    A TTENTION INST ALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation ...

  • Goodman Mfg RHA**B*D - page 2

    2 Safety Instructions Safety Guidelines 1. Allow only qualified, experienced technicians to install or service this unit. 2. Inst all the system in accordance with all local codes. If no local codes exist, follow National Codes (NEC in the U.S., CEC in Canada). 3. Open the electrical disconnect switch(es) before electrically connect- ing the unit. ...

  • Goodman Mfg RHA**B*D - page 3

    3 3 DO NOT locate the unit: – Directly under a vent termination for a gas appliance. – Within 3 feet of a clothes drier vent. – Where the refreezing of defrost water would create a hazard. – Where water may rise into the unit. – Where the noise would prove to be a nuisance to the customer (i.e. windows, patios, decks, etc.) DO locate the ...

  • Goodman Mfg RHA**B*D - page 4

    4 Safe Refrigerant Handling WARNING To avoid possible explosion, death, or injury; practice safe handling of refrigerants. While these items will not cover every conceivable situa- tion, they should serve as a useful guide. WARNING Refrigerants are heavier than air. They can “push out” the oxygen in your lungs or in any enclosed space. To avoid ...

  • Goodman Mfg RHA**B*D - page 5

    5 5 6. Close the valve on the nitrogen cylinder and discon- nect it from the gauge manifold. 7. Check for leaks. Apply a soap solution on all connec- tions and joints. If you see bubbles, you have a leak. Mark these locations. NOTE: If you use an electronic leak detector to test for leaks, add a trace of R-22 to the system (if permitted by current ...

  • Goodman Mfg RHA**B*D - page 6

    6 Step 2. Evacuate Lines And Indoor Coil. a. Open the high and low side valves (B & A) on the gauge manifold. NOTE: Only open the valve (E) on the gauge manifold leading to the cylinder, not the valve on the charging cylinder (F). b. Evacuate the system to about 29 inches Hg as mea- sured by the low side (compound) gauge. c. Open the valve (D) ...

  • Goodman Mfg RHA**B*D - page 7

    7 7 Electrical Connections 75 60 50 43 37 N/R N/R N/R N/R N/ R N/R N/R N/R 1 1 8 9 57 96 85 95 34 7 N / R N / R N / R N / R N / R N / R 1 8 8 1 5 0 1 2 5 1 0 7 9 58 37 56 86 3 5 85 4 N / R N / R 301 241 201 1 72 150 134 120 109 100 93 86 80 75 471 376 314 2 69 235 209 188 171 157 145 134 125 118 N/R = NO T RECOMMENDED W ire am pacity and voltage dr ...

  • Goodman Mfg RHA**B*D - page 8

    8 IMPORTANT: Hard start components are required when single-phase reciprocating compressors are used with indoor coils which have thermal expansion valves. Some units have hard start components factory installed. See the “Specification Sheet” for hard start component require- ments. System St artup PRELIMINARY CHARGE ADJUSTMENT CAUTION If this ...

  • Goodman Mfg RHA**B*D - page 9

    9 9 4 50 60 70 80 90 100 110 120 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 SUP E RHEAT @ O. D. U N IT O UTD OO R TE M P ER AT URE DESIR ED SUPERH EAT vs OU TDOOR TEMP ER AT URE 9 0 ° F I n d o o r 70° F I n d o o r 7 5 ° F I n d o o r 8 0 ° F I n d o o r 85 ° F I n d o o r ...

  • Goodman Mfg RHA**B*D - page 10

    10 ID COIL WITH EXPANSION VALVE At stabilized cooling conditions and with an outdoor tem- perature of 60°F or higher, the subcooling at the outdoor unit liquid line service valve should be as specified in the specification sheet. Add or remove charge as required. ID COIL WITH ORIFICE For a proper superheat reading, measure the refrigerant pressure ...

  • Goodman Mfg RHA**B*D - page 11

    11 11 THERMOST A T* CONNECTIONS T O RH/VH HEA T PUMPS WITH INDOOR BBA/BBC BLOWER COIL Approved Thermostat s: 1213403, 1213404, 1213410, 1213406 NOTE: 1. When installing accessories, wiring may have to be modified. Follow the instructions in the accessory kit’s installation instructions. WARNING To avoid personal injury, shock or death, disconnect ...

  • Goodman Mfg RHA**B*D - page 12

    12 Sy stem C hecklist 1 Does the cond enser f an blade r otate f reely, and is it tig ht on the s haft? 2 Does the ref rigeran t tubing flex f reely and not touc h anoth er tube to c ause r ub throug h? 3 Are bot h indoor and outdoor secti ons level? 4 Are t he units proper ly suppor ted? 5 Is out door sec tion prop erly located on c oncr ete base ...

メーカー Goodman Mfg カテゴリー Heat Pump

Goodman Mfg RHA**B*Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RHA**B*Dの取扱説明書
- Goodman Mfgの製品カード
- パンフレット
- またはGoodman Mfg RHA**B*Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Goodman Mfg RHA**B*Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Goodman Mfg RHA**B*Dの取り付け説明書、サービスマニュアル、簡易説明書、またはGoodman Mfg RHA**B*Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Goodman Mfg RHA**B*Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Goodman Mfg RHA**B*Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGoodman Mfg RHA**B*Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのGoodman Mfg RHA**B*Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Goodman Mfgの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Goodman Mfg RHA**B*Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGoodman Mfg RHA**B*Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Goodman Mfg RHA**B*Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Goodman Mfg RHA**B*Dデバイスの基本機能を使うにあたってのヒント。 Goodman Mfg RHA**B*Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Goodman Mfg RHA**B*Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGoodman Mfg RHA**B*Dのメーカー/サービスへの連絡先に関する情報。

Goodman Mfg RHA**B*Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGoodman Mfg RHA**B*Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGoodman Mfg RHA**B*Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)