Manuale per l’uso ADTRAN Express 6530 6530

20 pagine 8.02 mb
Scarica

Vai alla pagina of 20

Summary
  • ADTRAN Express 6530 6530 - page 1

    61225001L1-5D 1 Express 6530 SHDSL NxNTU Installation and Maintenance Section 61225001L1-5D Issue 4, October 2002 CONTENTS 1. GENERAL ..................................................................... 1 2. CONNECTIONS ........................................................... 4 3. OPTIONING ...................................................... ...

  • ADTRAN Express 6530 6530 - page 2

    2 61225001L1-5D The Express 6530 can be powered from any AC power source ranging from 90 V to 240 V at frequencies of 50 Hz to 60 Hz, or a nominal -48 VDC power source. The SHDSL NTU will be used to provide access to customer premises to E1 or Nx64K leased-line services, as well as primary-rate ISDN. The SHDSL NTU is required to support leased-line ...

  • ADTRAN Express 6530 6530 - page 3

    61225001L1-5D 3 The Express 6530 has four front panel pushbuttons. The buttons are protected from accidental operation. The front panel button functions can be disabled via the management interface. It is possible to disable the port select SHDSL option to avoid the possibility of looping the SHDSL port when disabled. Table 2 lists and describes th ...

  • ADTRAN Express 6530 6530 - page 4

    4 61225001L1-5D 2. CONNECTIONS Back Panel Features The back panel of the Express 6530 SHDSL NxNTU is illustrated in Figure 3 . The SHDSL port uses a RJ-45 connector with the interchange circuits and pinouts listed in Table 3 . Table 3. SHDSL Pin Connections e m a N e g n a h c r e t n In o i t p i r c s e Dt u o n i P C / Nn o i t c e n n o C o N3 ...

  • ADTRAN Express 6530 6530 - page 5

    61225001L1-5D 5 The local management port is a DB-9 female connector and is labeled V.28. The interchange circuits and pinouts are listed in Table 5 . The local management baud rate will auto-detect between 2400 baud and 57600 baud. See EIA-574, Sec 2.2 and Figure 2.7, with Receive Data, Transmit Data and Signal Ground only. The other pins are inte ...

  • ADTRAN Express 6530 6530 - page 6

    6 61225001L1-5D Table 7 defines the V.35 port pin connections. Table 8 defines the V.36 port pin connections. r e b m u N t i u c r i Ce m a N t i u c r i CE C D m o r F / o T) B / A ( t u o n i P 2 0 1d n u o r G l a n g i SB 3 - 2 0 1a t a D t i m s n a r TO TS / P 4 0 1a t a D e v i e c e RM O R FT / R 5 0 1d n e S o t t s e u q e RO TC 6 0 1d n ...

  • ADTRAN Express 6530 6530 - page 7

    61225001L1-5D 7 3. OPTIONING Hardware Optioning The strap map for the Express 6530 SHDSL NxNTU is illustrated in Figure 4 . Figure 4. Express 6530 Strap Map ...

  • ADTRAN Express 6530 6530 - page 8

    8 61225001L1-5D Figure 5. Express 6530 Menu Tree Software Optioning The menu tree in Figure 5 illustrates the path to every provisioning, performance monitoring, and test access point in the Express 6530 menu system. 1. Unit Information Main Menu 2. Provisioning 2. L T 1. NT 1. PN127 2. V .54 2. Disable 1. Enable 1. -15. Threshold in dB 0. Disabled ...

  • ADTRAN Express 6530 6530 - page 9

    61225001L1-5D 9 Cross-Connect Map The purpose of the cross-connect map is to allocate the time slots (TS0s) from the SHDSL loop to user ports (E1, V.35/X.21) and configure framing. The cross-connect maps can be accessed via the VT100 terminal screens. Select “1,” Provisioning , from the Main Menu. Choose to provision the local unit (Selection 1 ...

  • ADTRAN Express 6530 6530 - page 10

    10 61225001L1-5D G. Full G.703 Service If this quick key command is selected, the cross- connect map will automatically configure the time slots for Full G.703 service, and the framing will be set for transparent. Refer to the Typical Applications subsection for more information. N. Full Nx64K Service If this quick key command is selected, the cros ...

  • ADTRAN Express 6530 6530 - page 11

    61225001L1-5D 11 Typical Applications Framed Full E1 Service is set up using the quick key “G,” and then selecting “A” to save the changes. The screen in Figure 8 illustrates a cross-connect map configured for Framed Full E1 Service. Unframed Full E1 Service is set up using the quick key “G,” entering “1” in both the SHDSL TS0 slot ...

  • ADTRAN Express 6530 6530 - page 12

    12 61225001L1-5D Full Nx64K 2 Mbps Service is set up using the quick key “N,” and then selecting “A” to save the changes. The screen in Figure 10 illustrates a cross-connect map configured for Full Nx64K 2 Mbps Service. In addition, when setting up Full Nx64K 2 Mbps Service, the type of line interface must be specified. V.35, V.36, or X.21 ...

  • ADTRAN Express 6530 6530 - page 13

    61225001L1-5D 13 Bit Error Rate Test The SHDSL NTU contains a built-in Bit Error Rate Test (BERT). The BERT involves injecting and detecting a Pseudorandom Binary Sequence (PRBS) toward the network on the selected payload (i.e. G.703, Nx64, or entire SHDSL payload). The PRBS used in the SHDSL NTU is PRS15 as defined in ITU-T O.150 and O.151. It is ...

  • ADTRAN Express 6530 6530 - page 14

    14 61225001L1-5D Local Customer Transparent Loopback – Provides a loopback at the NTU in the customer direction ( Figure 14 ). Data is passed transparently to the network side. Local Network Transparent Loopback – Provides a loopback at the NTU in the network direction ( Figure 18 ). Data is passed transparently to the customer side. Figure 14. ...

  • ADTRAN Express 6530 6530 - page 15

    61225001L1-5D 15 Loopbacks may be initiated via the VT100 test screens, front panel pushbuttons, Nx64K port control leads, or by receiving V.54 or PN127 in-band looping signals. Not all loopback types are available for all ports and port services by all initiating sources. See Table 9 for an overview. A key to the symbols displayed in the Table 9 i ...

  • ADTRAN Express 6530 6530 - page 16

    16 61225001L1-5D Multiple Services The NTU supports the configuration of multiple services. These services are routed to either the G.703/G.704 interface or the Nx64K interface. The Nx64K interface supports a single service with 1 <= N <= 36. The G.703 interface (with G.704 framing) supports multiple services (often termed “Stacked E1”). ...

  • ADTRAN Express 6530 6530 - page 17

    61225001L1-5D 17 The NTU provides framing on the E1 port as described in G.704 (sections 2.3 and 5) and G.706 (section 4) and G.736. In this mode, the data arriving at the SHDSL interface need not contain any G.704 framing and the NTU generates the framing. One or more services can be routed into time slots 1-31. CRC-4 multiframe may be enabled or ...

  • ADTRAN Express 6530 6530 - page 18

    18 61225001L1-5D 4. SPECIFICATIONS Table 10 lists the specifications for the Express 6530 SHDSL NxNTU. Network Interface Line Rate:. ............................................................ SHDSL per ITU G.991.2 Line Code: ............................................................ TC PAM Connector: ............................................ ...

  • ADTRAN Express 6530 6530 - page 19

    61225001L1-5D 19 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five (5) years from the date of shipment if it does not meet its published specifications or fails while in service. Refer to ADTRAN International Equipment Warranty , Document: 60000003#I-3. Contact Customer and Product Service (CAPS) prior to retur ...

  • ADTRAN Express 6530 6530 - page 20

    20 61225001L1-5D ...

Fabbricante ADTRAN Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoADTRAN Express 6530 6530 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ADTRAN
- manuali per l’uso Express 6530 6530
- schede prodotto ADTRAN
- opuscoli
- o etichette energetiche ADTRAN Express 6530 6530
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ADTRAN Express 6530 6530.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ADTRAN Express 6530 6530, manuali di manutenzione, brevi manuali o manuali utente ADTRAN Express 6530 6530. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ADTRAN Express 6530 6530.

Manuali per l’uso simili

Manuale completo del dispositivo ADTRAN Express 6530 6530, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ADTRAN Express 6530 6530 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ADTRAN Express 6530 6530.

Il manuale per l’uso completo ADTRAN, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ADTRAN Express 6530 6530 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ADTRAN Express 6530 6530, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ADTRAN Express 6530 6530 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ADTRAN Express 6530 6530 - che ci dovrebbe aiutare nei primi passi durante l'uso ADTRAN Express 6530 6530
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ADTRAN Express 6530 6530
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio ADTRAN Express 6530 6530 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su ADTRAN Express 6530 6530?

Utilizza il modulo sottostante

Se non hai risolto il problema con ADTRAN Express 6530 6530 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con ADTRAN Express 6530 6530 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)