Manuel d’utilisation Omega Engineering FLR6000 series

28 pages 1.39 mb
Télécharger

Aller à la page of 28

Summary
  • Omega Engineering FLR6000 series - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide FLR5000, 6000, 7000, 8000, and 9000 SERIES Flow T ransmitter Shop online at MADE IN ...

  • Omega Engineering FLR6000 series - page 2

    OMEGAnet ® On -L in e S er vi ce Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon ...

  • Omega Engineering FLR6000 series - page 3

    I. INTRODUCTION The FLR Flow T ransmitter is a state-of-the-art, micro- processor based variable area flow meter . It combines the rugged proven technology of a piston-type, variable area flow meter with solid state circuitry including: • Non-contact sensor electronics • Electronic signal conditioning circuit • Digital flow rate and total ind ...

  • Omega Engineering FLR6000 series - page 4

    II. SPECIFICA TIONS Enclosure Rating • NEMA 12 & 13 (equivalent to IP 52/54) Operating T emperature • Fluid: -20 ° to 240 ° F (-29 ° to 1 16 ° C) • Ambient: -20 ° to 158 ° F (-29 ° to 70 ° C) Environment al • Humidity: 0–90 % non-condensing Pressure (Aluminum / Brass Operating) • Liquids ( 1 / 4 " to 1- 1 / 2 "): 3 ...

  • Omega Engineering FLR6000 series - page 5

    T able 1 - Dimensions III. INST ALLA TION This unit should be inst alled and serviced by technically qualified personnel trained in maint aining industrial class flow instrumentation and processing equipment. FLR Flow T ransmitter Inst allation & Programming Instructions Page 3 AB C D E F G H I J K Nominal Length Length Length Wid th Wid th Wid ...

  • Omega Engineering FLR6000 series - page 6

    Inst allation Recommendations The transmitter is a simple device to install. However , the following measures are recommended for reliable, trouble-free operation: DO - Align pipe accurately . Piping should be accurate- ly aligned and of correct length. The high pressure body of the transmitter can withstand shock and flow/pressure pulsation. Howev ...

  • Omega Engineering FLR6000 series - page 7

    Schematics The transmitter can be wired in various configurations to allow interface with many different types of dat a col- lection and control instrumentation. Schematics 1 & 2 represent typical wiring for a target powered by either AC power or DC supply . Schematics 3 & 4 will be utilized when the flow trans- mitter is operated with loop ...

  • Omega Engineering FLR6000 series - page 8

    Inst alling the T ransmitter 1. Disconnect electrical power from the target sys- tem before making or changing any transmitter connections. 2. Use 0.05A fast acting fuse if non-current limited power sources are utilized. 3. T erminate cable shield connection at either DC ground or Earth ground. 4. Mount the transmitter so fluid is traveling in the ...

  • Omega Engineering FLR6000 series - page 9

    ENTER - The current tot al can be manually stored in the monitor's flash memory . Press and hold the ENTER key for 2 seconds. The display will respond with a flashing T OT ALSVD and then will return to RUN mode. RESET TOT AL - T o reset the monitor total display , press the MENU and ENTER keys simultaneously until TOT ALRST starts to flash. Th ...

  • Omega Engineering FLR6000 series - page 10

    Programming Procedures The FLR T ransmitter allows two basic sets of program- ming procedures: list item selection and entering numeric values. List Item Selection Procedure Note: If you are already in PROGRAM mode and the selection to be viewed or changed is already displayed, proceed to step 3 below. If you are in PROGRAM mode and the selection t ...

  • Omega Engineering FLR6000 series - page 11

    Programming Flow Chart The programming flow chart on pages 10 and 1 1 will aid understanding of the menu structure of the FLR Flow T ransmitter . It will also help with understanding the available configuration selections. Programming Descriptions Display Mode The meter can display RA TE (flow rate) or T OT AL (total accumulated flow) or alternate ...

  • Omega Engineering FLR6000 series - page 12

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 10 ...

  • Omega Engineering FLR6000 series - page 13

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 11 ...

  • Omega Engineering FLR6000 series - page 14

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 12 Zero Capture The zero position of the meter cone must be set when installing the meter . T o capture the zero calibration position, press ENTER at the ZERO CAP prompt. NO will display . Press either arrow key to change to YES, then press ENTER to capture zero. Meter T ype Th ...

  • Omega Engineering FLR6000 series - page 15

    Output Mode The FLR Flow T ransmitter offers three analog output modes: • 4–20 mA Output Signal • 0–5 V olts DC Output Signal • 0–10 V olts DC Output Signal The output mode selected is determined by the type of peripheral device being connected to the FLR Flow T ransmitter . The displayed name is OUT MODE and is viewed or changed using ...

  • Omega Engineering FLR6000 series - page 16

    Password Password protection prevents unauthorized users from changing programming information. Initially the pass- word is set to all zeros. Its displayed name is P ASSWORD and is viewed or changed using the Numeric V alue Entry Procedure found on page 8. Restore Defaults This feature allows you to restore factory calibration data. Its displayed n ...

  • Omega Engineering FLR6000 series - page 17

    Inspection 1. Frequent inspection should be made. The envi- ronment and frequency of use should determine a schedule for maintenance checks. It is recom- mended that it should be at least once a year . 2. Perform visual, electrical, and mechanical checks on all components on a regular basis. 3. Visually check for undue heating evidence such as disc ...

  • Omega Engineering FLR6000 series - page 18

    Application Information – Pneumatic NOTE: Pressure and temperature readings must be taken at the flow transmitter inlet to ensure accurate correction factors. The pneumatic flow transmitter is calibrated for air in standard cubic feet per minute (scfm) at 1.0 s.g. (70 ° F @ 100 psi), and liters per second (lps) at 1.0 s.g. (21 ° C @ 6.9 bar). F ...

  • Omega Engineering FLR6000 series - page 19

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 17 Water Based Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5 4-4 3-30 2-20 FL ...

  • Omega Engineering FLR6000 series - page 20

    FLR Flow T ransmitter Inst allation & Programming Instructions Water FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5-5.0 0.2-2.0 1-10 5-50 4-40 3-30 2-20 ...

  • Omega Engineering FLR6000 series - page 21

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 19 Petroleum Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 .05-.50 .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4"/ 1" 5-50 4-40 3-30 2-20 0 0 ...

  • Omega Engineering FLR6000 series - page 22

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 20 Phosphate Ester FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 0.0 0 2 4 6 0.5 .05-.5O .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0 1 2 2.5 0 2 4 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 1-1/4" ...

  • Omega Engineering FLR6000 series - page 23

    FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , SCFM I S P , P O R D E R U S S E R P 3/4"/1" 15-150 10-100 5-25 5-50 25-250 FLO W , SCFM 1-1/4"/1 - 1/2" 20-200 40-400 60-600 80-800 100-1000 I S P , P O R D E R U S S E R P FLR ...

  • Omega Engineering FLR6000 series - page 24

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 22 Air / Compressed Gases FLO W , SCFM D I S P , L A I T N E R E F F I D E R U S S E R P 100-1400 200-2200 3" FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 1-10 0.5-5 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , ...

  • Omega Engineering FLR6000 series - page 25

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 23 ...

  • Omega Engineering FLR6000 series - page 26

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 24 ...

  • Omega Engineering FLR6000 series - page 27

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega Engineering FLR6000 series - page 28

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com M4183/0405 TEMPERA TURE 䡺 ⻬ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ W ire: Thermocouple, R TD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Co ...

Fabricant Omega Engineering Catégorie Marine Sanitation System

Les documents que nous recevons du fabricant de l'appareilOmega Engineering FLR6000 series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Engineering
- manuels d’utilisations FLR6000 series
- fiches produit Omega Engineering
- dépliants
- ou étiquettes-énergie Omega Engineering FLR6000 series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Engineering FLR6000 series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Engineering FLR6000 series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Engineering FLR6000 series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Engineering FLR6000 series.

Manuel d’utilisation complet de l’appareil Omega Engineering FLR6000 series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Engineering FLR6000 series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Engineering FLR6000 series.

Le manuel d’utilisation complet Omega Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Engineering FLR6000 series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Engineering FLR6000 series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Engineering FLR6000 series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Engineering FLR6000 series - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Engineering FLR6000 series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Engineering FLR6000 series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Engineering FLR6000 series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Engineering FLR6000 series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Engineering FLR6000 series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Engineering FLR6000 series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)