    1 61220010L2-5, Issue 3 61220010L2-5C Section 61220010L2-5C Issue 3, April 2001 CLEI # NCT1TX2B _ _ T200 IDSL OCU-R Remote T ermination Unit Installation and Maintenance Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 1. GENERAL This practice ...

  • ADTRAN T200 IDSL - page 2

    2 61220010L2-5, Issue 3 61220010L2-5C 2. OPTIONS Options and rate are selected with the front panel DIP switches as shown in Figure 1 and listed in Table 1. Customer Interface Transmit Line Build Out When -10 dB (SW1-1) is ON, the IDSL OCU-R transmits a -10 dB AMI signal across the 4-wire customer interface toward the CSU/DSU. When OFF is selected ...

  • ADTRAN T200 IDSL - page 3

    3 61220010L2-5, Issue 3 61220010L2-5C C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Quality Monitor (QM) When QM (SW1-2) is ON, the IDSL OCU-R monitors the customer interface for errors. If excessive errors are detected the unit blocks customer data transmission and sends Abnormal Station ...

  • ADTRAN T200 IDSL - page 4

    4 61220010L2-5, Issue 3 61220010L2-5C Wiring The ADTRAN IDSL OCU-R may be mounted in any standard T400/T200 housing, or the following ADTRAN T400/T200 housings: CAUTION On span-powered units, ensure ground continuity exists between the unit, the housing, and a known approved ground source. Span Power Applications • Single Mount Housing P/N 121200 ...

  • ADTRAN T200 IDSL - page 5

    5 61220010L2-5, Issue 3 61220010L2-5C LED Indication The IDSL OCU-R front panel LEDs display the operating status. The LEDs are described in Table 5 . 4. TESTING Loopback Testing Loopback tests can be performed from the Central Office (CO) to verify proper loop and IDSL OCU-R operation. The IDSL OCU-R provides a network loopback in response to an O ...

  • ADTRAN T200 IDSL - page 6

    6 61220010L2-5, Issue 3 61220010L2-5C IDSL/DDS Trouble Code The IDSL/DDS system provides a quick diagnosis in the case of a circuit condition where continuity is broken when the IDSL/DDS circuit uses ADTRAN U- BR1TEs with DDS Loopback capability in the central office or remote terminal. The trouble code type received by a tester determines whether ...

  • ADTRAN T200 IDSL - page 7

    7 61220010L2-5, Issue 3 61220010L2-5C All existing latching loopbacks can also be disabled by pressing the TEST or LBK pushbutton on the U-BR1TE or remote unit, respectively. NOTE The remote end test feature is only supported when the upstream U-BR1TE is an ADTRAN D4 or Series 5 U-BR1TE with DDS Loopback capability. Other U-BR1TEs will ignore the l ...

  • ADTRAN T200 IDSL - page 8

    8 61220010L2-5, Issue 3 61220010L2-5C Table 8. Definition of Screen Abbreviations Abbreviation and Definition ES – Error ed Seconds: A count of the number of seconds in which at least one code violation was detected on a  digital circuit.  • IDSL Interface ....Second in which a CRC error occurs.  • Customer DDS Interface. ...

  • ADTRAN T200 IDSL - page 9

    9 61220010L2-5, Issue 3 61220010L2-5C To conduct a terminal session, connect a VT100 or compatible test set to the OCU-R via the front panel DB-9 connector, then press the space bar three times to initiate the session. The Main Menu will appear, as illustrated in Figure 9 . The Main Menu provides access to detailed performance and configuration inf ...

  • ADTRAN T200 IDSL - page 10

    10 61220010L2-5, Issue 3 61220010L2-5C Figure 11 shows the System Status screen. Figure 12 shows Detailed Status for both network and customer loops. Figure 11. System Status Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:31:30 System Status Screen Channel Bank DDS Loop ____________ ____________ | UBR1TE | | OCU-R | | | | |------> | | | | | | | | ...

  • ADTRAN T200 IDSL - page 11

    11 61220010L2-5, Issue 3 61220010L2-5C Figure 13 shows the Loopbacks display, allowing loopback testing to be initiated or terminated while graphically displaying the testing status of the IDSL system. Latching Loopback Timeout When latching loopback timeout is enabled, latching loopbacks will drop out after 120 minutes returning the system to norm ...

  • ADTRAN T200 IDSL - page 12

    12 61220010L2-5, Issue 3 61220010L2-5C Clearing PM and Event Log Registers Press “5” at the Performance Monitoring screen (Figure 14) to advance to the Warning screen (not shown). At the Warning screen the user will be prompted to clear registers; “Y” for Yes or “N” for No. Figure 15. U-BR1TE 15-Minute Performance Monitoring Screen Inte ...

  • ADTRAN T200 IDSL - page 13

    13 61220010L2-5, Issue 3 61220010L2-5C Figure 17. Frame Relay 15-Minute Performance Monitoring Screen Figure 18. Frame Relay 24-Hour Performance Monitoring Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:37:18 Frame Relay 15-Minute Registers IDSL INTERFACE DDS LOOP -INV--FECN--BECN---LMI--%UT -INV--FECN--BECN---LMI--%UT 00000 00000 00000 00000 000 000 ...

  • ADTRAN T200 IDSL - page 14

    14 61220010L2-5, Issue 3 61220010L2-5C The Event Log, shown in Figure 19 , loads and time- stamps IDSL circuit performance anomalies and threshold violations. This screen is a very useful aid in troubleshooting a chronic circuit. It monitors DDS sync loss, DDS open loop, IDSL OCU-R margin, IDSL sync loss, and power-up events. IDSL loop signal-to-no ...

  • ADTRAN T200 IDSL - page 15

    15 61220010L2-5, Issue 3 61220010L2-5C The Set Date and Time screen, Figure 21 , may be used to set the IDSL OCU-R date and time. Once the date and time are configured the performance registers date and time update accordingly. The ADTRAN Information screen, Figure 22 , displays part number, serial number, CLEI code, and unit revision for the IDSL ...

  • ADTRAN T200 IDSL - page 16

    16 61220010L2-5, Issue 3 61220010L2-5C 6. REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Remote access to provisioning and status information is accomplished using ADTRAN Digital System 6 Message protocol, defined in Control and Diagnostic Procedures Practice, Section 6032991-6. Digital System 6 is supported by the TPI 108/109 and 105 portabl ...

  • ADTRAN T200 IDSL - page 17

    17 61220010L2-5, Issue 3 61220010L2-5C For service, CAPS requests, or further information, contact one of the following numbers: ADTRAN Sales Pricing/Availability (800) 827-0807 ADTRAN Technical Support Pre-sales Applications/Post-sales Technical Assistance (800) 726-8663 Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST Emergency hours: 7 days/we ...

  • ADTRAN T200 IDSL - page 18

    18 61220010L2-5, Issue 3 61220010L2-5C ...

メーカー ADTRAN カテゴリー Network Card

ADTRAN T200 IDSLのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- T200 IDSLの取扱説明書
- ADTRANの製品カード
- パンフレット
- またはADTRAN T200 IDSLの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ADTRAN T200 IDSLの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ADTRAN T200 IDSLの取り付け説明書、サービスマニュアル、簡易説明書、またはADTRAN T200 IDSLのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ADTRAN T200 IDSLの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ADTRAN T200 IDSLデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがADTRAN T200 IDSLを使用するのを助ける技術的文書のことです。説明書は通常、全てのADTRAN T200 IDSLユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ADTRANの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ADTRAN T200 IDSLの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははADTRAN T200 IDSLの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ADTRAN T200 IDSLに関してこのドキュメントで見つけることができる全てのヒントの目次
3. ADTRAN T200 IDSLデバイスの基本機能を使うにあたってのヒント。 ADTRAN T200 IDSLのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ADTRAN T200 IDSLに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるADTRAN T200 IDSLのメーカー/サービスへの連絡先に関する情報。

ADTRAN T200 IDSLについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもADTRAN T200 IDSLの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがADTRAN T200 IDSLで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)