R www .quadrare.com October 27, 201 1 CASTILE & SANT A FE PELLET INSERT Owner ’ s Manual Installation and Operation CASTILEI-CE-MBK SANT AFEI-CE-MBK Models: DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instruc - tionsincluded. • Leave this manual with party responsible f ...
-
Quadra-Fire CASTILEI-CE-MBK - page 2
Page2 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition of excellence!InchoosingaQuadra-Fire appliance,youhaveour assurance of commitment to quality , dur ...
-
Quadra-Fire CASTILEI-CE-MBK - page 3
R October 27, 201 1 Page3 Castile & Santa Fe CE Insert 7069-101B T ABLE OF CONTENTS Safety Alert Key: • DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury . • W ARNING! Indicatesahazardoussituationwhich,ifnotavoidedcouldre ...
-
Quadra-Fire CASTILEI-CE-MBK - page 4
Page4 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B ...
-
Quadra-Fire CASTILEI-CE-MBK - page 5
R October 27, 201 1 Page5 Castile & Santa Fe CE Insert 7069-101B ...
-
Quadra-Fire CASTILEI-CE-MBK - page 6
Page6 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B A. Appliance Certication B. Glass Specications D. Specications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealerforreplacement? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 7
R October 27, 201 1 Page7 Castile & Santa Fe CE Insert 7069-101B HOT SURF ACES! Glassandothersurfacesarehotduringoperation ANDcooldown. Hot glass will cause burns. • Donottouchglassuntilitiscooled • NEVERallowchildrentotouchglass • Keepchildrenaway ? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 8
Page8 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B A. Fire Safety T o provide reasonable re safety , the following should be givenseriousconsideration: • Install at least one smoke detector and CO monitor on each oorofyourhome. • Loc ...
-
Quadra-Fire CASTILEI-CE-MBK - page 9
R October 27, 201 1 Page9 Castile & Santa Fe CE Insert 7069-101B D. General Operating Information 1. Thermostat Calls For Heat The appliance is like most modern furnaces; when the thermostat callsfor heat,your appliancewill automaticallylight anddeliver heat. When the r ...
-
Quadra-Fire CASTILEI-CE-MBK - page 10
Page10 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B H. Fire Characteristics A properly adjusted re with the heat output control button seton“HIGH”hasashort activeamepatternthatextends outoftherepotapproximately102mm. If the ...
-
Quadra-Fire CASTILEI-CE-MBK - page 11
R October 27, 201 1 Page1 1 Castile & Santa Fe CE Insert 7069-101B J. Ignition Cycles 1. At the beginningof eachignition cycle, itis normalto see some smoke in the rebox. The smoke will stop once therestarts. 2. The convection blower will a ...
-
Quadra-Fire CASTILEI-CE-MBK - page 12
Page12 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 3 Maintaining & Servicing Y our Appliance C. General Maintenance 1. T ypes of Fuel Depending on the type of fuel you are burning will dictate how oftenyouhavetocleanyourrepot. Ifthe fuelyou are? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 13
R October 27, 201 1 Page13 Castile & Santa Fe CE Insert 7069-101B 5. Disposal of Ashes • Frequency: Asneeded • By: Homeowner Ashes should be placed in a metal container with a tight-tting lid. The closed container of ashes should be placedon anon- ...
-
Quadra-Fire CASTILEI-CE-MBK - page 14
Page14 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B The amount of ash buildup in the repot will be a good guide to determine how often you should clean the heat exchangers. W ARNING Heatexchangercleaningrodsmaybewarm tothetouch.? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 15
R October 27, 201 1 Page15 Castile & Santa Fe CE Insert 7069-101B 12. Cleaning Combustion Blower - Requires No Lubrication • Frequency: Y earlyorasneeded • By: QualiedServiceT echnician • T ask: Contact your local dealer 13. Cleaning Convection Blower - Requires No Lubrication • Frequency: ...
-
Quadra-Fire CASTILEI-CE-MBK - page 16
Page16 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B D. High Ash Fuel Content Maintenance • Frequency: Asneeded • By: Homeowner Correct Flame Size, Y ellow/White in Color Correct Figure 16.3 Ash Build Up in Firebox Pellets Back Up In Feed T ube Firepot Overfills T all, Lazy Flame, Orange in Color Incorrect ...
-
Quadra-Fire CASTILEI-CE-MBK - page 17
R October 27, 201 1 Page17 Castile & Santa Fe CE Insert 7069-101B NOTICE: Odors and vapors are released during initial operation due to the curing of high tem - peraturepaint.Openwindowsforaircirculation.Odorsmaybeirritatingtosensitiveindividuals. 4 T r ...
-
Quadra-Fire CASTILEI-CE-MBK - page 18
Page18 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 5 Getting Started Installer ’ s Guide A . Design, Installation & Location Considerations W ARNING! Risk of Fire Damaged parts could impair safe operation. Do NOT install damaged, incomplete or substitute components. 1. Applian ...
-
Quadra-Fire CASTILEI-CE-MBK - page 19
R October 27, 201 1 Page19 Castile & Santa Fe CE Insert 7069-101B B. Thermostat Location The thermostat’s location will have some effect on the appliance’soperation. When the thermostat is located close to the appliance, it may require aslightly highert ...
-
Quadra-Fire CASTILEI-CE-MBK - page 20
Page20 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 6 Dimensions and Clearances A. A ppliance Dimensions Figure 20.3- Front View Figure 20.1 - T op View Figure 20.2 -Side View 819mm 707mm 594mm 203mm 483mm 629mm 249mm 330mm 51mm Overall Size A B MetalSurroundw/CastT rim,STD 1080mm 762mm MetalSurroundw/Cast? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 21
R October 27, 201 1 Page21 Castile & Santa Fe CE Insert 7069-101B Figure 20.4 - T op View A B C D C. Minimum Opening for Masonry and Factory-Built Fireplaces Inches Millimeters A Insertsidetocombustiblesidewall 16 406 B Inserttoptomantel 12 305 C Inserttoptomaximum.2-1/4inch (57mm)facetrim 4 ...
-
Quadra-Fire CASTILEI-CE-MBK - page 22
Page22 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B Do not terminate vent inanyenclosedorsemi-enclosed areasuchasacarport,garage,attic,crawlspace,undera sundeckorporch,narrowwalkwayorcloselyfencedarea, oranylocationthatcanbuild ...
-
Quadra-Fire CASTILEI-CE-MBK - page 23
R October 27, 201 1 Page23 Castile & Santa Fe CE Insert 7069-101B V ent Congurations T oreduce probability ofreverse drafting duringshut-down conditions Hearth & Home T echnologies strongly recom - mends: • Installing the pellet vent with a minimum vertical ...
-
Quadra-Fire CASTILEI-CE-MBK - page 24
Page24 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B E. Chimney and Exhaust Connection 1. Chimney & Connector :Use76mmto102mmdiameter type "L" or "PL" venting system. It can be vented vertically orhorizontally . 2. Residential: Use 24 ...
-
Quadra-Fire CASTILEI-CE-MBK - page 25
R October 27, 201 1 Page25 Castile & Santa Fe CE Insert 7069-101B F. P ellet V enting Charts FireRisk. • Only LISTED venting components may be used. • NOOTHER ventcomponentsmaybe used. Substituteordamagedventcomponentsmay impairsafeoperation. W ARNING The maximum? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 26
Page26 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 8 V enting Systems Figure 28.1 CAUTION Neverdrawoutsidecombustionairfrom: • W all,oororceilingcavity • Enclosedspacesuchasanatticorgarage NOTE: • Illustrationsreecttypicalinstallationsandar ...
-
Quadra-Fire CASTILEI-CE-MBK - page 27
R October 27, 201 1 Page27 Castile & Santa Fe CE Insert 7069-101B B. Full Reline With V ertical Outside Air Figure 29.1 Outside Air T ermination at Chimney T op 12” (305mm) min. below 12” (305mm) min. above NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as mineral wool or ceramic. ...
-
Quadra-Fire CASTILEI-CE-MBK - page 28
Page28 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 9 Appliance Set-Up A. Leveling System B. Outside Air Kit Instructions Parts Included in Kit: 1pieceof51mmx914mmex hose,2hoseclamps,1collarassembly ,1terminationcap assembly ,1trimring,fastenersand ...
-
Quadra-Fire CASTILEI-CE-MBK - page 29
R October 27, 201 1 Page29 Castile & Santa Fe CE Insert 7069-101B C. Door Handle Removal 1. Opentheouterdoor . 2. Unlatchandopenthereboxdoor . 3. Continue to turn handle until it is free from the rebox door . D. Door Removal 1. Opentheouterdoor . 2. ...
-
Quadra-Fire CASTILEI-CE-MBK - page 30
Page30 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B Figure 32.2 1 2 3 4 5 6 7 8 F . Hearth Support For Standard Surround Only Figure 33.1 - Assembled View Item Description 1 Front,76mm 2 Front,127mm 3 CastRing,T op&Bottom,Interchangeable 4 Side,127mm 5 Side,76mm 6 PanelExtension,127mm 7 Pane ...
-
Quadra-Fire CASTILEI-CE-MBK - page 31
R October 27, 201 1 Page31 Castile & Santa Fe CE Insert 7069-101B Base Plate Only Installation Parts Needed :(1)castring(2)basezeroclearancepanel extensions.Discardbalanceofparts. T ools Needed: Phillipsheadscrewdriver 1. Attachbasezeroclearancepanelextensionstocast? ...
-
Quadra-Fire CASTILEI-CE-MBK - page 32
Page32 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B H. Surround and Cast T rim Set (CASTILE INSERT) I ncluded in Surround Kit: (2)sidesurrounds,leftand right;(1)surroundtop;(1)fastenerpackage. Included in Cast T rim Kit: (2)casttrimlegs,leftandright;(1) ca ...
-
Quadra-Fire CASTILEI-CE-MBK - page 33
R October 27, 201 1 Page33 Castile & Santa Fe CE Insert 7069-101B I. Panel and T rim Set (SANT A FE INSERT) 1. Laypanel topand legs facedown onprotective cov - eringtopreventscratching. 1. Attachthe panellegs tothe toppanel usinga Phillips head screwdriver . ...
-
Quadra-Fire CASTILEI-CE-MBK - page 34
Page34 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 1. Opendoortoexposetherebox. 2. Install the left log rst and then the right log. Figure 37.1 3. Lean the logs against the cast iron brick in the back of therebox. 4. Pus ...
-
Quadra-Fire CASTILEI-CE-MBK - page 35
R October 27, 201 1 Page35 Castile & Santa Fe CE Insert 7069-101B 1 . A 12 volt ACthermostat is required to operate this pellet appliance. Y ou may use the included wall mount thermo - stator purchase an optional programmablethermostat orremotecont ...
-
Quadra-Fire CASTILEI-CE-MBK - page 36
Page36 R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI CORPORA TION www .quadrare.com CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer visit our website at www .quadrare.com This product may be covere ...
¿Tienes una pregunta acerca de Quadra-Fire CASTILEI-CE-MBK?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Quadra-Fire CASTILEI-CE-MBK, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Quadra-Fire CASTILEI-CE-MBK probablemente compartirá una forma de solucionarlo.