Manuale per l’uso Omega Engineering FLR6000 series

28 pagine 1.39 mb
Scarica

Vai alla pagina of 28

Summary
  • Omega Engineering FLR6000 series - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide FLR5000, 6000, 7000, 8000, and 9000 SERIES Flow T ransmitter Shop online at MADE IN ...

  • Omega Engineering FLR6000 series - page 2

    OMEGAnet ® On -L in e S er vi ce Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon ...

  • Omega Engineering FLR6000 series - page 3

    I. INTRODUCTION The FLR Flow T ransmitter is a state-of-the-art, micro- processor based variable area flow meter . It combines the rugged proven technology of a piston-type, variable area flow meter with solid state circuitry including: • Non-contact sensor electronics • Electronic signal conditioning circuit • Digital flow rate and total ind ...

  • Omega Engineering FLR6000 series - page 4

    II. SPECIFICA TIONS Enclosure Rating • NEMA 12 & 13 (equivalent to IP 52/54) Operating T emperature • Fluid: -20 ° to 240 ° F (-29 ° to 1 16 ° C) • Ambient: -20 ° to 158 ° F (-29 ° to 70 ° C) Environment al • Humidity: 0–90 % non-condensing Pressure (Aluminum / Brass Operating) • Liquids ( 1 / 4 " to 1- 1 / 2 "): 3 ...

  • Omega Engineering FLR6000 series - page 5

    T able 1 - Dimensions III. INST ALLA TION This unit should be inst alled and serviced by technically qualified personnel trained in maint aining industrial class flow instrumentation and processing equipment. FLR Flow T ransmitter Inst allation & Programming Instructions Page 3 AB C D E F G H I J K Nominal Length Length Length Wid th Wid th Wid ...

  • Omega Engineering FLR6000 series - page 6

    Inst allation Recommendations The transmitter is a simple device to install. However , the following measures are recommended for reliable, trouble-free operation: DO - Align pipe accurately . Piping should be accurate- ly aligned and of correct length. The high pressure body of the transmitter can withstand shock and flow/pressure pulsation. Howev ...

  • Omega Engineering FLR6000 series - page 7

    Schematics The transmitter can be wired in various configurations to allow interface with many different types of dat a col- lection and control instrumentation. Schematics 1 & 2 represent typical wiring for a target powered by either AC power or DC supply . Schematics 3 & 4 will be utilized when the flow trans- mitter is operated with loop ...

  • Omega Engineering FLR6000 series - page 8

    Inst alling the T ransmitter 1. Disconnect electrical power from the target sys- tem before making or changing any transmitter connections. 2. Use 0.05A fast acting fuse if non-current limited power sources are utilized. 3. T erminate cable shield connection at either DC ground or Earth ground. 4. Mount the transmitter so fluid is traveling in the ...

  • Omega Engineering FLR6000 series - page 9

    ENTER - The current tot al can be manually stored in the monitor's flash memory . Press and hold the ENTER key for 2 seconds. The display will respond with a flashing T OT ALSVD and then will return to RUN mode. RESET TOT AL - T o reset the monitor total display , press the MENU and ENTER keys simultaneously until TOT ALRST starts to flash. Th ...

  • Omega Engineering FLR6000 series - page 10

    Programming Procedures The FLR T ransmitter allows two basic sets of program- ming procedures: list item selection and entering numeric values. List Item Selection Procedure Note: If you are already in PROGRAM mode and the selection to be viewed or changed is already displayed, proceed to step 3 below. If you are in PROGRAM mode and the selection t ...

  • Omega Engineering FLR6000 series - page 11

    Programming Flow Chart The programming flow chart on pages 10 and 1 1 will aid understanding of the menu structure of the FLR Flow T ransmitter . It will also help with understanding the available configuration selections. Programming Descriptions Display Mode The meter can display RA TE (flow rate) or T OT AL (total accumulated flow) or alternate ...

  • Omega Engineering FLR6000 series - page 12

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 10 ...

  • Omega Engineering FLR6000 series - page 13

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 11 ...

  • Omega Engineering FLR6000 series - page 14

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 12 Zero Capture The zero position of the meter cone must be set when installing the meter . T o capture the zero calibration position, press ENTER at the ZERO CAP prompt. NO will display . Press either arrow key to change to YES, then press ENTER to capture zero. Meter T ype Th ...

  • Omega Engineering FLR6000 series - page 15

    Output Mode The FLR Flow T ransmitter offers three analog output modes: • 4–20 mA Output Signal • 0–5 V olts DC Output Signal • 0–10 V olts DC Output Signal The output mode selected is determined by the type of peripheral device being connected to the FLR Flow T ransmitter . The displayed name is OUT MODE and is viewed or changed using ...

  • Omega Engineering FLR6000 series - page 16

    Password Password protection prevents unauthorized users from changing programming information. Initially the pass- word is set to all zeros. Its displayed name is P ASSWORD and is viewed or changed using the Numeric V alue Entry Procedure found on page 8. Restore Defaults This feature allows you to restore factory calibration data. Its displayed n ...

  • Omega Engineering FLR6000 series - page 17

    Inspection 1. Frequent inspection should be made. The envi- ronment and frequency of use should determine a schedule for maintenance checks. It is recom- mended that it should be at least once a year . 2. Perform visual, electrical, and mechanical checks on all components on a regular basis. 3. Visually check for undue heating evidence such as disc ...

  • Omega Engineering FLR6000 series - page 18

    Application Information – Pneumatic NOTE: Pressure and temperature readings must be taken at the flow transmitter inlet to ensure accurate correction factors. The pneumatic flow transmitter is calibrated for air in standard cubic feet per minute (scfm) at 1.0 s.g. (70 ° F @ 100 psi), and liters per second (lps) at 1.0 s.g. (21 ° C @ 6.9 bar). F ...

  • Omega Engineering FLR6000 series - page 19

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 17 Water Based Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5 4-4 3-30 2-20 FL ...

  • Omega Engineering FLR6000 series - page 20

    FLR Flow T ransmitter Inst allation & Programming Instructions Water FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .02 -.20 .05-.50 .10-1.0 .20-2.0 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.2-2.0 0.1-1.0 0.5-5.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4" / 1" 0.5-5.0 0.2-2.0 1-10 5-50 4-40 3-30 2-20 ...

  • Omega Engineering FLR6000 series - page 21

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 19 Petroleum Fluids FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 .05-.50 .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 3/4"/ 1" 5-50 4-40 3-30 2-20 0 0 ...

  • Omega Engineering FLR6000 series - page 22

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 20 Phosphate Ester FLOW , GPM I S P , P O R D E R U S S E R P 1/4" .20-2.0 .10-1.0 0.0 0 2 4 6 0.5 .05-.5O .02-.20 FLOW , GPM I S P , P O R D E R U S S E R P 1/2" 1-15 1-10 0.5-5.0 0 1 2 2.5 0 2 4 0.2-2.0 0.1-1.0 FLOW , GPM I S P , P O R D E R U S S E R P 1-1/4" ...

  • Omega Engineering FLR6000 series - page 23

    FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , SCFM I S P , P O R D E R U S S E R P 3/4"/1" 15-150 10-100 5-25 5-50 25-250 FLO W , SCFM 1-1/4"/1 - 1/2" 20-200 40-400 60-600 80-800 100-1000 I S P , P O R D E R U S S E R P FLR ...

  • Omega Engineering FLR6000 series - page 24

    FLR Flow T ransmitter Inst allation & Programming Instructions Page 22 Air / Compressed Gases FLO W , SCFM D I S P , L A I T N E R E F F I D E R U S S E R P 100-1400 200-2200 3" FLO W , SCFM I S P , P O R D E R U S S E R P 1/4" 3-30 2-20 1-10 0.5-5 FLO W , SCFM I S P , P O R D E R U S S E R P 1/2" 10-100 5-50 2-25 15-150 FLO W , ...

  • Omega Engineering FLR6000 series - page 25

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 23 ...

  • Omega Engineering FLR6000 series - page 26

    FLR Flow T ransmitter Inst allation & Programming Instructions NOTES: Page 24 ...

  • Omega Engineering FLR6000 series - page 27

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega Engineering FLR6000 series - page 28

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com M4183/0405 TEMPERA TURE 䡺 ⻬ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ W ire: Thermocouple, R TD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Co ...

Fabbricante Omega Engineering Categoria Marine Sanitation System

I documenti che otteniamo dal fabbricante del dispositivoOmega Engineering FLR6000 series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega Engineering
- manuali per l’uso FLR6000 series
- schede prodotto Omega Engineering
- opuscoli
- o etichette energetiche Omega Engineering FLR6000 series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega Engineering FLR6000 series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega Engineering FLR6000 series, manuali di manutenzione, brevi manuali o manuali utente Omega Engineering FLR6000 series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega Engineering FLR6000 series.

Manuale completo del dispositivo Omega Engineering FLR6000 series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega Engineering FLR6000 series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega Engineering FLR6000 series.

Il manuale per l’uso completo Omega Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega Engineering FLR6000 series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega Engineering FLR6000 series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega Engineering FLR6000 series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega Engineering FLR6000 series - che ci dovrebbe aiutare nei primi passi durante l'uso Omega Engineering FLR6000 series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega Engineering FLR6000 series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega Engineering FLR6000 series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega Engineering FLR6000 series?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega Engineering FLR6000 series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega Engineering FLR6000 series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)