    SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved for use as a wood burning replace or for use wit ...

  • FMI S42 - page 2

    www .fmiproducts.com 1 1 1099-01L 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of th ...

  • FMI S42 - page 3

    www .fmiproducts.com 1 1 1099-01L 3 SPECIFICA TIONS 0" TO BOTTOM (LEFT SIDE ONL Y) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 66" X 20" TO PERPENDICULAR 12" EACH SIDE NOT LESS THAN 12" 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON ...

  • FMI S42 - page 4

    www .fmiproducts.com 1 1 1099-01L 4 FIREPLACE INST ALLA TION FRAMING 1.  Frame opening for the replace using dimensionsshowninFigures1and2. 2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring,? ...

  • FMI S42 - page 5

    www .fmiproducts.com 1 1 1099-01L 5 DRAIN P AN (DP42) Foroutdoor installations,thereplace enclo - sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the replace within the  ...

  • FMI S42 - page 6

    www .fmiproducts.com 1 1 1099-01L 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 44 " 12-8DM 12-8HT PipeSection 10 5 / 8 " 18-8DM 18-8HT PipeSection 16 5 / 8 " 24-8DM 24-8HT PipeSection 23 5 / 8 " 36-8DM 36-8HT PipeSection 34 5 / 8 " 48-8DM 48-8HT PipeSection 46 5 / 8 " ...

  • FMI S42 - page 7

    www .fmiproducts.com 1 1 1099-01L 7 VENTING INST ALLA TION Continued Continue to assemble chimney sections as outlined, making sure that both the inner and outer pipe sections are locked together . When  installing double wall snap-lock chimney together , it is important to assure the joint be- tween the ...

  • FMI S42 - page 8

    www .fmiproducts.com 1 1 1099-01L 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-8DM) Firestop spacers are required at each point where the chimney penetrates a oor space. Their purpose is to establish and maintain the required clearance b ...

  • FMI S42 - page 9

    www .fmiproducts.com 1 1 1099-01L 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45. ...

  • FMI S42 - page 10

    www .fmiproducts.com 1 1 1099-01L 10 T erminations with 16" slip pipe sections are available. TheRTT -8DM andRTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve the correct chimney height. ...

  • FMI S42 - page 11

    www .fmiproducts.com 1 1 1099-01L 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outsideof Fireplace GasLine Conduit Insulation Gas Conduit Cover 1/2"Dowel (see Figure 20, page 12). Note: Secure incoming gas line to wood fra ...

  • FMI S42 - page 12

    www .fmiproducts.com 1 1 1099-01L 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE ...

  • FMI S42 - page 13

    www .fmiproducts.com 1 1 1099-01L 13 DoorsFullyClosed FireplaceFront Doors FullyOpened FireplaceFront OPERA TION AND MAINTENANCE GUIDELINES Figure 21 - Glass Doors GLASS DOORS Glass doors are optional with the replace. When the replace is in operation, doors must be fully opened or full ...

  • FMI S42 - page 14

    www .fmiproducts.com 1 1 1099-01L 14 OPERA TION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER HANDLE OPERA TION The damper handle,which opens and closes the damper blade, is located in the upper front faceof thereplace. Pushingthehandle into the left of the keyway slot will free the damp ...

  • FMI S42 - page 15

    www .fmiproducts.com 1 1 1099-01L 15 KEY NO. P ART NO. DESCRIPTION QTY . 9 107812-03 LeftRefractory ,T exturedWhiteBrick • 1 108169-03 LeftRefractory ,T exturedWhiteHerringbone • 1 107812-02 LeftRefractory ,T exturedRedBrick • • 1 108169-02 LeftRefractory ,T exturedRedHerringbone • • 1 107 ...

  • FMI S42 - page 16

    www .fmiproducts.com 1 1 1099-01L 16 P ARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37/38 36 28 29 24 23 15 ...

  • FMI S42 - page 17

    www .fmiproducts.com 1 1 1099-01L 17 KEY NO. P ART NO. DESCRIPTION QTY . 1 107797-01 InsulationPan 1 2 ** FireplaceT op 1 3 107800-01 FireplaceSurround 1 4 106642-01 AirRodRetainer 1 5 106643-01 DamperRodRetainer 1 6 ** FireboxBottom 1 7 ** FireboxSurround 1 8 ** AirSeparator 1 9 SeePage15 LeftRefractory 1 ...

  • FMI S42 - page 18

    www .fmiproducts.com 1 1 1099-01L 18 ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM HOOD ST AINLESS STEEL - HS42 Requiredwhen installinga vent-free gas? ...

  • FMI S42 - page 19

    www .fmiproducts.com 1 1 1099-01L 19 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION - AK4F SQUARE CHASE-TOP TERMINA TION ET -8DM, ETO-8DM ECONO-TOP TERMINA TION WITH SLIP SECTION ETL-8DM, ETLO-8DM MESH ROUND ...

  • FMI S42 - page 20

    www .fmiproducts.com 1 1 1099-01L 20 1 1 1099-01 Rev .L 03/1 1 2701S.HarborBlvd. Santa Ana,CA 92704 1-866-328-4537 www .fmipr oducts.com ...

Fabricante FMI Categoría Indoor Fireplace

Los documentos del dispositivo FMI S42 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos FMI
- manuales de instrucciones S42
- hojas de producto FMI
- folletos informativos
- o etiquetas energéticas FMI S42
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones FMI S42.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje FMI S42, instrucciones de servicio, instrucciones cortas o instrucciones de usuario FMI S42. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto FMI S42.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo FMI S42, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar FMI S42. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de FMI S42.

El manual de instrucciones completo de FMI debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual FMI S42 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice FMI S42, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de FMI S42 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo FMI S42 - que deben facilitarnos los primeros pasos durante el uso de FMI S42
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con FMI S42
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de FMI S42 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de FMI S42?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con FMI S42, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con FMI S42 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)