Manuale per l’uso Quantum Data 822S

12 pagine 0.46 mb
Scarica

Vai alla pagina of 12

Summary
  • Quantum Data 822S - page 1

    68-00183 Re v. C Quantum Data, Inc. Page 1 M ODEL 822S Programmable Monochrome Video Signal Generator Quantum Data, Inc. T able of Contents Making Connections .... 2 Proper Video Termination ................... 3 Front Panel Operation ... 4 Special Operating Mode (Probe Pulse) ..... 5 Special Operating Mode (Reinitializing Memory) ................. ...

  • Quantum Data 822S - page 2

    Page 2 Model 822S Quick Start Guide Making Connections (Power & Test Signals) AC Mains Input & Switch 85 - 264 VAC 48 - 440 Hz Sine 300 Watts Max. Analog Video Output 50 Ohm Differential Analog Output Level Calibration Inputs Blank module for Model 822S Video Module - Monochrome Output Blank module for Model 822S Vertical and Horizontal Syn ...

  • Quantum Data 822S - page 3

    68-00183 Re v. C Quantum Data, Inc. Page 3 Proper Video Termination Improper termination of the video outputs will result in degradation (ringing, undershoot and/or overshoot) of the test signals . The following figures show suggested methods for connecting the video generator to displays having 50 and 75 Ohm input impedances in both differential a ...

  • Quantum Data 822S - page 4

    Page 4 Model 822S Quick Start Guide Front Panel Operation (Normal Mode) Format Knob Selects a signal format from knob list. Image Knob Selects a test image (pattern) from knob list. Outputs Button T urns all signal outputs on and off Sync Gate Buttons T urn different sync types on and off Video Gate Buttons T urn individual video elements on and of ...

  • Quantum Data 822S - page 5

    68-00183 Re v. C Quantum Data, Inc. Page 5 Special Operating Modes Probe Sync Pulse Output The FS connector on the sync module can output a TTL Level probe pulse that can be used to trigger an oscilloscope or to synchronize a camera used in automated vision systems. The pulse can be positioned manually by the operator or by commands sent by a test ...

  • Quantum Data 822S - page 6

    Page 6 Model 822S Quick Start Guide Special Operating Modes Probe Sync Pulse Output (Continued) There are two additional Probe Pulse operating modes available when outputting a progressive (non- interlaced) video format. Pressing the “R” video gating button will produce a probe pulse for each scan line that contains active video. The bottom row ...

  • Quantum Data 822S - page 7

    68-00183 Re v. C Quantum Data, Inc. Page 7 Special Operating Modes Reinitializing Memory ! Reinitializing the generator ’s memory erases all user created data and sets all video ampli- tude calibration factors to 0.000. This will disable the video outputs until self calibration is performed. 1) The easiest way to start the procedure is to use the ...

  • Quantum Data 822S - page 8

    Page 8 Model 822S Quick Start Guide Y ou can also start the procedure by sending the following command string to the generator’s comm port while the unit is running: AVCM 1; fmtu <carriage return> Details on the connections can be found on a later page. 2) The LCD will display a prompt asking you to make the connections for calibration. 5) ...

  • Quantum Data 822S - page 9

    68-00183 Re v. C Quantum Data, Inc. Page 9 Programming and Operation via Computer Computer Data Po rts: RS-232 (9 pin male D-Sub) 2400 Baud (factory default) 8 Data Bits / 1 Stop Bit / No Parity Pin #2 Data in / Pin #3 Data out Pin #4 DTR in Pin #7 RTS out / Pin #8 CTS in GPIB (24 pin micro-ribbon recept.) Protocol: IEEE-488.2 NOTE: GPIB address sw ...

  • Quantum Data 822S - page 10

    Page 10 Model 822S Quick Start Guide Video Timing Pixel Clock: Range: 7.5 MHz - 600 (optionally 800 MHz) Step: < 0.25 Hz Jitter: < 60 pS line to line (One Sigma) Accuracy: 25 ppm (electronically trimmable to 0 ppm Horizontal Timing Frequency: 1 KHz - 330 KHz T ypical T otal pixels per line: Range: 128 to 65,535 Pixels Step: 1 Pixel (4 Pixels, ...

  • Quantum Data 822S - page 11

    68-00183 Re v. C Quantum Data, Inc. Page 11 User Interface Front Panel: 16 x 2 character LCD LED backlight Format & image selector knobs Invert, video gate, sync gate, output on/off buttons MS-Windows 95/98, NT: Virtual front panel Format, image& sequence editors File management Configure (start-up) file editor MS-DOS Command line: T ermina ...

  • Quantum Data 822S - page 12

    Page 12 Model 822S Quick Start Guide Quantum Data, Inc. 2111 Big Timber Rd. Elgin, IL 60123-1100 USA Main T el: (847) 888-0450 Facsimile: (847) 888-2802 Website: www.quantumdata.com Product Support and Service T oll free telephone number in USA 1-888-252-6133 From all other countries: [1] 847-888-0450 then select option 3 E-Mail: support@quantumdat ...

Fabbricante Quantum Data Categoria Projector

I documenti che otteniamo dal fabbricante del dispositivoQuantum Data 822S possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Quantum Data
- manuali per l’uso 822S
- schede prodotto Quantum Data
- opuscoli
- o etichette energetiche Quantum Data 822S
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Quantum Data 822S.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Quantum Data 822S, manuali di manutenzione, brevi manuali o manuali utente Quantum Data 822S. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Quantum Data 822S.

Manuali per l’uso simili

Manuale completo del dispositivo Quantum Data 822S, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Quantum Data 822S dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Quantum Data 822S.

Il manuale per l’uso completo Quantum Data, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Quantum Data 822S - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Quantum Data 822S, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Quantum Data 822S che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Quantum Data 822S - che ci dovrebbe aiutare nei primi passi durante l'uso Quantum Data 822S
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Quantum Data 822S
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Quantum Data 822S in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Quantum Data 822S?

Utilizza il modulo sottostante

Se non hai risolto il problema con Quantum Data 822S con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Quantum Data 822S è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)