    61225001L1-5D 1 Express 6530 SHDSL NxNTU Installation and Maintenance Section 61225001L1-5D Issue 4, October 2002 CONTENTS 1. GENERAL ..................................................................... 1 2. CONNECTIONS ........................................................... 4 3. OPTIONING ...................................................... ...

  • ADTRAN Express 6530 6530 - page 2

    2 61225001L1-5D The Express 6530 can be powered from any AC power source ranging from 90 V to 240 V at frequencies of 50 Hz to 60 Hz, or a nominal -48 VDC power source. The SHDSL NTU will be used to provide access to customer premises to E1 or Nx64K leased-line services, as well as primary-rate ISDN. The SHDSL NTU is required to support leased-line ...

  • ADTRAN Express 6530 6530 - page 3

    61225001L1-5D 3 The Express 6530 has four front panel pushbuttons. The buttons are protected from accidental operation. The front panel button functions can be disabled via the management interface. It is possible to disable the port select SHDSL option to avoid the possibility of looping the SHDSL port when disabled. Table 2 lists and describes th ...

  • ADTRAN Express 6530 6530 - page 4

    4 61225001L1-5D 2. CONNECTIONS Back Panel Features The back panel of the Express 6530 SHDSL NxNTU is illustrated in Figure 3 . The SHDSL port uses a RJ-45 connector with the interchange circuits and pinouts listed in Table 3 . Table 3. SHDSL Pin Connections e m a N e g n a h c r e t n In o i t p i r c s e Dt u o n i P C / Nn o i t c e n n o C o N3 ...

  • ADTRAN Express 6530 6530 - page 5

    61225001L1-5D 5 The local management port is a DB-9 female connector and is labeled V.28. The interchange circuits and pinouts are listed in Table 5 . The local management baud rate will auto-detect between 2400 baud and 57600 baud. See EIA-574, Sec 2.2 and Figure 2.7, with Receive Data, Transmit Data and Signal Ground only. The other pins are inte ...

  • ADTRAN Express 6530 6530 - page 6

    6 61225001L1-5D Table 7 defines the V.35 port pin connections. Table 8 defines the V.36 port pin connections. r e b m u N t i u c r i Ce m a N t i u c r i CE C D m o r F / o T) B / A ( t u o n i P 2 0 1d n u o r G l a n g i SB 3 - 2 0 1a t a D t i m s n a r TO TS / P 4 0 1a t a D e v i e c e RM O R FT / R 5 0 1d n e S o t t s e u q e RO TC 6 0 1d n ...

  • ADTRAN Express 6530 6530 - page 7

    61225001L1-5D 7 3. OPTIONING Hardware Optioning The strap map for the Express 6530 SHDSL NxNTU is illustrated in Figure 4 . Figure 4. Express 6530 Strap Map ...

  • ADTRAN Express 6530 6530 - page 8

    8 61225001L1-5D Figure 5. Express 6530 Menu Tree Software Optioning The menu tree in Figure 5 illustrates the path to every provisioning, performance monitoring, and test access point in the Express 6530 menu system. 1. Unit Information Main Menu 2. Provisioning 2. L T 1. NT 1. PN127 2. V .54 2. Disable 1. Enable 1. -15. Threshold in dB 0. Disabled ...

  • ADTRAN Express 6530 6530 - page 9

    61225001L1-5D 9 Cross-Connect Map The purpose of the cross-connect map is to allocate the time slots (TS0s) from the SHDSL loop to user ports (E1, V.35/X.21) and configure framing. The cross-connect maps can be accessed via the VT100 terminal screens. Select “1,” Provisioning , from the Main Menu. Choose to provision the local unit (Selection 1 ...

  • ADTRAN Express 6530 6530 - page 10

    10 61225001L1-5D G. Full G.703 Service If this quick key command is selected, the cross- connect map will automatically configure the time slots for Full G.703 service, and the framing will be set for transparent. Refer to the Typical Applications subsection for more information. N. Full Nx64K Service If this quick key command is selected, the cros ...

  • ADTRAN Express 6530 6530 - page 11

    61225001L1-5D 11 Typical Applications Framed Full E1 Service is set up using the quick key “G,” and then selecting “A” to save the changes. The screen in Figure 8 illustrates a cross-connect map configured for Framed Full E1 Service. Unframed Full E1 Service is set up using the quick key “G,” entering “1” in both the SHDSL TS0 slot ...

  • ADTRAN Express 6530 6530 - page 12

    12 61225001L1-5D Full Nx64K 2 Mbps Service is set up using the quick key “N,” and then selecting “A” to save the changes. The screen in Figure 10 illustrates a cross-connect map configured for Full Nx64K 2 Mbps Service. In addition, when setting up Full Nx64K 2 Mbps Service, the type of line interface must be specified. V.35, V.36, or X.21 ...

  • ADTRAN Express 6530 6530 - page 13

    61225001L1-5D 13 Bit Error Rate Test The SHDSL NTU contains a built-in Bit Error Rate Test (BERT). The BERT involves injecting and detecting a Pseudorandom Binary Sequence (PRBS) toward the network on the selected payload (i.e. G.703, Nx64, or entire SHDSL payload). The PRBS used in the SHDSL NTU is PRS15 as defined in ITU-T O.150 and O.151. It is ...

  • ADTRAN Express 6530 6530 - page 14

    14 61225001L1-5D Local Customer Transparent Loopback – Provides a loopback at the NTU in the customer direction ( Figure 14 ). Data is passed transparently to the network side. Local Network Transparent Loopback – Provides a loopback at the NTU in the network direction ( Figure 18 ). Data is passed transparently to the customer side. Figure 14. ...

  • ADTRAN Express 6530 6530 - page 15

    61225001L1-5D 15 Loopbacks may be initiated via the VT100 test screens, front panel pushbuttons, Nx64K port control leads, or by receiving V.54 or PN127 in-band looping signals. Not all loopback types are available for all ports and port services by all initiating sources. See Table 9 for an overview. A key to the symbols displayed in the Table 9 i ...

  • ADTRAN Express 6530 6530 - page 16

    16 61225001L1-5D Multiple Services The NTU supports the configuration of multiple services. These services are routed to either the G.703/G.704 interface or the Nx64K interface. The Nx64K interface supports a single service with 1 <= N <= 36. The G.703 interface (with G.704 framing) supports multiple services (often termed “Stacked E1”). ...

  • ADTRAN Express 6530 6530 - page 17

    61225001L1-5D 17 The NTU provides framing on the E1 port as described in G.704 (sections 2.3 and 5) and G.706 (section 4) and G.736. In this mode, the data arriving at the SHDSL interface need not contain any G.704 framing and the NTU generates the framing. One or more services can be routed into time slots 1-31. CRC-4 multiframe may be enabled or ...

  • ADTRAN Express 6530 6530 - page 18

    18 61225001L1-5D 4. SPECIFICATIONS Table 10 lists the specifications for the Express 6530 SHDSL NxNTU. Network Interface Line Rate:. ............................................................ SHDSL per ITU G.991.2 Line Code: ............................................................ TC PAM Connector: ............................................ ...

  • ADTRAN Express 6530 6530 - page 19

    61225001L1-5D 19 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five (5) years from the date of shipment if it does not meet its published specifications or fails while in service. Refer to ADTRAN International Equipment Warranty , Document: 60000003#I-3. Contact Customer and Product Service (CAPS) prior to retur ...

  • ADTRAN Express 6530 6530 - page 20

    20 61225001L1-5D ...

メーカー ADTRAN カテゴリー Network Card

ADTRAN Express 6530 6530のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Express 6530 6530の取扱説明書
- ADTRANの製品カード
- パンフレット
- またはADTRAN Express 6530 6530の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ADTRAN Express 6530 6530の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ADTRAN Express 6530 6530の取り付け説明書、サービスマニュアル、簡易説明書、またはADTRAN Express 6530 6530のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ADTRAN Express 6530 6530の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ADTRAN Express 6530 6530デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがADTRAN Express 6530 6530を使用するのを助ける技術的文書のことです。説明書は通常、全てのADTRAN Express 6530 6530ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ADTRANの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ADTRAN Express 6530 6530の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははADTRAN Express 6530 6530の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ADTRAN Express 6530 6530に関してこのドキュメントで見つけることができる全てのヒントの目次
3. ADTRAN Express 6530 6530デバイスの基本機能を使うにあたってのヒント。 ADTRAN Express 6530 6530のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ADTRAN Express 6530 6530に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるADTRAN Express 6530 6530のメーカー/サービスへの連絡先に関する情報。

ADTRAN Express 6530 6530についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもADTRAN Express 6530 6530の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがADTRAN Express 6530 6530で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)