    61225001L1-5D 1 Express 6530 SHDSL NxNTU Installation and Maintenance Section 61225001L1-5D Issue 4, October 2002 CONTENTS 1. GENERAL ..................................................................... 1 2. CONNECTIONS ........................................................... 4 3. OPTIONING ...................................................... ...

  • ADTRAN Express 6530 6530 - page 2

    2 61225001L1-5D The Express 6530 can be powered from any AC power source ranging from 90 V to 240 V at frequencies of 50 Hz to 60 Hz, or a nominal -48 VDC power source. The SHDSL NTU will be used to provide access to customer premises to E1 or Nx64K leased-line services, as well as primary-rate ISDN. The SHDSL NTU is required to support leased-line ...

  • ADTRAN Express 6530 6530 - page 3

    61225001L1-5D 3 The Express 6530 has four front panel pushbuttons. The buttons are protected from accidental operation. The front panel button functions can be disabled via the management interface. It is possible to disable the port select SHDSL option to avoid the possibility of looping the SHDSL port when disabled. Table 2 lists and describes th ...

  • ADTRAN Express 6530 6530 - page 4

    4 61225001L1-5D 2. CONNECTIONS Back Panel Features The back panel of the Express 6530 SHDSL NxNTU is illustrated in Figure 3 . The SHDSL port uses a RJ-45 connector with the interchange circuits and pinouts listed in Table 3 . Table 3. SHDSL Pin Connections e m a N e g n a h c r e t n In o i t p i r c s e Dt u o n i P C / Nn o i t c e n n o C o N3 ...

  • ADTRAN Express 6530 6530 - page 5

    61225001L1-5D 5 The local management port is a DB-9 female connector and is labeled V.28. The interchange circuits and pinouts are listed in Table 5 . The local management baud rate will auto-detect between 2400 baud and 57600 baud. See EIA-574, Sec 2.2 and Figure 2.7, with Receive Data, Transmit Data and Signal Ground only. The other pins are inte ...

  • ADTRAN Express 6530 6530 - page 6

    6 61225001L1-5D Table 7 defines the V.35 port pin connections. Table 8 defines the V.36 port pin connections. r e b m u N t i u c r i Ce m a N t i u c r i CE C D m o r F / o T) B / A ( t u o n i P 2 0 1d n u o r G l a n g i SB 3 - 2 0 1a t a D t i m s n a r TO TS / P 4 0 1a t a D e v i e c e RM O R FT / R 5 0 1d n e S o t t s e u q e RO TC 6 0 1d n ...

  • ADTRAN Express 6530 6530 - page 7

    61225001L1-5D 7 3. OPTIONING Hardware Optioning The strap map for the Express 6530 SHDSL NxNTU is illustrated in Figure 4 . Figure 4. Express 6530 Strap Map ...

  • ADTRAN Express 6530 6530 - page 8

    8 61225001L1-5D Figure 5. Express 6530 Menu Tree Software Optioning The menu tree in Figure 5 illustrates the path to every provisioning, performance monitoring, and test access point in the Express 6530 menu system. 1. Unit Information Main Menu 2. Provisioning 2. L T 1. NT 1. PN127 2. V .54 2. Disable 1. Enable 1. -15. Threshold in dB 0. Disabled ...

  • ADTRAN Express 6530 6530 - page 9

    61225001L1-5D 9 Cross-Connect Map The purpose of the cross-connect map is to allocate the time slots (TS0s) from the SHDSL loop to user ports (E1, V.35/X.21) and configure framing. The cross-connect maps can be accessed via the VT100 terminal screens. Select “1,” Provisioning , from the Main Menu. Choose to provision the local unit (Selection 1 ...

  • ADTRAN Express 6530 6530 - page 10

    10 61225001L1-5D G. Full G.703 Service If this quick key command is selected, the cross- connect map will automatically configure the time slots for Full G.703 service, and the framing will be set for transparent. Refer to the Typical Applications subsection for more information. N. Full Nx64K Service If this quick key command is selected, the cros ...

  • ADTRAN Express 6530 6530 - page 11

    61225001L1-5D 11 Typical Applications Framed Full E1 Service is set up using the quick key “G,” and then selecting “A” to save the changes. The screen in Figure 8 illustrates a cross-connect map configured for Framed Full E1 Service. Unframed Full E1 Service is set up using the quick key “G,” entering “1” in both the SHDSL TS0 slot ...

  • ADTRAN Express 6530 6530 - page 12

    12 61225001L1-5D Full Nx64K 2 Mbps Service is set up using the quick key “N,” and then selecting “A” to save the changes. The screen in Figure 10 illustrates a cross-connect map configured for Full Nx64K 2 Mbps Service. In addition, when setting up Full Nx64K 2 Mbps Service, the type of line interface must be specified. V.35, V.36, or X.21 ...

  • ADTRAN Express 6530 6530 - page 13

    61225001L1-5D 13 Bit Error Rate Test The SHDSL NTU contains a built-in Bit Error Rate Test (BERT). The BERT involves injecting and detecting a Pseudorandom Binary Sequence (PRBS) toward the network on the selected payload (i.e. G.703, Nx64, or entire SHDSL payload). The PRBS used in the SHDSL NTU is PRS15 as defined in ITU-T O.150 and O.151. It is ...

  • ADTRAN Express 6530 6530 - page 14

    14 61225001L1-5D Local Customer Transparent Loopback – Provides a loopback at the NTU in the customer direction ( Figure 14 ). Data is passed transparently to the network side. Local Network Transparent Loopback – Provides a loopback at the NTU in the network direction ( Figure 18 ). Data is passed transparently to the customer side. Figure 14. ...

  • ADTRAN Express 6530 6530 - page 15

    61225001L1-5D 15 Loopbacks may be initiated via the VT100 test screens, front panel pushbuttons, Nx64K port control leads, or by receiving V.54 or PN127 in-band looping signals. Not all loopback types are available for all ports and port services by all initiating sources. See Table 9 for an overview. A key to the symbols displayed in the Table 9 i ...

  • ADTRAN Express 6530 6530 - page 16

    16 61225001L1-5D Multiple Services The NTU supports the configuration of multiple services. These services are routed to either the G.703/G.704 interface or the Nx64K interface. The Nx64K interface supports a single service with 1 <= N <= 36. The G.703 interface (with G.704 framing) supports multiple services (often termed “Stacked E1”). ...

  • ADTRAN Express 6530 6530 - page 17

    61225001L1-5D 17 The NTU provides framing on the E1 port as described in G.704 (sections 2.3 and 5) and G.706 (section 4) and G.736. In this mode, the data arriving at the SHDSL interface need not contain any G.704 framing and the NTU generates the framing. One or more services can be routed into time slots 1-31. CRC-4 multiframe may be enabled or ...

  • ADTRAN Express 6530 6530 - page 18

    18 61225001L1-5D 4. SPECIFICATIONS Table 10 lists the specifications for the Express 6530 SHDSL NxNTU. Network Interface Line Rate:. ............................................................ SHDSL per ITU G.991.2 Line Code: ............................................................ TC PAM Connector: ............................................ ...

  • ADTRAN Express 6530 6530 - page 19

    61225001L1-5D 19 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five (5) years from the date of shipment if it does not meet its published specifications or fails while in service. Refer to ADTRAN International Equipment Warranty , Document: 60000003#I-3. Contact Customer and Product Service (CAPS) prior to retur ...

  • ADTRAN Express 6530 6530 - page 20

    20 61225001L1-5D ...

Fabricante ADTRAN Categoría Network Card

Los documentos del dispositivo ADTRAN Express 6530 6530 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ADTRAN
- manuales de instrucciones Express 6530 6530
- hojas de producto ADTRAN
- folletos informativos
- o etiquetas energéticas ADTRAN Express 6530 6530
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ADTRAN Express 6530 6530.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ADTRAN Express 6530 6530, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ADTRAN Express 6530 6530. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ADTRAN Express 6530 6530.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ADTRAN Express 6530 6530, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ADTRAN Express 6530 6530. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ADTRAN Express 6530 6530.

El manual de instrucciones completo de ADTRAN debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ADTRAN Express 6530 6530 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ADTRAN Express 6530 6530, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ADTRAN Express 6530 6530 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ADTRAN Express 6530 6530 - que deben facilitarnos los primeros pasos durante el uso de ADTRAN Express 6530 6530
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ADTRAN Express 6530 6530
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ADTRAN Express 6530 6530 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ADTRAN Express 6530 6530?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ADTRAN Express 6530 6530, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ADTRAN Express 6530 6530 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)