    A TTENTION INST ALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation ...

  • Goodman Mfg RHA**B*D - page 2

    2 Safety Instructions Safety Guidelines 1. Allow only qualified, experienced technicians to install or service this unit. 2. Inst all the system in accordance with all local codes. If no local codes exist, follow National Codes (NEC in the U.S., CEC in Canada). 3. Open the electrical disconnect switch(es) before electrically connect- ing the unit. ...

  • Goodman Mfg RHA**B*D - page 3

    3 3 DO NOT locate the unit: – Directly under a vent termination for a gas appliance. – Within 3 feet of a clothes drier vent. – Where the refreezing of defrost water would create a hazard. – Where water may rise into the unit. – Where the noise would prove to be a nuisance to the customer (i.e. windows, patios, decks, etc.) DO locate the ...

  • Goodman Mfg RHA**B*D - page 4

    4 Safe Refrigerant Handling WARNING To avoid possible explosion, death, or injury; practice safe handling of refrigerants. While these items will not cover every conceivable situa- tion, they should serve as a useful guide. WARNING Refrigerants are heavier than air. They can “push out” the oxygen in your lungs or in any enclosed space. To avoid ...

  • Goodman Mfg RHA**B*D - page 5

    5 5 6. Close the valve on the nitrogen cylinder and discon- nect it from the gauge manifold. 7. Check for leaks. Apply a soap solution on all connec- tions and joints. If you see bubbles, you have a leak. Mark these locations. NOTE: If you use an electronic leak detector to test for leaks, add a trace of R-22 to the system (if permitted by current ...

  • Goodman Mfg RHA**B*D - page 6

    6 Step 2. Evacuate Lines And Indoor Coil. a. Open the high and low side valves (B & A) on the gauge manifold. NOTE: Only open the valve (E) on the gauge manifold leading to the cylinder, not the valve on the charging cylinder (F). b. Evacuate the system to about 29 inches Hg as mea- sured by the low side (compound) gauge. c. Open the valve (D) ...

  • Goodman Mfg RHA**B*D - page 7

    7 7 Electrical Connections 75 60 50 43 37 N/R N/R N/R N/R N/ R N/R N/R N/R 1 1 8 9 57 96 85 95 34 7 N / R N / R N / R N / R N / R N / R 1 8 8 1 5 0 1 2 5 1 0 7 9 58 37 56 86 3 5 85 4 N / R N / R 301 241 201 1 72 150 134 120 109 100 93 86 80 75 471 376 314 2 69 235 209 188 171 157 145 134 125 118 N/R = NO T RECOMMENDED W ire am pacity and voltage dr ...

  • Goodman Mfg RHA**B*D - page 8

    8 IMPORTANT: Hard start components are required when single-phase reciprocating compressors are used with indoor coils which have thermal expansion valves. Some units have hard start components factory installed. See the “Specification Sheet” for hard start component require- ments. System St artup PRELIMINARY CHARGE ADJUSTMENT CAUTION If this ...

  • Goodman Mfg RHA**B*D - page 9

    9 9 4 50 60 70 80 90 100 110 120 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 SUP E RHEAT @ O. D. U N IT O UTD OO R TE M P ER AT URE DESIR ED SUPERH EAT vs OU TDOOR TEMP ER AT URE 9 0 ° F I n d o o r 70° F I n d o o r 7 5 ° F I n d o o r 8 0 ° F I n d o o r 85 ° F I n d o o r ...

  • Goodman Mfg RHA**B*D - page 10

    10 ID COIL WITH EXPANSION VALVE At stabilized cooling conditions and with an outdoor tem- perature of 60°F or higher, the subcooling at the outdoor unit liquid line service valve should be as specified in the specification sheet. Add or remove charge as required. ID COIL WITH ORIFICE For a proper superheat reading, measure the refrigerant pressure ...

  • Goodman Mfg RHA**B*D - page 11

    11 11 THERMOST A T* CONNECTIONS T O RH/VH HEA T PUMPS WITH INDOOR BBA/BBC BLOWER COIL Approved Thermostat s: 1213403, 1213404, 1213410, 1213406 NOTE: 1. When installing accessories, wiring may have to be modified. Follow the instructions in the accessory kit’s installation instructions. WARNING To avoid personal injury, shock or death, disconnect ...

  • Goodman Mfg RHA**B*D - page 12

    12 Sy stem C hecklist 1 Does the cond enser f an blade r otate f reely, and is it tig ht on the s haft? 2 Does the ref rigeran t tubing flex f reely and not touc h anoth er tube to c ause r ub throug h? 3 Are bot h indoor and outdoor secti ons level? 4 Are t he units proper ly suppor ted? 5 Is out door sec tion prop erly located on c oncr ete base ...

Fabricant Goodman Mfg Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilGoodman Mfg RHA**B*D peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman Mfg
- manuels d’utilisations RHA**B*D
- fiches produit Goodman Mfg
- dépliants
- ou étiquettes-énergie Goodman Mfg RHA**B*D
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman Mfg RHA**B*D.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman Mfg RHA**B*D, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman Mfg RHA**B*D. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman Mfg RHA**B*D.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goodman Mfg RHA**B*D, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman Mfg RHA**B*D par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman Mfg RHA**B*D.

Le manuel d’utilisation complet Goodman Mfg, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman Mfg RHA**B*D - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman Mfg RHA**B*D, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman Mfg RHA**B*D qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman Mfg RHA**B*D - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman Mfg RHA**B*D
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman Mfg RHA**B*D
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman Mfg RHA**B*D dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman Mfg RHA**B*D?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman Mfg RHA**B*D, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman Mfg RHA**B*D il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)