Manuel d’utilisation Beckett CF500

16 pages 1.21 mb
Télécharger

Aller à la page of 16

Summary
  • Beckett CF500 - page 1

    6104 BCF5 R06 Page 1 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner : Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work. ...

  • Beckett CF500 - page 2

    Page 2 6104 BCF5 R06 T able of Contents General Information .............................................................................................................................. . 3-4 T o the Owner ............................................................................................................................................... ...

  • Beckett CF500 - page 3

    6104 BCF5 R06 Page 3 Hazar d de fi nitions Intended to bring special attention to information, but not related to personal injury or property damage. NO TICE Indicates a potentially hazardous situation, which, if not avoided, may result in person- al injury or property damage. Indicates a potentially hazardous situation, which, if not avoided, cou ...

  • Beckett CF500 - page 4

    Page 4 6104 BCF5 R06 Owner ’ s Responsibility: Follow These Instructions Exactly Contact a professional, quali fi ed service agency for the installation, adjustment and service of your oil burning system. Thereafter , have your equipment adjusted and inspected at least annually to ensure reliable operation. This work requires technical training, ...

  • Beckett CF500 - page 5

    6104 BCF5 R06 Page 5 Combustion air supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protec- tion Standard for Oil-Burning Equipment, NFP A 31. For appliance/burner units in con fi ned spaces, the room must have an air opening n ...

  • Beckett CF500 - page 6

    Page 6 6104 BCF5 R06 Figure 1. Min. Combustion Chamber Dimensions V erify fi ring rate Refer to appliance manufacturer ’ s instructions (if available) for fi ring rate and nozzle selection. Otherwise, the maximum recommended fi ring rate for the burner depends on the length of the fi ring chamber and the distance from the burner center to the ...

  • Beckett CF500 - page 7

    6104 BCF5 R06 Page 7 Mount the bur ner Mount fl ange(s) on air tube This section does not apply to burners with welded fl ang- es. Do not install air tube on burner . For non-pr essure fi ring fl ange , refer to Figure 3 : Install gasket (item a ) and fl ange (item d ). Ignore the next paragraph. For pr essur e- fi ring fl ange , refer to Fi ...

  • Beckett CF500 - page 8

    Page 8 6104 BCF5 R06 Install nozzle line assembl y Insert the nozzle line assembly into the burner air tube. Reference Figure 5 . Slide the secondary adjusting plate ( Figure 6 , item f ) com- pletely to the left on the indicator adjusting plate (item e ). Finger tighten acorn nut (item c ) to secure the two plates together . Slide both plates comp ...

  • Beckett CF500 - page 9

    6104 BCF5 R06 Page 9 The burner is shipped without the by-pass plug in- stalled. Intall the by-pass plug in two-pipe oil supply systems ONL Y . y y Failure to comply could cause immediate pump seal failure, pressurized oil leakage and the po- tential for a fi re and injury hazard. Do Not Install By-pass Plug with 1-Pipe System Install the oil tank ...

  • Beckett CF500 - page 10

    Page 10 6104 BCF5 R06 W ir e the bur ner — R7184 Disconnect electrical power before installing or servic- ing the burner . Provide ground wiring to the burner , metal control en- closures and accessories. (This may also be required to aid proper control system operation) Perform all wiring in compliance with the National Electric Code ANSI/NFP A ...

  • Beckett CF500 - page 11

    6104 BCF5 R06 Page 1 1 Star t-up chec klist Combustion air supply and venting have been inspected and veri fi ed to be free of obstructions and installed in ac- cordance with all applicable codes. Oil nozzle has been selected correctly and securely in- stalled in the nozzle adapter . Fuel unit by-pass plug has not been installed for one- pipe oil ...

  • Beckett CF500 - page 12

    Page 12 6104 BCF5 R06 Star t the Bur ner Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is very hot. Do not attempt to re-establish fl ame with the burner running if the fl ame becomes extinguished during start- up, venting, or adjustment. V apor ...

  • Beckett CF500 - page 13

    6104 BCF5 R06 Page 13 Set combustion using instr uments Allow the burner to run for approximately 5 to 10 min- utes. Set the stack or over- fi re draft to the level speci fi ed by the appliance manufacturer . Natural Draft Applications; typically over- fi re draft is -0.01” or -0.02” w .c. Direct V enting ; typically may not require draft ad ...

  • Beckett CF500 - page 14

    Page 14 6104 BCF5 R06 Maintenance and Ser vice Do not tamper with the burner or controls or make any adjustments unless you are a trained and quali fi ed service technician. T o ensure continued reliable operation, a quali fi ed service technician must service this burner annually . More frequent service intervals may be required in dusty or adve ...

  • Beckett CF500 - page 15

    6104 BCF5 R06 Page 15 R eplacement par ts 1 2 3 10 9 8 4 5 6 7 11 12 13 15 14 16 Item Part Name/Description Part Number 1 Air T ube Specify 2 Spline Nut 3666 3 Adjusting plate assembly 51286U 4 Blocking Oil Solenoid V alve 2182602U 5 Igniter 51771U 6 Control Specify 7 Air Band 3819 8 Air Shutter 3215 9 Fuel Pump Specify 10 Fuel lines Specify Length ...

  • Beckett CF500 - page 16

    Page 16 6104 BCF5 R06 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship under ...

Fabricant Beckett Catégorie Burner

Les documents que nous recevons du fabricant de l'appareilBeckett CF500 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Beckett
- manuels d’utilisations CF500
- fiches produit Beckett
- dépliants
- ou étiquettes-énergie Beckett CF500
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Beckett CF500.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Beckett CF500, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Beckett CF500. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Beckett CF500.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Beckett CF500, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Beckett CF500 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Beckett CF500.

Le manuel d’utilisation complet Beckett, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Beckett CF500 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Beckett CF500, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBeckett CF500 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Beckett CF500 - qui devraient nous aider dans les premières étapes lors de l'utilisation Beckett CF500
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Beckett CF500
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Beckett CF500 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Beckett CF500?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Beckett CF500, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Beckett CF500 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image