  • Bogen PCM2000 - page 1

    PCM2000 Configuration Guide 50 Spring Street, Ramsey , NJ 07446 U.S.A. T el. 20 1 -934-8500 / Fax 20 1 -934-9832/ www .bogen.com : http://www. guardianalarms . net ...

  • Bogen PCM2000 - page 2

    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 3

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 4

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 5

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 6

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 7

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 8

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 9

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P AGING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this confi ...

  • Bogen PCM2000 - page 10

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 11

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 12

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defa ...

  • Bogen PCM2000 - page 13

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 14

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 15

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 16

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 17

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 18

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 19

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 20

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 21

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 22

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 23

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 24

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 25

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 26

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 27

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defau ...

  • Bogen PCM2000 - page 28

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 29

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 30

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P A GING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this conf ...

  • Bogen PCM2000 - page 31

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 32

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 33

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 34

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 35

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 36

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 37

    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 38

    PCM2000 Configuration Guide 50 Spring Street, Ramsey , NJ 07446 U.S.A. T el. 20 1 -934-8500 / Fax 20 1 -934-9832/ www .bogen.com ...

メーカー Bogen カテゴリー Ventilation Hood

Bogen PCM2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PCM2000の取扱説明書
- Bogenの製品カード
- パンフレット
- またはBogen PCM2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bogen PCM2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bogen PCM2000の取り付け説明書、サービスマニュアル、簡易説明書、またはBogen PCM2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bogen PCM2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bogen PCM2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBogen PCM2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのBogen PCM2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bogenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bogen PCM2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBogen PCM2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bogen PCM2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bogen PCM2000デバイスの基本機能を使うにあたってのヒント。 Bogen PCM2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bogen PCM2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBogen PCM2000のメーカー/サービスへの連絡先に関する情報。

Bogen PCM2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBogen PCM2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBogen PCM2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)