Manual de instrucciones Coleman PM402511

32 de páginas 1.4 mb
Descargar

Pasar a la página of 32

Summary
  • Coleman PM402511 - page 1

    © 2003 ÂColeman Powermate, Inc. 12-03 S t ationary S t andby Electric Generator - 25,000 W A TTS I MPORT ANT SAFETY INSTRUCTIONS – Please make cert ain that persons who are to inst all, operate and maint ain this equipment thoroughly read and underst and these instructions prior to operation. SA VE THESE INSTRUCTIONS — This manual cont ains i ...

  • Coleman PM402511 - page 2

    Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Introduction . . . . . . . . . . . . ...

  • Coleman PM402511 - page 3

    Do not attempt to install the generator yourself. Extremely high and dangerous electrical voltages are present in utility power source lines and in generator load leads when the unit is running. Therefore, be sure to turn OFF all power voltage supplies at their source before attempting to complete electrical connections. Only qualified installation ...

  • Coleman PM402511 - page 4

    The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground. Keep a fire extinguisher near the generator at all times. Extinguishers rated "ABC" by the National Fire Protection Association are appropriate for use on the standby electric syste ...

  • Coleman PM402511 - page 5

    The stationary standby electric generator is manufactured for our customers to supply reliable backup power. The generator is a compact unit, designed to supply the power for your critical needs when utility power fails. The standby generator will run on Liquid Propane Gas or Natural Gas allowing flexibility for getting the power you need. Fuel lin ...

  • Coleman PM402511 - page 6

    Rated W attage - (S tandby) 25,000 W atts@1.0PF LPG 22,000 W atts @ 1.0 PF NG V oltage - 120/240 volts Rated Current - 208/104 amps LPG Frequency - 60 HZ Power Factor - 1.0 Max. Ambient T emp Rise - 105°C Insulation class - H Note: Rated wattage is specified at sea level, 60°F ambient temperature, and prop ane fuel (with 2500 BTU/cuft). Rated wat ...

  • Coleman PM402511 - page 7

    I I N N S S T T A A L L L L A A T T I I O O N N D D R R A A W W I I N N G G S S 7 ...

  • Coleman PM402511 - page 8

    NOTE: The generator frame has been designed with rectangular slots and frame tubes to be used with a forklift for removing the unit from the pallet and positioning the unit on the cement pad. NOTE: The generator has an engine fan that draws the air in from the side panel slots, circulates it within the enclosure and forces the air through the radia ...

  • Coleman PM402511 - page 9

    L L O O C C A A T T I I O O N N A A N N D D G G E E N N E E R R A A T T O O R R P P L L A A C C E E M M E E N N T T ( ( c c o o n n t t i i n n u u e e d d ) ) W W A A R R N N I I N N G G • For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulatio ...

  • Coleman PM402511 - page 10

    NATURAL GAS (NG) SETTINGS Units are tested with natural gas before they leave the factory. If natural gas is to be used, no adjustments are required. The fuel select switch, located on the bottom of the control panel, should be in the (NG) position. The (NG) position is with the switch depressed away from the front of the control panel (see A in il ...

  • Coleman PM402511 - page 11

    This generator must be connected to an automatic transfer switch. The automatic transfer switch detects when a power failure occurs and automatically starts the engine to provide generator power. When the utility power becomes available, the transfer switch automatically shuts down the generator and switches back to the utility power. (See figure 1 ...

  • Coleman PM402511 - page 12

    Minimum recommended battery size is a BCI Group 26 with a minimum of 550 CCA (Cold Cranking Amps). Place the battery in the battery rack as shown and secure using the holddown hardware provided. Once the battery has been placed and tied down with the battery hold down bar, connect the leads to the respective battery post. Always connect the (red) p ...

  • Coleman PM402511 - page 13

    Check oil level before start-up. The unit is shipped with the proper type of oil in the crankcase for operation above 40°F. Follow the engine manufacturer’s recommendations for oil at temperatures below 40°F. Check oil periodically to ensure that the unit is properly lubricated. Follow the engine manufacturer’s recommended service schedule. E ...

  • Coleman PM402511 - page 14

    A Two line by twenty character LCD provides the primary visual interface for metering, alarms, pre- alarms and protective functions. In the normal mode, labels appear above and below the display. In the alternate display mode, labels and the displayed value appear on the display. B Red LED turns ON when the device is not in the AUTO mode. C Red LED ...

  • Coleman PM402511 - page 15

    DISPLAY MODE Pressing the Display/Toggle pushbutton allows the user to scroll through the Normal, Alternate and Menu display Modes. ALTERNATE DISPLAY MODE Alternate Display Mode can be used to observe generator performance including oil pressure, coolant temperature, battery voltage, kilowatt load, generator voltage, kVA, hours to next service, amp ...

  • Coleman PM402511 - page 16

    When the generator control panel senses an abnormal operating condition, an alarm is declared and the generator set is shutdown. All alarm conditions will light a red LED (labeled Alarm ) along with displaying the condition on the LCD screen. When an alarm condition occurs, the display indicates the cause of the alarm and the fuel solenoid contact ...

  • Coleman PM402511 - page 17

    2 2 5 5 K K W W W W I I R R I I N N G G D D I I A A G G R R A A M M ( ( C C P P 5 5 0 0 0 0 C C O O N N T T R R O O L L L L E E R R ) ) SCHÉMA DE CÂBLAGE 25KW (CONTRÔLEUR CP 500) DIAGRAMA DE CIRCUITO ELÉCTRICO DE 25 KILOV A TIOS (CONTROLADOR CP500) 17 ...

  • Coleman PM402511 - page 18

    2 2 5 5 K K W W W W I I R R I I N N G G D D I I A A G G R R A A M M ( ( C C P P 1 1 0 0 0 0 0 0 C C O O N N T T R R O O L L L L E E R R ) ) SCHÉMA DE CÂBLAGE 25KW (CONTRÔLEUR CP 1000) DIAGRAMA DE CIRCUITO ELÉCTRICO DE 25 KILOV A TIOS (CONTROLADOR CP1000) 18 ...

  • Coleman PM402511 - page 19

    • Check oil every 8 hours of operation. • Change oil and oil filter every 100 hours of operation. • Change air filter every 400 hours. • Replace spark plugs every 500 hours . • Check Coolant level every 8 hours of operation. Check coolant mixture at least twice a year using a hygrometer. • Check battery terminals at least twice a year. ...

  • Coleman PM402511 - page 20

    SYMPTOM Engine will not crank in Manual mode. Engine will crank in manual mode but will not start. Engine runs but no A.C. output from the generator. Fault light on, engine will not start. Engine starts but shuts down immediately. Battery will not stay charged. Engine will not run at full speed or runs rough. POSSIBLE CAUSE 1. Defective Battery. 2. ...

  • Coleman PM402511 - page 21

    Coleman PowerSt ation™ St ationary S t andby 3-Y ear or 1500 Hour Limited W arranty Your Coleman PowerStation™ emergency back up power system generator has been manufactured to stringent guidelines & standards for years of dependable operation & service. Coleman Powermate warrants this product to the original consumer against defects in ...

  • Coleman PM402511 - page 22

    Hour Maintenance Performed Meter Time Hour Maintenance Performed Meter Time M M A A I I N N T T E E N N A A N N C C E E L L O O G G Always follow the engine manufactures recommendations when performing maintenance. Use this page to track the maintenance which is performed. Noting the time on the hour meter will help in keeping the maintenance sched ...

  • Coleman PM402511 - page 23

    P P A A R R T T S S D D R R A A W W I I N N G G - - E E X X H H A A U U S S T T S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME D'ÉCHAPPEMENT DIAGRAMA DE PIEZAS - SISTEMA DE ESCAPE P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 0058015 1 Tailpipe . . . . . . . . . . . . . . . . . . . . . . . Embout d'éc ...

  • Coleman PM402511 - page 24

    P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS P P A A R R T T S S D D R R A A W W I I N N G G - - E E N N C C L L O O S S U U R R E E PLAN DES PIÈCES - BOÎTIER DIAGRAMA DE PIEZAS - CARCASA 24 1 115-0206 1 Lid assembly (includes lid and . . . . . . Couvercle (incluant l'isolant sonore) . Conjunto de tapa (incluye ...

  • Coleman PM402511 - page 25

    P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O O O L L I I N N G G S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME DE REFROIDISSEMENT DIAGRAMA DE PIEZAS - SISTEMA DE ENFRIAMIENTO 25 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 115-0211 1 Radiator panel . . . . . . . . . . . . . . . . . . Panneau de rad ...

  • Coleman PM402511 - page 26

    P P A A R R T T S S D D R R A A W W I I N N G G - - D D O O O O R R A A S S S S E E M M B B L L Y Y PLAN DES PIÈCES - ENSEMBLE DE PORTE ESQUEMA DE PIEZAS - CONJUNTO DE LA PUERT A 26 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 See page 24 1 Door assembly . . . . . . . . . . . . . . . . . . Ensemble de porte (voir pa ...

  • Coleman PM402511 - page 27

    P P A A R R T T S S D D R R A A W W I I N N G G - - F F U U E E L L S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME D'ADMISSION DIAGRAMA DE PIEZAS - SISTEMA DE COMBUSTIBLE Item Art Art 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *N/A NOTE: Seal all connections with gas tape. Use 2½ wraps minimum. Check all connections under pressure using a soa ...

  • Coleman PM402511 - page 28

    P P A A R R T T S S D D R R A A W W I I N N G G - - G G E E N N E E R R A A T T O O R R PLAN DES PIÈCES - GÉNÉRA TRICE DIAGRAMA DE PIEZAS - GENERADOR 28 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 0059337 1 Rectifier service kit w/var, dio . . . . . . Ens. de réparation redresseur . . . . . Juego de rectificaci? ...

  • Coleman PM402511 - page 29

    P P A A R R T T S S D D R R A A W W I I N N G G - - 2 2 5 5 K K W W B B R R E E A A K K D D O O W W N N PLAN DES PIÈCES - VUE ÉCLA TÉE 25 KW DIAGRAMA DE PIEZAS - DESGLOSE DEL MODELO DE 25 KILOV A TIOS 29 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 059-0332 4 Bolt, M10-1.5 X 25MM . . . . . . . . . . . . Boulon, M10- ...

  • Coleman PM402511 - page 30

    P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O N N T T R R O O L L P P A A N N E E L L E E N N D D A A S S S S E E M M B B L L Y Y PLAN DES PIÈCES - ENSEMBLE DE T ABLEAU DE COMMANDE DIAGRAMA DE PIEZAS - CONJUNTO TERMINAL DEL P ANEL DE CONTROL 30 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 115-0213 1 Gene ...

  • Coleman PM402511 - page 31

    P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O N N T T R R O O L L P P A A N N E E L L B B R R E E A A K K D D O O W W N N PLAN DES PIÈCES - VUE ÉCLA TÉE DU T ABLEAU DE COMMANDE DIAGRAMA DE PIEZAS - DESGLOSE DEL P ANEL DE CONTROL 31 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 N/A 4 Nut, 1/4-20 nylon st ...

  • Coleman PM402511 - page 32

    P P A A R R T T S S D D R R A A W W I I N N G G - - B B A A T T T T E E R R Y Y H H O O L L D D D D O O W W N N PLAN DES PIÈCES - FIXA TION DE LA BA TTERIE DIAGRAMA DE PIEZAS - SUJECIÓN DE LA BA TERÍA 32 To Starter Au Démarreur Al Arrancador To Engine Block Au Bloc De Moteur Al Bloque Del Motor P P A A R R T T S S L L I I S S T T LISTE DES PIÈ ...

Fabricante Coleman Categoría Portable Generator

Los documentos del dispositivo Coleman PM402511 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Coleman
- manuales de instrucciones PM402511
- hojas de producto Coleman
- folletos informativos
- o etiquetas energéticas Coleman PM402511
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Coleman PM402511.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Coleman PM402511, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Coleman PM402511. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Coleman PM402511.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Coleman PM402511, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Coleman PM402511. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Coleman PM402511.

El manual de instrucciones completo de Coleman debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Coleman PM402511 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Coleman PM402511, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Coleman PM402511 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Coleman PM402511 - que deben facilitarnos los primeros pasos durante el uso de Coleman PM402511
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Coleman PM402511
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Coleman PM402511 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Coleman PM402511?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Coleman PM402511, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Coleman PM402511 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)