    A TTENTION INST ALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation ...

  • Goodman Mfg RHA**B*D - page 2

    2 Safety Instructions Safety Guidelines 1. Allow only qualified, experienced technicians to install or service this unit. 2. Inst all the system in accordance with all local codes. If no local codes exist, follow National Codes (NEC in the U.S., CEC in Canada). 3. Open the electrical disconnect switch(es) before electrically connect- ing the unit. ...

  • Goodman Mfg RHA**B*D - page 3

    3 3 DO NOT locate the unit: – Directly under a vent termination for a gas appliance. – Within 3 feet of a clothes drier vent. – Where the refreezing of defrost water would create a hazard. – Where water may rise into the unit. – Where the noise would prove to be a nuisance to the customer (i.e. windows, patios, decks, etc.) DO locate the ...

  • Goodman Mfg RHA**B*D - page 4

    4 Safe Refrigerant Handling WARNING To avoid possible explosion, death, or injury; practice safe handling of refrigerants. While these items will not cover every conceivable situa- tion, they should serve as a useful guide. WARNING Refrigerants are heavier than air. They can “push out” the oxygen in your lungs or in any enclosed space. To avoid ...

  • Goodman Mfg RHA**B*D - page 5

    5 5 6. Close the valve on the nitrogen cylinder and discon- nect it from the gauge manifold. 7. Check for leaks. Apply a soap solution on all connec- tions and joints. If you see bubbles, you have a leak. Mark these locations. NOTE: If you use an electronic leak detector to test for leaks, add a trace of R-22 to the system (if permitted by current ...

  • Goodman Mfg RHA**B*D - page 6

    6 Step 2. Evacuate Lines And Indoor Coil. a. Open the high and low side valves (B & A) on the gauge manifold. NOTE: Only open the valve (E) on the gauge manifold leading to the cylinder, not the valve on the charging cylinder (F). b. Evacuate the system to about 29 inches Hg as mea- sured by the low side (compound) gauge. c. Open the valve (D) ...

  • Goodman Mfg RHA**B*D - page 7

    7 7 Electrical Connections 75 60 50 43 37 N/R N/R N/R N/R N/ R N/R N/R N/R 1 1 8 9 57 96 85 95 34 7 N / R N / R N / R N / R N / R N / R 1 8 8 1 5 0 1 2 5 1 0 7 9 58 37 56 86 3 5 85 4 N / R N / R 301 241 201 1 72 150 134 120 109 100 93 86 80 75 471 376 314 2 69 235 209 188 171 157 145 134 125 118 N/R = NO T RECOMMENDED W ire am pacity and voltage dr ...

  • Goodman Mfg RHA**B*D - page 8

    8 IMPORTANT: Hard start components are required when single-phase reciprocating compressors are used with indoor coils which have thermal expansion valves. Some units have hard start components factory installed. See the “Specification Sheet” for hard start component require- ments. System St artup PRELIMINARY CHARGE ADJUSTMENT CAUTION If this ...

  • Goodman Mfg RHA**B*D - page 9

    9 9 4 50 60 70 80 90 100 110 120 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 SUP E RHEAT @ O. D. U N IT O UTD OO R TE M P ER AT URE DESIR ED SUPERH EAT vs OU TDOOR TEMP ER AT URE 9 0 ° F I n d o o r 70° F I n d o o r 7 5 ° F I n d o o r 8 0 ° F I n d o o r 85 ° F I n d o o r ...

  • Goodman Mfg RHA**B*D - page 10

    10 ID COIL WITH EXPANSION VALVE At stabilized cooling conditions and with an outdoor tem- perature of 60°F or higher, the subcooling at the outdoor unit liquid line service valve should be as specified in the specification sheet. Add or remove charge as required. ID COIL WITH ORIFICE For a proper superheat reading, measure the refrigerant pressure ...

  • Goodman Mfg RHA**B*D - page 11

    11 11 THERMOST A T* CONNECTIONS T O RH/VH HEA T PUMPS WITH INDOOR BBA/BBC BLOWER COIL Approved Thermostat s: 1213403, 1213404, 1213410, 1213406 NOTE: 1. When installing accessories, wiring may have to be modified. Follow the instructions in the accessory kit’s installation instructions. WARNING To avoid personal injury, shock or death, disconnect ...

  • Goodman Mfg RHA**B*D - page 12

    12 Sy stem C hecklist 1 Does the cond enser f an blade r otate f reely, and is it tig ht on the s haft? 2 Does the ref rigeran t tubing flex f reely and not touc h anoth er tube to c ause r ub throug h? 3 Are bot h indoor and outdoor secti ons level? 4 Are t he units proper ly suppor ted? 5 Is out door sec tion prop erly located on c oncr ete base ...

Fabricante Goodman Mfg Categoría Heat Pump

Los documentos del dispositivo Goodman Mfg RHA**B*D que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Goodman Mfg
- manuales de instrucciones RHA**B*D
- hojas de producto Goodman Mfg
- folletos informativos
- o etiquetas energéticas Goodman Mfg RHA**B*D
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Goodman Mfg RHA**B*D.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Goodman Mfg RHA**B*D, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Goodman Mfg RHA**B*D. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Goodman Mfg RHA**B*D.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Goodman Mfg RHA**B*D, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Goodman Mfg RHA**B*D. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Goodman Mfg RHA**B*D.

El manual de instrucciones completo de Goodman Mfg debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Goodman Mfg RHA**B*D - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Goodman Mfg RHA**B*D, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Goodman Mfg RHA**B*D que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Goodman Mfg RHA**B*D - que deben facilitarnos los primeros pasos durante el uso de Goodman Mfg RHA**B*D
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Goodman Mfg RHA**B*D
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Goodman Mfg RHA**B*D en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Goodman Mfg RHA**B*D?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Goodman Mfg RHA**B*D, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Goodman Mfg RHA**B*D probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)