    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 3

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 4

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 5

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 6

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 7

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 8

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 9

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P AGING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this confi ...

  • Bogen PCM2000 - page 10

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 11

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 12

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defa ...

  • Bogen PCM2000 - page 13

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 14

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 15

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 16

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 17

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 18

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 19

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 20

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 21

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 22

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 23

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 24

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 25

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 26

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 27

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defau ...

  • Bogen PCM2000 - page 28

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 29

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 30

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P A GING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this conf ...

  • Bogen PCM2000 - page 31

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 32

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 33

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 34

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 35

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 36

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 37

    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 38

    PCM2000 Configuration Guide 50 Spring Street, Ramsey , NJ 07446 U.S.A. T el. 20 1 -934-8500 / Fax 20 1 -934-9832/ www .bogen.com ...

Fabricante Bogen Categoría Ventilation Hood

Los documentos del dispositivo Bogen PCM2000 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bogen
- manuales de instrucciones PCM2000
- hojas de producto Bogen
- folletos informativos
- o etiquetas energéticas Bogen PCM2000
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bogen PCM2000.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bogen PCM2000, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bogen PCM2000. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bogen PCM2000.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bogen PCM2000, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bogen PCM2000. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bogen PCM2000.

El manual de instrucciones completo de Bogen debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bogen PCM2000 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bogen PCM2000, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bogen PCM2000 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bogen PCM2000 - que deben facilitarnos los primeros pasos durante el uso de Bogen PCM2000
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bogen PCM2000
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bogen PCM2000 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bogen PCM2000?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bogen PCM2000, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bogen PCM2000 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)