    SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved for use as a wood burning replace or for use wit ...

  • FMI S42 - page 2

    www .fmiproducts.com 1 1 1099-01L 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of th ...

  • FMI S42 - page 3

    www .fmiproducts.com 1 1 1099-01L 3 SPECIFICA TIONS 0" TO BOTTOM (LEFT SIDE ONL Y) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 66" X 20" TO PERPENDICULAR 12" EACH SIDE NOT LESS THAN 12" 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON ...

  • FMI S42 - page 4

    www .fmiproducts.com 1 1 1099-01L 4 FIREPLACE INST ALLA TION FRAMING 1.  Frame opening for the replace using dimensionsshowninFigures1and2. 2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring,? ...

  • FMI S42 - page 5

    www .fmiproducts.com 1 1 1099-01L 5 DRAIN P AN (DP42) Foroutdoor installations,thereplace enclo - sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the replace within the  ...

  • FMI S42 - page 6

    www .fmiproducts.com 1 1 1099-01L 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 44 " 12-8DM 12-8HT PipeSection 10 5 / 8 " 18-8DM 18-8HT PipeSection 16 5 / 8 " 24-8DM 24-8HT PipeSection 23 5 / 8 " 36-8DM 36-8HT PipeSection 34 5 / 8 " 48-8DM 48-8HT PipeSection 46 5 / 8 " ...

  • FMI S42 - page 7

    www .fmiproducts.com 1 1 1099-01L 7 VENTING INST ALLA TION Continued Continue to assemble chimney sections as outlined, making sure that both the inner and outer pipe sections are locked together . When  installing double wall snap-lock chimney together , it is important to assure the joint be- tween the ...

  • FMI S42 - page 8

    www .fmiproducts.com 1 1 1099-01L 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-8DM) Firestop spacers are required at each point where the chimney penetrates a oor space. Their purpose is to establish and maintain the required clearance b ...

  • FMI S42 - page 9

    www .fmiproducts.com 1 1 1099-01L 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45. ...

  • FMI S42 - page 10

    www .fmiproducts.com 1 1 1099-01L 10 T erminations with 16" slip pipe sections are available. TheRTT -8DM andRTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve the correct chimney height. ...

  • FMI S42 - page 11

    www .fmiproducts.com 1 1 1099-01L 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outsideof Fireplace GasLine Conduit Insulation Gas Conduit Cover 1/2"Dowel (see Figure 20, page 12). Note: Secure incoming gas line to wood fra ...

  • FMI S42 - page 12

    www .fmiproducts.com 1 1 1099-01L 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE ...

  • FMI S42 - page 13

    www .fmiproducts.com 1 1 1099-01L 13 DoorsFullyClosed FireplaceFront Doors FullyOpened FireplaceFront OPERA TION AND MAINTENANCE GUIDELINES Figure 21 - Glass Doors GLASS DOORS Glass doors are optional with the replace. When the replace is in operation, doors must be fully opened or full ...

  • FMI S42 - page 14

    www .fmiproducts.com 1 1 1099-01L 14 OPERA TION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER HANDLE OPERA TION The damper handle,which opens and closes the damper blade, is located in the upper front faceof thereplace. Pushingthehandle into the left of the keyway slot will free the damp ...

  • FMI S42 - page 15

    www .fmiproducts.com 1 1 1099-01L 15 KEY NO. P ART NO. DESCRIPTION QTY . 9 107812-03 LeftRefractory ,T exturedWhiteBrick • 1 108169-03 LeftRefractory ,T exturedWhiteHerringbone • 1 107812-02 LeftRefractory ,T exturedRedBrick • • 1 108169-02 LeftRefractory ,T exturedRedHerringbone • • 1 107 ...

  • FMI S42 - page 16

    www .fmiproducts.com 1 1 1099-01L 16 P ARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37/38 36 28 29 24 23 15 ...

  • FMI S42 - page 17

    www .fmiproducts.com 1 1 1099-01L 17 KEY NO. P ART NO. DESCRIPTION QTY . 1 107797-01 InsulationPan 1 2 ** FireplaceT op 1 3 107800-01 FireplaceSurround 1 4 106642-01 AirRodRetainer 1 5 106643-01 DamperRodRetainer 1 6 ** FireboxBottom 1 7 ** FireboxSurround 1 8 ** AirSeparator 1 9 SeePage15 LeftRefractory 1 ...

  • FMI S42 - page 18

    www .fmiproducts.com 1 1 1099-01L 18 ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM HOOD ST AINLESS STEEL - HS42 Requiredwhen installinga vent-free gas? ...

  • FMI S42 - page 19

    www .fmiproducts.com 1 1 1099-01L 19 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION - AK4F SQUARE CHASE-TOP TERMINA TION ET -8DM, ETO-8DM ECONO-TOP TERMINA TION WITH SLIP SECTION ETL-8DM, ETLO-8DM MESH ROUND ...

  • FMI S42 - page 20

    www .fmiproducts.com 1 1 1099-01L 20 1 1 1099-01 Rev .L 03/1 1 2701S.HarborBlvd. Santa Ana,CA 92704 1-866-328-4537 www .fmipr oducts.com ...

Manufacturer FMI Category Indoor Fireplace

Documents that we receive from a manufacturer of a FMI S42 can be divided into several groups. They are, among others:
- FMI technical drawings
- S42 manuals
- FMI product data sheets
- information booklets
- or energy labels FMI S42
All of them are important, but the most important information from the point of view of use of the device are in the user manual FMI S42.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FMI S42, service manual, brief instructions and user manuals FMI S42. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FMI S42.

Similar manuals

A complete manual for the device FMI S42, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FMI S42 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FMI S42.

A complete FMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FMI S42 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FMI S42, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FMI S42, that we can find in the current document
3. Tips how to use the basic functions of the device FMI S42 - which should help us in our first steps of using FMI S42
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FMI S42
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FMI S42 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FMI S42?

Use the form below

If you did not solve your problem by using a manual FMI S42, ask a question using the form below. If a user had a similar problem with FMI S42 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)