Summary
  • Omega Engineering FLR6000 series - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide FLR5000, 6000, 7000, 8000, and 9000 SERIES Flow T ransmitter Shop online at MADE IN ...

  • Omega Engineering FLR6000 series - page 2

    OMEGAnet ® On -L in e S er vi ce Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon ...

  • Omega Engineering FLR6000 series - page 3

    I. INTRODUCTION The FLR Flow T ransmitter is a state-of-the-art, micro- processor based variable area flow meter . It combines the rugged proven technology of a piston-type, variable area flow meter with solid state circuitry including: • Non-contact sensor electronics • Electronic signal conditioning circuit • Digital flow rate and total ind ...

  • Omega Engineering FLR6000 series - page 4

    II. SPECIFICA TIONS Enclosure Rating • NEMA 12 & 13 (equivalent to IP 52/54) Operating T emperature • Fluid: -20 ° to 240 ° F (-29 ° to 1 16 ° C) • Ambient: -20 ° to 158 ° F (-29 ° to 70 ° C) Environment al • Humidity: 0–90 % non-condensing Pressure (Aluminum / Brass Operating) • Liquids ( 1 / 4 " to 1- 1 / 2 "): 3 ...

  • Omega Engineering FLR6000 series - page 5

    T able 1 - Dimensions III. INST ALLA TION This unit should be inst alled and serviced by technically qualified personnel trained in maint aining industrial class flow instrumentation and processing equipment. FLR Flow T ransmitter Inst allation & Programming Instructions Page 3 AB C D E F G H I J K Nominal Length Length Length Wid th Wid th Wid ...

  • Omega Engineering FLR6000 series - page 6

    Inst allation Recommendations The transmitter is a simple device to install. However , the following measures are recommended for reliable, trouble-free operation: DO - Align pipe accurately . Piping should be accurate- ly aligned and of correct length. The high pressure body of the transmitter can withstand shock and flow/pressure pulsation. Howev ...

  • Omega Engineering FLR6000 series - page 7

    Schematics The transmitter can be wired in various configurations to allow interface with many different types of dat a col- lection and control instrumentation. Schematics 1 & 2 represent typical wiring for a target powered by either AC power or DC supply . Schematics 3 & 4 will be utilized when the flow trans- mitter is operated with loop ...

  • Omega Engineering FLR6000 series - page 8

    Inst alling the T ransmitter 1. Disconnect electrical power from the target sys- tem before making or changing any transmitter connections. 2. Use 0.05A fast acting fuse if non-current limited power sources are utilized. 3. T erminate cable shield connection at either DC ground or Earth ground. 4. Mount the transmitter so fluid is traveling in the ...

  • Omega Engineering FLR6000 series - page 9

    ENTER - The current tot al can be manually stored in the monitor's flash memory . Press and hold the ENTER key for 2 seconds. The display will respond with a flashing T OT ALSVD and then will return to RUN mode. RESET TOT AL - T o reset the monitor total display , press the MENU and ENTER keys simultaneously until TOT ALRST starts to flash. Th ...

  • Omega Engineering FLR6000 series - page 10

    Programming Procedures The FLR T ransmitter allows two basic sets of program- ming procedures: list item selection and entering numeric values. List Item Selection Procedure Note: If you are already in PROGRAM mode and the selection to be viewed or changed is already displayed, proceed to step 3 below. If you are in PROGRAM mode and the selection t ...

  • Omega Engineering FLR6000 series - page 11

    Programming Flow Chart The programming flow chart on pages 10 and 1 1 will aid understanding of the menu structure of the FLR Flow T ransmitter . It will also help with understanding the available configuration selections. Programming Descriptions Display Mode The meter can display RA TE (flow rate) or T OT AL (total accumulated flow) or alternate ...

  • Omega Engineering FLR6000 series - page 12

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 10 ...

  • Omega Engineering FLR6000 series - page 13

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 11 ...

  • Omega Engineering FLR6000 series - page 14

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 12 Zero Capture The zero position of the meter cone must be set when installing the meter . T o capture the zero calibration position, press ENTER at the ZERO CAP prompt. NO will display . Press either arrow key to change to YES, then press ENTER to capture zero. Meter T ype Th ...

  • Omega Engineering FLR6000 series - page 15

    Output Mode The FLR Flow T ransmitter offers three analog output modes: • 4–20 mA Output Signal • 0–5 V olts DC Output Signal • 0–10 V olts DC Output Signal The output mode selected is determined by the type of peripheral device being connected to the FLR Flow T ransmitter . The displayed name is OUT MODE and is viewed or changed using ...

  • Omega Engineering FLR6000 series - page 16

    Password Password protection prevents unauthorized users from changing programming information. Initially the pass- word is set to all zeros. Its displayed name is P ASSWORD and is viewed or changed using the Numeric V alue Entry Procedure found on page 8. Restore Defaults This feature allows you to restore factory calibration data. Its displayed n ...

  • Omega Engineering FLR6000 series - page 17

    Inspection 1. Frequent inspection should be made. The envi- ronment and frequency of use should determine a schedule for maintenance checks. It is recom- mended that it should be at least once a year . 2. Perform visual, electrical, and mechanical checks on all components on a regular basis. 3. Visually check for undue heating evidence such as disc ...

  • Omega Engineering FLR6000 series - page 18

    Application Information – Pneumatic NOTE: Pressure and temperature readings must be taken at the flow transmitter inlet to ensure accurate correction factors. The pneumatic flow transmitter is calibrated for air in standard cubic feet per minute (scfm) at 1.0 s.g. (70 ° F @ 100 psi), and liters per second (lps) at 1.0 s.g. (21 ° C @ 6.9 bar). F ...

  • Omega Engineering FLR6000 series - page 19

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 17 Water Based Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5 4-4 3-30 2-20 FL ...

  • Omega Engineering FLR6000 series - page 20

    FLR Flow T ransmitter Inst allation & Programming Instructions Water FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5-5.0 0.2-2.0 1-10 5-50 4-40 3-30 2-20 ...

  • Omega Engineering FLR6000 series - page 21

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 19 Petroleum Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 .05-.50 .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4"/ 1" 5-50 4-40 3-30 2-20 0 0 ...

  • Omega Engineering FLR6000 series - page 22

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 20 Phosphate Ester FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 0.0 0 2 4 6 0.5 .05-.5O .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0 1 2 2.5 0 2 4 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 1-1/4" ...

  • Omega Engineering FLR6000 series - page 23

    FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , SCFM I S P , P O R D E R U S S E R P 3/4"/1" 15-150 10-100 5-25 5-50 25-250 FLO W , SCFM 1-1/4"/1 - 1/2" 20-200 40-400 60-600 80-800 100-1000 I S P , P O R D E R U S S E R P FLR ...

  • Omega Engineering FLR6000 series - page 24

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 22 Air / Compressed Gases FLO W , SCFM D I S P , L A I T N E R E F F I D E R U S S E R P 100-1400 200-2200 3" FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 1-10 0.5-5 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , ...

  • Omega Engineering FLR6000 series - page 25

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 23 ...

  • Omega Engineering FLR6000 series - page 26

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 24 ...

  • Omega Engineering FLR6000 series - page 27

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega Engineering FLR6000 series - page 28

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com M4183/0405 TEMPERA TURE 䡺 ⻬ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ W ire: Thermocouple, R TD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Co ...

Fabricante Omega Engineering Categoría Marine Sanitation System

Los documentos del dispositivo Omega Engineering FLR6000 series que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega Engineering
- manuales de instrucciones FLR6000 series
- hojas de producto Omega Engineering
- folletos informativos
- o etiquetas energéticas Omega Engineering FLR6000 series
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega Engineering FLR6000 series.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega Engineering FLR6000 series, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega Engineering FLR6000 series. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega Engineering FLR6000 series.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega Engineering FLR6000 series, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega Engineering FLR6000 series. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega Engineering FLR6000 series.

El manual de instrucciones completo de Omega Engineering debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega Engineering FLR6000 series - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega Engineering FLR6000 series, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega Engineering FLR6000 series que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega Engineering FLR6000 series - que deben facilitarnos los primeros pasos durante el uso de Omega Engineering FLR6000 series
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega Engineering FLR6000 series
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega Engineering FLR6000 series en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega Engineering FLR6000 series?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega Engineering FLR6000 series, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega Engineering FLR6000 series probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)