    SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved for use as a wood burning replace or for use wit ...

  • FMI S42 - page 2

    www .fmiproducts.com 1 1 1099-01L 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of th ...

  • FMI S42 - page 3

    www .fmiproducts.com 1 1 1099-01L 3 SPECIFICA TIONS 0" TO BOTTOM (LEFT SIDE ONL Y) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 66" X 20" TO PERPENDICULAR 12" EACH SIDE NOT LESS THAN 12" 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON ...

  • FMI S42 - page 4

    www .fmiproducts.com 1 1 1099-01L 4 FIREPLACE INST ALLA TION FRAMING 1.  Frame opening for the replace using dimensionsshowninFigures1and2. 2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring,? ...

  • FMI S42 - page 5

    www .fmiproducts.com 1 1 1099-01L 5 DRAIN P AN (DP42) Foroutdoor installations,thereplace enclo - sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the replace within the  ...

  • FMI S42 - page 6

    www .fmiproducts.com 1 1 1099-01L 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 44 " 12-8DM 12-8HT PipeSection 10 5 / 8 " 18-8DM 18-8HT PipeSection 16 5 / 8 " 24-8DM 24-8HT PipeSection 23 5 / 8 " 36-8DM 36-8HT PipeSection 34 5 / 8 " 48-8DM 48-8HT PipeSection 46 5 / 8 " ...

  • FMI S42 - page 7

    www .fmiproducts.com 1 1 1099-01L 7 VENTING INST ALLA TION Continued Continue to assemble chimney sections as outlined, making sure that both the inner and outer pipe sections are locked together . When  installing double wall snap-lock chimney together , it is important to assure the joint be- tween the ...

  • FMI S42 - page 8

    www .fmiproducts.com 1 1 1099-01L 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-8DM) Firestop spacers are required at each point where the chimney penetrates a oor space. Their purpose is to establish and maintain the required clearance b ...

  • FMI S42 - page 9

    www .fmiproducts.com 1 1 1099-01L 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45. ...

  • FMI S42 - page 10

    www .fmiproducts.com 1 1 1099-01L 10 T erminations with 16" slip pipe sections are available. TheRTT -8DM andRTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve the correct chimney height. ...

  • FMI S42 - page 11

    www .fmiproducts.com 1 1 1099-01L 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outsideof Fireplace GasLine Conduit Insulation Gas Conduit Cover 1/2"Dowel (see Figure 20, page 12). Note: Secure incoming gas line to wood fra ...

  • FMI S42 - page 12

    www .fmiproducts.com 1 1 1099-01L 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE ...

  • FMI S42 - page 13

    www .fmiproducts.com 1 1 1099-01L 13 DoorsFullyClosed FireplaceFront Doors FullyOpened FireplaceFront OPERA TION AND MAINTENANCE GUIDELINES Figure 21 - Glass Doors GLASS DOORS Glass doors are optional with the replace. When the replace is in operation, doors must be fully opened or full ...

  • FMI S42 - page 14

    www .fmiproducts.com 1 1 1099-01L 14 OPERA TION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER HANDLE OPERA TION The damper handle,which opens and closes the damper blade, is located in the upper front faceof thereplace. Pushingthehandle into the left of the keyway slot will free the damp ...

  • FMI S42 - page 15

    www .fmiproducts.com 1 1 1099-01L 15 KEY NO. P ART NO. DESCRIPTION QTY . 9 107812-03 LeftRefractory ,T exturedWhiteBrick • 1 108169-03 LeftRefractory ,T exturedWhiteHerringbone • 1 107812-02 LeftRefractory ,T exturedRedBrick • • 1 108169-02 LeftRefractory ,T exturedRedHerringbone • • 1 107 ...

  • FMI S42 - page 16

    www .fmiproducts.com 1 1 1099-01L 16 P ARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37/38 36 28 29 24 23 15 ...

  • FMI S42 - page 17

    www .fmiproducts.com 1 1 1099-01L 17 KEY NO. P ART NO. DESCRIPTION QTY . 1 107797-01 InsulationPan 1 2 ** FireplaceT op 1 3 107800-01 FireplaceSurround 1 4 106642-01 AirRodRetainer 1 5 106643-01 DamperRodRetainer 1 6 ** FireboxBottom 1 7 ** FireboxSurround 1 8 ** AirSeparator 1 9 SeePage15 LeftRefractory 1 ...

  • FMI S42 - page 18

    www .fmiproducts.com 1 1 1099-01L 18 ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM HOOD ST AINLESS STEEL - HS42 Requiredwhen installinga vent-free gas? ...

  • FMI S42 - page 19

    www .fmiproducts.com 1 1 1099-01L 19 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION - AK4F SQUARE CHASE-TOP TERMINA TION ET -8DM, ETO-8DM ECONO-TOP TERMINA TION WITH SLIP SECTION ETL-8DM, ETLO-8DM MESH ROUND ...

  • FMI S42 - page 20

    www .fmiproducts.com 1 1 1099-01L 20 1 1 1099-01 Rev .L 03/1 1 2701S.HarborBlvd. Santa Ana,CA 92704 1-866-328-4537 www .fmipr oducts.com ...

Fabricant FMI Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilFMI S42 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques FMI
- manuels d’utilisations S42
- fiches produit FMI
- dépliants
- ou étiquettes-énergie FMI S42
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation FMI S42.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation FMI S42, manuels d’entretien, brefs manuels ou manuels de l’utilisateur FMI S42. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit FMI S42.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil FMI S42, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser FMI S42 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs FMI S42.

Le manuel d’utilisation complet FMI, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel FMI S42 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières FMI S42, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFMI S42 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil FMI S42 - qui devraient nous aider dans les premières étapes lors de l'utilisation FMI S42
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de FMI S42
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service FMI S42 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de FMI S42?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec FMI S42, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec FMI S42 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)