compressor SINGLE STAGE PSC FUR ...

  • Johnson Controls 13 SEER - GCGD - page 11

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 11 FIGURE 1 1: Thermostat Chart - Single S tage AC with PSC Furnace AC 5B Single Stage Air Conditioner – Single Stage PSC Furnace C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER SINGLE STAGE AIR CONDIT I O N ER Y Full Stage Compressor G Fan *BP11C50124 *BN11C01124 *D ...

  • Johnson Controls 13 SEER - GCGD - page 12

    1031452-UIM-B-0513 12 Johnson Controls Unitary Products SECTION IX: INSTRUCTING THE O WNER Assist owner with processing warr anty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance. I nstruct the owner or the opera- tor how to start, stop and adjust temperature sett ...

  • Johnson Controls 13 SEER - GCGD - page 13

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 13 SECTION X: WIRING DIAGRAM FIGURE 12: Wiring Diagram ...

  • Johnson Controls 13 SEER - GCGD - page 14

    1031452-UIM-B-0513 14 Johnson Controls Unitary Products NOTES ...

  • Johnson Controls 13 SEER - GCGD - page 15

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 15 SECTION XI: ST ART UP SHEET Air Conditioning and Heating Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity Name Address City State or Province Zip or Postal Code Indoor Unit Model # Indoor Unit Serial # Indoor Coil Model # Indoor Coil Serial # Upflow Downf ...

  • Johnson Controls 13 SEER - GCGD - page 16

    Subject to change without not ice. Published in U.S.A. 1031452-UIM-B-0513 Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 1031452-UIM-A-0413 Y ork Internat ional Corp. 5005 Y ork Driv e Norman, OK 73069 Supply static after indoor coil (in w.c.") Return Static (in w.c.") before filter Total External Static Pres ...

Fabricante Johnson Controls Categoría Air Conditioner

Los documentos del dispositivo Johnson Controls 13 SEER - GCGD que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Johnson Controls
- manuales de instrucciones 13 SEER - GCGD
- hojas de producto Johnson Controls
- folletos informativos
- o etiquetas energéticas Johnson Controls 13 SEER - GCGD
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Johnson Controls 13 SEER - GCGD.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Johnson Controls 13 SEER - GCGD, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Johnson Controls 13 SEER - GCGD. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Johnson Controls 13 SEER - GCGD.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Johnson Controls 13 SEER - GCGD, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Johnson Controls 13 SEER - GCGD. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Johnson Controls 13 SEER - GCGD.

El manual de instrucciones completo de Johnson Controls debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Johnson Controls 13 SEER - GCGD - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Johnson Controls 13 SEER - GCGD, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Johnson Controls 13 SEER - GCGD que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Johnson Controls 13 SEER - GCGD - que deben facilitarnos los primeros pasos durante el uso de Johnson Controls 13 SEER - GCGD
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Johnson Controls 13 SEER - GCGD
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Johnson Controls 13 SEER - GCGD en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Johnson Controls 13 SEER - GCGD?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Johnson Controls 13 SEER - GCGD, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Johnson Controls 13 SEER - GCGD probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)