Manual de instrucciones Quantum Data 822S

12 de páginas 0.46 mb
Descargar

Pasar a la página of 12

Summary
  • Quantum Data 822S - page 1

    68-00183 Re v. C Quantum Data, Inc. Page 1 M ODEL 822S Programmable Monochrome Video Signal Generator Quantum Data, Inc. T able of Contents Making Connections .... 2 Proper Video Termination ................... 3 Front Panel Operation ... 4 Special Operating Mode (Probe Pulse) ..... 5 Special Operating Mode (Reinitializing Memory) ................. ...

  • Quantum Data 822S - page 2

    Page 2 Model 822S Quick Start Guide Making Connections (Power & Test Signals) AC Mains Input & Switch 85 - 264 VAC 48 - 440 Hz Sine 300 Watts Max. Analog Video Output 50 Ohm Differential Analog Output Level Calibration Inputs Blank module for Model 822S Video Module - Monochrome Output Blank module for Model 822S Vertical and Horizontal Syn ...

  • Quantum Data 822S - page 3

    68-00183 Re v. C Quantum Data, Inc. Page 3 Proper Video Termination Improper termination of the video outputs will result in degradation (ringing, undershoot and/or overshoot) of the test signals . The following figures show suggested methods for connecting the video generator to displays having 50 and 75 Ohm input impedances in both differential a ...

  • Quantum Data 822S - page 4

    Page 4 Model 822S Quick Start Guide Front Panel Operation (Normal Mode) Format Knob Selects a signal format from knob list. Image Knob Selects a test image (pattern) from knob list. Outputs Button T urns all signal outputs on and off Sync Gate Buttons T urn different sync types on and off Video Gate Buttons T urn individual video elements on and of ...

  • Quantum Data 822S - page 5

    68-00183 Re v. C Quantum Data, Inc. Page 5 Special Operating Modes Probe Sync Pulse Output The FS connector on the sync module can output a TTL Level probe pulse that can be used to trigger an oscilloscope or to synchronize a camera used in automated vision systems. The pulse can be positioned manually by the operator or by commands sent by a test ...

  • Quantum Data 822S - page 6

    Page 6 Model 822S Quick Start Guide Special Operating Modes Probe Sync Pulse Output (Continued) There are two additional Probe Pulse operating modes available when outputting a progressive (non- interlaced) video format. Pressing the “R” video gating button will produce a probe pulse for each scan line that contains active video. The bottom row ...

  • Quantum Data 822S - page 7

    68-00183 Re v. C Quantum Data, Inc. Page 7 Special Operating Modes Reinitializing Memory ! Reinitializing the generator ’s memory erases all user created data and sets all video ampli- tude calibration factors to 0.000. This will disable the video outputs until self calibration is performed. 1) The easiest way to start the procedure is to use the ...

  • Quantum Data 822S - page 8

    Page 8 Model 822S Quick Start Guide Y ou can also start the procedure by sending the following command string to the generator’s comm port while the unit is running: AVCM 1; fmtu <carriage return> Details on the connections can be found on a later page. 2) The LCD will display a prompt asking you to make the connections for calibration. 5) ...

  • Quantum Data 822S - page 9

    68-00183 Re v. C Quantum Data, Inc. Page 9 Programming and Operation via Computer Computer Data Po rts: RS-232 (9 pin male D-Sub) 2400 Baud (factory default) 8 Data Bits / 1 Stop Bit / No Parity Pin #2 Data in / Pin #3 Data out Pin #4 DTR in Pin #7 RTS out / Pin #8 CTS in GPIB (24 pin micro-ribbon recept.) Protocol: IEEE-488.2 NOTE: GPIB address sw ...

  • Quantum Data 822S - page 10

    Page 10 Model 822S Quick Start Guide Video Timing Pixel Clock: Range: 7.5 MHz - 600 (optionally 800 MHz) Step: < 0.25 Hz Jitter: < 60 pS line to line (One Sigma) Accuracy: 25 ppm (electronically trimmable to 0 ppm Horizontal Timing Frequency: 1 KHz - 330 KHz T ypical T otal pixels per line: Range: 128 to 65,535 Pixels Step: 1 Pixel (4 Pixels, ...

  • Quantum Data 822S - page 11

    68-00183 Re v. C Quantum Data, Inc. Page 11 User Interface Front Panel: 16 x 2 character LCD LED backlight Format & image selector knobs Invert, video gate, sync gate, output on/off buttons MS-Windows 95/98, NT: Virtual front panel Format, image& sequence editors File management Configure (start-up) file editor MS-DOS Command line: T ermina ...

  • Quantum Data 822S - page 12

    Page 12 Model 822S Quick Start Guide Quantum Data, Inc. 2111 Big Timber Rd. Elgin, IL 60123-1100 USA Main T el: (847) 888-0450 Facsimile: (847) 888-2802 Website: www.quantumdata.com Product Support and Service T oll free telephone number in USA 1-888-252-6133 From all other countries: [1] 847-888-0450 then select option 3 E-Mail: support@quantumdat ...

Fabricante Quantum Data Categoría Projector

Los documentos del dispositivo Quantum Data 822S que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Quantum Data
- manuales de instrucciones 822S
- hojas de producto Quantum Data
- folletos informativos
- o etiquetas energéticas Quantum Data 822S
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Quantum Data 822S.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Quantum Data 822S, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Quantum Data 822S. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Quantum Data 822S.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Quantum Data 822S, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Quantum Data 822S. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Quantum Data 822S.

El manual de instrucciones completo de Quantum Data debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Quantum Data 822S - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Quantum Data 822S, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Quantum Data 822S que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Quantum Data 822S - que deben facilitarnos los primeros pasos durante el uso de Quantum Data 822S
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Quantum Data 822S
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Quantum Data 822S en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Quantum Data 822S?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Quantum Data 822S, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Quantum Data 822S probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)