    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 3

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 4

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 5

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 6

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 7

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 8

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 9

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P AGING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this confi ...

  • Bogen PCM2000 - page 10

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 11

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 12

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defa ...

  • Bogen PCM2000 - page 13

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 14

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 15

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 16

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 17

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 18

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 19

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 20

    CONFIGURA TION 9: 3-ZONE - ONE-W A Y P AGING - LO W -PO WER SY STEM - DEDICA TED AMPLIFIERS OR SELF-AMPLIFIED SPEAKERS Low-P ow er System is a switch-selectable f eature that allo ws the system designer to use dedicated amplifiers or self-amplified speak ers on the zone outputs. The PCMZPM module that is to be used as a low-pow er module will switc ...

  • Bogen PCM2000 - page 21

    CONFIGURA TION 8: TW O-W A Y T ALK BA CK EXTENDED P AGING SYSTEM This configuration is essentially the same as the tw o-wa y paging system described previously on page 1 7. The main difference is the addition of a satellite assembly . The requir ed setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2 Note: T alk Back is only availab le ...

  • Bogen PCM2000 - page 22

    CONFIGURA TION 1 0: 6 ZONES - ONE-W A Y P A GING - MIXED HIGH- AND LO W -PO WER ZONES - 25/70V A C OR SELF-AMPLIFIED SPEAKERS High- and Low-P ow er Mix ed System is a non-programmable featur e that lets the system designer use a dedicated amplifier or self-amplified speak er per zone and at the same time use a centralized amplifier for zones r equi ...

  • Bogen PCM2000 - page 23

    CONFIGURA TION 7: TW O-W A Y T ALK BA CK P A GING SYSTEM This configuration is essentially the same as the one-wa y paging system described previousl y . The main difference between the on e-wa y con- figuration and this configuration is that the centralized high-pow er amplifier is connected to the PCMTBM module instead of the PCMCPU module. The r ...

  • Bogen PCM2000 - page 24

    CONFIGURA TION 11 : MICROPHONE O VERRIDE Microphone Ov erride is a feature that lets the system designer tak e priority over all paging functions and mak e a system-wide page to all speak ers. In addition to the PCM modules, setup r equires a Bogen V AR 1 (voice-activated rela y), PRS40C ( 1 2V DC power suppl y) and an MBS 1 000 or DDU250 (desktop ...

  • Bogen PCM2000 - page 25

    CONFIGURA TION 6: EXTENDED P AGING SY STEM This illustration sho ws the wir ing between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described pre viously , the requir ed setup for one-wa y basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the pow er supply PCMPS2. For PCM syste ...

  • Bogen PCM2000 - page 26

    CONFIGURA TION 1 2: DFT 1 20 & T AMB WIRING DIA GRAM - LOOP ST AR T TRUNK, GR OUND ST AR T TRUNK, OR ST A TION LEVEL In this configuration, the telephone output is connected to the Bogen T elephone Access Module model T AMB; the T AMB module is connected to the Bogen Digital Feedback T erminator model DFT 1 20; and the DFT 1 20 is connected to ...

  • Bogen PCM2000 - page 27

    CONFIGURA TION 5: ST A TION LEVEL/CENTREX - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module and answ ers after the first full ring. As soon as it answers, the default timer is started. The defau ...

  • Bogen PCM2000 - page 28

    CONFIGURA TION 1 3: EMERGENCY V OICE ANNOUNCEMENT O VERRIDE V oice Announcement Override is a non-pr ogrammable feature that lets the caller tak e priority ov er all paging functions and make a system- wide emergency voice announcement page to all speak ers. In addition to the PCM modules, this option requir es a Pr oHold (digital announc- er) and ...

  • Bogen PCM2000 - page 29

    CONFIGURA TION 4: GROUND ST AR T TR UNK - 3-ZONE - ONE-W A Y P AGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone system. There ar e two modes of operation f ...

  • Bogen PCM2000 - page 30

    CONFIGURA TION 1 4: DTMF MICROPHONE ZONE P A GING This section will describe the configuration f or the use of a Shure micr ophone Model 885TT with DTMF dialing capabilities and the MODULINK f ive- conductor coil-cord model ALM- 1 . In addition to the PCM2000 system and associated amplifiers, the model numbers and components r equired for this conf ...

  • Bogen PCM2000 - page 31

    CONFIGURA TION 3: LOOP ST AR T TR UNK - 3-ZONE - ONE-W A Y P A GING - SINGLE AMPLIFIER - 25/70V A C SPEAKERS In this configuration, the PCM unit supplies a 48V talk batter y and loop curr ent detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system. There are tw o modes of operation for ...

  • Bogen PCM2000 - page 32

    Each PCMZPM module has three r elay driv er outputs - RD A, RD B, and RD C - one for each speak er zone . When a zone is activated, its rela y driver is shorted to RD COM through an open collector transistor . These drivers can be used to activate external rela ys to pro vide greater po wer ca pacity or to operate external equipment. The pow er sup ...

  • Bogen PCM2000 - page 33

    SECTION II - PROGRAMMING SY STEM PROGRAMMING System programming lets y ou set cer tain PCM options and tone features using the DTMF k eys of a telephone. It also lets you progr am pag- ing zone groups and signaling zone gr oups. All programming is accomplished thr ough the TEL LINE jack on the PCMTIM module regardless of the telephone interface use ...

  • Bogen PCM2000 - page 34

    FEA TURE CODES AND DEF AUL TS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce T one Inhibit 003 Beep 004 Chime 005 Chime Confirmation T one Inhibit 00 1 Inhibit Enable 002 Emergency O/R T one Inhibit 008 Inhibit Enable 009 All-Call Inhibit 0 1 0 Enable 0 11 Enable Dialing Time-out Inhibit 0 1 2 E ...

  • Bogen PCM2000 - page 35

    Clock Set 060 HHMM 00:00 Clock Sync. 067 HHMM (See Note 3 - p . 37) Inhibit 068 Inhibit Enable 069 Time T rigger 1 Zone Group *8 1 Zone Numbers No Zones Inhibit 11 0 Inhibit Enable 111 HHMM (See Note 3 - p . 37) 2-Second T one 11 2 3-Second T one 11 3 3-Second T one 4-Second T one 11 4 5-Second T one 11 5 6-Second T one 11 6 7-Second T one 11 7 8-S ...

  • Bogen PCM2000 - page 36

    Time T rigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second T one 1 62 3-Second T one 1 63 3-Second T one 4-Second T one 1 64 5-Second T one 1 65 6-Second T one 1 66 7-Second T one 1 67 8-Second T one 1 68 Chime 1 69 Time T rigger 7 Zone Group *87 Zone Numbers No Zones Inhibit 1 70 Inhib ...

  • Bogen PCM2000 - page 37

    Zone #’ s S 1 S2 S3 S4 Master 1 - 9 0000 Satellite 1 1 0- 1 8 1 000 2 1 9-27 0 1 00 3 28-36 11 00 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 11 0 7 64-72 111 0 8 73-8 1 000 1 9 82-90 1 00 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICA T ON CONFIGURA TIONS ......................................................................................... ...

  • Bogen PCM2000 - page 38

    PCM2000 Configuration Guide 50 Spring Street, Ramsey , NJ 07446 U.S.A. T el. 20 1 -934-8500 / Fax 20 1 -934-9832/ www .bogen.com ...

Fabbricante Bogen Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoBogen PCM2000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bogen
- manuali per l’uso PCM2000
- schede prodotto Bogen
- opuscoli
- o etichette energetiche Bogen PCM2000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bogen PCM2000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bogen PCM2000, manuali di manutenzione, brevi manuali o manuali utente Bogen PCM2000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bogen PCM2000.

Manuali per l’uso simili

Manuale completo del dispositivo Bogen PCM2000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bogen PCM2000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bogen PCM2000.

Il manuale per l’uso completo Bogen, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bogen PCM2000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bogen PCM2000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bogen PCM2000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bogen PCM2000 - che ci dovrebbe aiutare nei primi passi durante l'uso Bogen PCM2000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bogen PCM2000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bogen PCM2000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bogen PCM2000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bogen PCM2000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bogen PCM2000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)