    1 61220010L2-5, Issue 3 61220010L2-5C Section 61220010L2-5C Issue 3, April 2001 CLEI # NCT1TX2B _ _ T200 IDSL OCU-R Remote T ermination Unit Installation and Maintenance Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 1. GENERAL This practice ...

  • ADTRAN T200 IDSL - page 2

    2 61220010L2-5, Issue 3 61220010L2-5C 2. OPTIONS Options and rate are selected with the front panel DIP switches as shown in Figure 1 and listed in Table 1. Customer Interface Transmit Line Build Out When -10 dB (SW1-1) is ON, the IDSL OCU-R transmits a -10 dB AMI signal across the 4-wire customer interface toward the CSU/DSU. When OFF is selected ...

  • ADTRAN T200 IDSL - page 3

    3 61220010L2-5, Issue 3 61220010L2-5C C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Quality Monitor (QM) When QM (SW1-2) is ON, the IDSL OCU-R monitors the customer interface for errors. If excessive errors are detected the unit blocks customer data transmission and sends Abnormal Station ...

  • ADTRAN T200 IDSL - page 4

    4 61220010L2-5, Issue 3 61220010L2-5C Wiring The ADTRAN IDSL OCU-R may be mounted in any standard T400/T200 housing, or the following ADTRAN T400/T200 housings: CAUTION On span-powered units, ensure ground continuity exists between the unit, the housing, and a known approved ground source. Span Power Applications • Single Mount Housing P/N 121200 ...

  • ADTRAN T200 IDSL - page 5

    5 61220010L2-5, Issue 3 61220010L2-5C LED Indication The IDSL OCU-R front panel LEDs display the operating status. The LEDs are described in Table 5 . 4. TESTING Loopback Testing Loopback tests can be performed from the Central Office (CO) to verify proper loop and IDSL OCU-R operation. The IDSL OCU-R provides a network loopback in response to an O ...

  • ADTRAN T200 IDSL - page 6

    6 61220010L2-5, Issue 3 61220010L2-5C IDSL/DDS Trouble Code The IDSL/DDS system provides a quick diagnosis in the case of a circuit condition where continuity is broken when the IDSL/DDS circuit uses ADTRAN U- BR1TEs with DDS Loopback capability in the central office or remote terminal. The trouble code type received by a tester determines whether ...

  • ADTRAN T200 IDSL - page 7

    7 61220010L2-5, Issue 3 61220010L2-5C All existing latching loopbacks can also be disabled by pressing the TEST or LBK pushbutton on the U-BR1TE or remote unit, respectively. NOTE The remote end test feature is only supported when the upstream U-BR1TE is an ADTRAN D4 or Series 5 U-BR1TE with DDS Loopback capability. Other U-BR1TEs will ignore the l ...

  • ADTRAN T200 IDSL - page 8

    8 61220010L2-5, Issue 3 61220010L2-5C Table 8. Definition of Screen Abbreviations Abbreviation and Definition ES – Error ed Seconds: A count of the number of seconds in which at least one code violation was detected on a  digital circuit.  • IDSL Interface ....Second in which a CRC error occurs.  • Customer DDS Interface. ...

  • ADTRAN T200 IDSL - page 9

    9 61220010L2-5, Issue 3 61220010L2-5C To conduct a terminal session, connect a VT100 or compatible test set to the OCU-R via the front panel DB-9 connector, then press the space bar three times to initiate the session. The Main Menu will appear, as illustrated in Figure 9 . The Main Menu provides access to detailed performance and configuration inf ...

  • ADTRAN T200 IDSL - page 10

    10 61220010L2-5, Issue 3 61220010L2-5C Figure 11 shows the System Status screen. Figure 12 shows Detailed Status for both network and customer loops. Figure 11. System Status Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:31:30 System Status Screen Channel Bank DDS Loop ____________ ____________ | UBR1TE | | OCU-R | | | | |------> | | | | | | | | ...

  • ADTRAN T200 IDSL - page 11

    11 61220010L2-5, Issue 3 61220010L2-5C Figure 13 shows the Loopbacks display, allowing loopback testing to be initiated or terminated while graphically displaying the testing status of the IDSL system. Latching Loopback Timeout When latching loopback timeout is enabled, latching loopbacks will drop out after 120 minutes returning the system to norm ...

  • ADTRAN T200 IDSL - page 12

    12 61220010L2-5, Issue 3 61220010L2-5C Clearing PM and Event Log Registers Press “5” at the Performance Monitoring screen (Figure 14) to advance to the Warning screen (not shown). At the Warning screen the user will be prompted to clear registers; “Y” for Yes or “N” for No. Figure 15. U-BR1TE 15-Minute Performance Monitoring Screen Inte ...

  • ADTRAN T200 IDSL - page 13

    13 61220010L2-5, Issue 3 61220010L2-5C Figure 17. Frame Relay 15-Minute Performance Monitoring Screen Figure 18. Frame Relay 24-Hour Performance Monitoring Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:37:18 Frame Relay 15-Minute Registers IDSL INTERFACE DDS LOOP -INV--FECN--BECN---LMI--%UT -INV--FECN--BECN---LMI--%UT 00000 00000 00000 00000 000 000 ...

  • ADTRAN T200 IDSL - page 14

    14 61220010L2-5, Issue 3 61220010L2-5C The Event Log, shown in Figure 19 , loads and time- stamps IDSL circuit performance anomalies and threshold violations. This screen is a very useful aid in troubleshooting a chronic circuit. It monitors DDS sync loss, DDS open loop, IDSL OCU-R margin, IDSL sync loss, and power-up events. IDSL loop signal-to-no ...

  • ADTRAN T200 IDSL - page 15

    15 61220010L2-5, Issue 3 61220010L2-5C The Set Date and Time screen, Figure 21 , may be used to set the IDSL OCU-R date and time. Once the date and time are configured the performance registers date and time update accordingly. The ADTRAN Information screen, Figure 22 , displays part number, serial number, CLEI code, and unit revision for the IDSL ...

  • ADTRAN T200 IDSL - page 16

    16 61220010L2-5, Issue 3 61220010L2-5C 6. REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Remote access to provisioning and status information is accomplished using ADTRAN Digital System 6 Message protocol, defined in Control and Diagnostic Procedures Practice, Section 6032991-6. Digital System 6 is supported by the TPI 108/109 and 105 portabl ...

  • ADTRAN T200 IDSL - page 17

    17 61220010L2-5, Issue 3 61220010L2-5C For service, CAPS requests, or further information, contact one of the following numbers: ADTRAN Sales Pricing/Availability (800) 827-0807 ADTRAN Technical Support Pre-sales Applications/Post-sales Technical Assistance (800) 726-8663 Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST Emergency hours: 7 days/we ...

  • ADTRAN T200 IDSL - page 18

    18 61220010L2-5, Issue 3 61220010L2-5C ...

Fabricante ADTRAN Categoría Network Card

Los documentos del dispositivo ADTRAN T200 IDSL que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ADTRAN
- manuales de instrucciones T200 IDSL
- hojas de producto ADTRAN
- folletos informativos
- o etiquetas energéticas ADTRAN T200 IDSL
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ADTRAN T200 IDSL.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ADTRAN T200 IDSL, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ADTRAN T200 IDSL. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ADTRAN T200 IDSL.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ADTRAN T200 IDSL, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ADTRAN T200 IDSL. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ADTRAN T200 IDSL.

El manual de instrucciones completo de ADTRAN debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ADTRAN T200 IDSL - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ADTRAN T200 IDSL, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ADTRAN T200 IDSL que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ADTRAN T200 IDSL - que deben facilitarnos los primeros pasos durante el uso de ADTRAN T200 IDSL
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ADTRAN T200 IDSL
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ADTRAN T200 IDSL en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ADTRAN T200 IDSL?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ADTRAN T200 IDSL, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ADTRAN T200 IDSL probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)